Heat-flux measurements are presented for a one-and-one-half stage high-pressure turbine operating at design-corrected conditions with modulated cooling flows in the presence of different inlet temperature profiles. Coolant is supplied from a heavily film-cooled vane and the purge cavity (between the rotor disk and the upstream vane) but not from the rotor blades, which are solid metal. Thin-film heat-flux gauges are located on the uncooled blade pressure and suction surface (at multiple span locations), on the blade tip, on the blade platform, and on the disk and vane sides of the purge cavity. These measurements provide a comprehensive picture of the effect of varying cooling flow rates on surface heat transfer to the turbine blade for uniform and radial inlet temperature profiles. Part I of this paper examines the macroscopic influence of varying all cooling flows together, while Part II investigates the individual regions of influence of the vane outer and purge cooling circuits in more detail. The heat-flux gauges are able to track the cooling flow over the suction surface of the airfoil as it wraps upwards along the base of the airfoil for the uniform vane inlet temperature profile. A similar comparison for the radial profile shows the same coolant behavior but with less pronounced changes. From these comparisons, it is clear that cooling impacts each temperature profile similarly. Nearly all of the cooling influence is limited to the blade suction surface, but small changes are observed for the pressure surface. In addition to the cooling study, a novel method of calculating the adiabatic wall temperature is demonstrated. The derived adiabatic wall temperature distribution shows very similar trends to the Stanton number distribution on the blade.
Skip Nav Destination
e-mail: mathison.4@osu.edu
e-mail: haldeman.5@osu.edu
e-mail: dunn.129@osu.edu
Article navigation
Research Papers
Heat Transfer for the Blade of a Cooled Stage and One-Half High-Pressure Turbine—Part I: Influence of Cooling Variation
R. M. Mathison,
R. M. Mathison
Gas Turbine Laboratory,
e-mail: mathison.4@osu.edu
Ohio State University
, 2300 West Case Road, Columbus, OH 43235
Search for other works by this author on:
C. W. Haldeman,
C. W. Haldeman
Gas Turbine Laboratory,
e-mail: haldeman.5@osu.edu
Ohio State University
, 2300 West Case Road, Columbus, OH 43235
Search for other works by this author on:
M. G. Dunn
M. G. Dunn
Gas Turbine Laboratory,
e-mail: dunn.129@osu.edu
Ohio State University
, 2300 West Case Road, Columbus, OH 43235
Search for other works by this author on:
R. M. Mathison
Gas Turbine Laboratory,
Ohio State University
, 2300 West Case Road, Columbus, OH 43235e-mail: mathison.4@osu.edu
C. W. Haldeman
Gas Turbine Laboratory,
Ohio State University
, 2300 West Case Road, Columbus, OH 43235e-mail: haldeman.5@osu.edu
M. G. Dunn
Gas Turbine Laboratory,
Ohio State University
, 2300 West Case Road, Columbus, OH 43235e-mail: dunn.129@osu.edu
J. Turbomach. May 2012, 134(3): 031014 (12 pages)
Published Online: July 15, 2011
Article history
Received:
August 17, 2010
Revised:
August 23, 2010
Online:
July 15, 2011
Published:
July 15, 2011
Citation
Mathison, R. M., Haldeman, C. W., and Dunn, M. G. (July 15, 2011). "Heat Transfer for the Blade of a Cooled Stage and One-Half High-Pressure Turbine—Part I: Influence of Cooling Variation." ASME. J. Turbomach. May 2012; 134(3): 031014. https://doi.org/10.1115/1.4003173
Download citation file:
Get Email Alerts
Related Articles
Film-Cooling Effectiveness on a Rotating Turbine Platform Using Pressure Sensitive Paint Technique
J. Turbomach (October,2010)
Estimating the Loss Associated With Film Cooling for a Turbine Stage
J. Turbomach (March,2012)
Related Proceedings Papers
Related Chapters
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Thermodynamic Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Introduction
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration