Comparative performance assessment and model validation of the linear Fresnel concentrator (LFC) and the conical solar reflector (CSR) systems were performed under identical operating and climatic conditions. This paper analyzes the amount of heat loss by convective heat transfer (natural or forced) from the receiver to ambient air with and without a glass-reinforced plastic sheet enclosure around the collector assembly. The matlab ordinary differential equation (ode) solvers were used for simulation of the transient states. Mathematical models were generated from energy balance equations of the glass cover, absorber pipe, heat transfer fluid, and storage tank for each system. Thermal and optical analyses of the LFC (with and without an enclosure) and CSR systems were carried out by using the measured and calculated results. Satisfactory agreement was found between the experimental data and predicted results. The given models are suitable to simulate the dynamic energy flow across the different components of the LFC and CSR systems.

References

1.
Blanco
,
J.
,
Malato
,
S.
,
Fernandez-Ibanez
,
P.
,
Alarcon
,
D.
,
Gernjak
,
W.
, and
Maldonado
,
M. L.
,
2009
, “
Review of Feasible Solar Energy Applications to Water Processes
,”
Renewable Sustainable Energy Rev.
,
13
(
6–7
), pp.
1437
1445
.
2.
Kalogirou
,
S. A.
,
2004
, “
Solar Thermal Collectors and Applications
,”
Prog. Energy Combust. Sci.
,
30
(
3
), pp.
231
295
.
3.
Montes
,
M. J.
,
Abánades
,
A.
, and
Martínez-Val
,
J. M.
,
2009
, “
Performance of a Direct Steam Generation Solar Thermal Power Plant for Electricity Production as a Function of the Solar Multiple
,”
Sol. Energy
,
83
(
5
), pp.
679
689
.
4.
Ryu
,
K.
,
Rhee
,
J.-G.
,
Park
,
K.-M.
, and
Kim
,
J.
,
2006
, “
Concept and Design of Modular Fresnel Lenses for Concentration Solar PV System
,”
Sol. Energy
,
80
(
12
), pp.
1580
1587
.
5.
Han
,
Y.
,
Wang
,
R.
,
Dai
,
Y.
, and
Xiong
,
A.
,
2007
, “
Studies on the Light Permeance Characteristic of a Fresnel Lens Group Applied in High Concentration Solar Energy
,”
J. Opt. A: Pure Appl. Opt.
,
9
(
11
), p.
988
.
6.
Brand
,
B.
,
Boudghene Stambouli
,
A.
, and
Zejli
,
D.
,
2012
, “
The Value of Dispatchability of CSP Plants in the Electricity Systems of Morocco and Algeria
,”
Energy Policy
,
47
, pp.
321
331
.
7.
Fernandez-Garcia
,
A.
,
Zarza
,
E.
,
Valenzuela
,
L.
, and
Pérez
,
M.
,
2010
, “
Parabolic-Trough Solar Collectors and Their Applications
,”
Renewable Sustainable Energy Rev.
,
14
(
7
), pp.
1695
1721
.
8.
Xie
,
W.
,
Dai
,
Y.
,
Wang
,
R.
, and
Sumathy
,
K.
,
2011
, “
Concentrated Solar Energy Applications Using Fresnel Lenses: A Review
,”
Renewable Sustainable Energy Rev.
,
15
(
6
), pp.
2588
2606
.
9.
Nkwetta
,
D. N.
,
Smyth
,
M.
,
Zacharopoulos
,
A.
, and
Hyde
,
T.
,
2012
, “
In-Door Experimental Analysis of Concentrated and Non-Concentrated Evacuated Tube Heat Pipe Collectors for Medium Temperature Applications
,”
Energy Build.
,
47
, pp.
674
681
.
10.
Xie
,
W. T.
,
Dai
,
Y. J.
, and
Wang
,
R. Z.
,
2013
, “
Thermal Performance Analysis of a Line-Focus Fresnel Lens Solar Collector Using Different Cavity Receivers
,”
Sol. Energy
,
91
, pp.
242
255
.
11.
Lin
,
M.
,
Sumathy
,
K.
,
Dai
,
Y. J.
,
Wang
,
R. Z.
, and
Chen
,
Y.
,
2013
, “
Experimental and Theoretical Analysis on a Linear Fresnel Reflector Solar Collector Prototype With V-Shaped Cavity Receiver
,”
Appl. Therm. Eng.
,
51
(
1–2
), pp.
963
972
.
12.
Imtiaz Hussain
,
M.
, and
Lee
,
G. H.
,
2015
, “
Experimental and Numerical Studies of a U-Shaped Solar Energy Collector to Track the Maximum CPV/T System Output by Varying the Flow Rate
,”
Renewable Energy
,
76
, pp.
735
742
.
13.
Wang
,
Y.
,
Liu
,
Q.
,
Lei
,
J.
, and
Jin
,
H.
,
2014
, “
A Three-Dimensional Simulation of a Parabolic Trough Solar Collector System Using Molten Salt as Heat Transfer Fluid
,”
Appl. Therm. Eng.
,
70
(
1
), pp.
462
476
.
14.
Lewandowski
,
A.
, and
Simms
,
D.
,
1987
, “
An Assessment of Linear Fresnel Lens Concentrators for Thermal Applications
,”
Energy
,
12
(
3–4
), pp.
333
338
.
15.
Xie
,
W. T.
,
Dai
,
Y. J.
, and
Wang
,
R. Z.
,
2011
, “
Numerical and Experimental Analysis of a Point Focus Solar Collector Using High Concentration Imaging PMMA Fresnel Lens
,”
Energy Convers. Manage.
,
52
(
6
), pp.
2417
2426
.
16.
Jeter
,
S. M.
,
1987
, “
Analytical Determination of the Optical Performance of Practical Parabolic Trough Collectors From Design Data
,”
Sol. Energy
,
39
(
1
), pp.
11
21
.
17.
Jeter
,
S. M.
,
1986
, “
Calculation of the Concentrated Flux Density Distribution in Parabolic Trough Collectors by a Semifinite Formulation
,”
Sol. Energy
,
37
(
5
), pp.
335
345
.
18.
Cheng
,
Z. D.
,
He
,
Y. L.
,
Cui
,
F. Q.
,
Xu
,
R. J.
, and
Tao
,
Y. B.
,
2012
, “
Numerical Simulation of a Parabolic Trough Solar Collector With Nonuniform Solar Flux Conditions by Coupling FVM and MCRT Method
,”
Sol. Energy
,
86
(
6
), pp.
1770
1784
.
19.
Toğrul
,
İ. T.
, and
Pehlivan
,
D.
,
2005
, “
Effect of Packing in the Airflow Passage on the Performance of a Solar Air-Heater With Conical Concentrator
,”
Appl. Therm. Eng.
,
25
(
8–9
), pp.
1349
1362
.
20.
Padilla
,
R. V.
,
Demirkaya
,
G.
,
Goswami
,
D. Y.
,
Stefanakos
,
E.
, and
Rahman
,
M. M.
,
2011
, “
Heat Transfer Analysis of Parabolic Trough Solar Receiver
,”
Appl. Energy
,
88
(
12
), pp.
5097
5110
.
21.
Imtiaz Hussain
,
M.
, and
Lee
,
G. H.
,
2014
, “
Thermal Performance Evaluation of a Conical Solar Water Heater Integrated With a Thermal Storage System
,”
Energy Convers. Manage.
,
87
, pp.
267
273
.
22.
Natarajan
,
S. K.
,
Mallick
,
T. K.
,
Katz
,
M.
, and
Weingaertner
,
S.
,
2011
, “
Numerical Investigations of Solar Cell Temperature for Photovoltaic Concentrator System With and Without Passive Cooling Arrangements
,”
Int. J. Therm. Sci.
,
50
(
12
), pp.
2514
2521
.
23.
Churchill
,
S. W.
, and
Chu
,
H. H.
,
1975
, “
Correlating Equations for Laminar and Turbulent Free Convection From a Horizontal Cylinder
,”
Int. J. Heat Mass Transfer
,
18
(
9
), pp.
1049
1053
.
24.
Stone
,
R.
,
1993
, “
Improved Statistical Procedure for the Evaluation of Solar Radiation Estimation Models
,”
Sol. Energy
,
51
(
4
), pp.
289
291
.
25.
Kim
,
D. H.
,
Jenkins
,
B. M.
,
Rumsey
,
T. R.
,
Yore
,
M. W.
, and
Kim
,
N. J.
,
2007
, “
Simulation and Model Validation of a Horizontal Shallow Basin Solar Concentrator
,”
Sol. Energy
,
81
(
4
), pp.
463
475
.
26.
ANSI/ASHRAE Standard
,
1977
, “
Methods of Testing to Determine the Thermal Performance of Solar Collectors
,”
American Society of Heating, Refrigeration and Air Conditioning Engineers, Inc.
,
New York
, Standard No. 93-2010, p. 42.
27.
Duffie
,
J. A.
, and
Beckman
,
W. A.
,
2013
,
Solar Engineering of Thermal Processes
,
Wiley
,
New York
.
28.
Imtiaz Hussain
,
M.
,
Ali
,
A.
, and
Lee
,
G. H.
,
2016
, “
Multi-Module Concentrated Photovoltaic Thermal System Feasibility for Greenhouse Heating: Model Validation and Techno-Economic Analysis
,”
Sol. Energy
,
135
, pp.
719
730
.
29.
Imtiaz Hussain
,
M.
, and
Lee
,
G. H.
,
2016
, “
Thermal Performance Comparison of Line-and Point-Focus Solar Concentrating Systems: Experimental and Numerical Analyses
,”
Sol. Energy
,
133
, pp.
44
54
.
30.
Howell
,
J. R.
,
1998
, “
A Catalog of Radiation Heat Transfer Configuration Factors
,”
University of Texas
, Austin, TX, accessed date Jan 2, 2016, http://www.thermalradiation.net/tablecon.html#C4
You do not currently have access to this content.