Issue Section:
Errata
Correction to the definition of the imbalance mass required to correct a disk skew as reported on page 459. The equation was stated correctly, the explanation of the term was in error. where,
= runout from dial indicator, in.
= axial separation of balance weights, symmetric to disk centerline, in.
= couple unbalance mass required to counteract or to simulate a skew,
= diameter of disk, in.
= diameter where skew was measured, in.
= diameter of balance weight circle, in.
= disk weight,