The CCD camera-based flux measurement at Paul Scherrer Institute's (PSI) high flux solar simulator (HFSS) is influenced by a spatially variable spectrum of the concentrated radiation characteristic for arc lamp-based solar simulators. This results in a substantial error in the radiative power determined by integration of the flux distribution. This systematic error is assessed by numerically modeling the response of the CCD camera in use. Measured spectra of concentrated radiation obtained at different points in the flux distribution, measured transmission characteristics of all optical elements, and published data for the spectral sensitivity of the CCD chip are applied in the model. The response of a water calorimeter is used as baseline case. It is shown that the magnitude of the error depends strongly on the region analyzed, i.e., on aperture size, on the wavelength band analyzed, and, unfortunately, also on the number of lamps in operation. A relative error in the range of 10–30% is observed if an aperture with 1 cm in diameter covering the region of peak concentration is considered. It will be shown that the error arises due to the fact that a photon counter (CCD camera) is used to determine the thermal power.
Skip Nav Destination
Article navigation
November 2012
Technical Briefs
Error Analysis of the Radiative Power Determined From Flux Distributions Measured With a Camera in a Xe Arc Lamp-Based Solar Simulator
Ivo Alxneit
Ivo Alxneit
Senior Scientist
Department General Energy,
Paul Scherrer Institute (PSI),
e-mail: ivo.alxneit@psi.ch
Solar Technology Laboratory
,Department General Energy,
Paul Scherrer Institute (PSI),
CH-5232, Villigen PSI
, Switzerland
e-mail: ivo.alxneit@psi.ch
Search for other works by this author on:
Ivo Alxneit
Senior Scientist
Department General Energy,
Paul Scherrer Institute (PSI),
e-mail: ivo.alxneit@psi.ch
Solar Technology Laboratory
,Department General Energy,
Paul Scherrer Institute (PSI),
CH-5232, Villigen PSI
, Switzerland
e-mail: ivo.alxneit@psi.ch
Contributed by the Solar Energy Division of ASME for publication in the JOURNAL OF SOLAR ENERGY ENGINEERING. Manuscript received November 30, 2011; final manuscript received May 16, 2012; published online October 4, 2012. Assoc. Editor: Wojciech Lipinski.
J. Sol. Energy Eng. Nov 2012, 134(4): 044501 (4 pages)
Published Online: October 4, 2012
Article history
Received:
November 30, 2011
Revision Received:
May 16, 2012
Citation
Alxneit, I. (October 4, 2012). "Error Analysis of the Radiative Power Determined From Flux Distributions Measured With a Camera in a Xe Arc Lamp-Based Solar Simulator." ASME. J. Sol. Energy Eng. November 2012; 134(4): 044501. https://doi.org/10.1115/1.4007493
Download citation file:
Get Email Alerts
Cited By
Related Articles
A Self-Calibration Method for Robotic Measurement System
J. Manuf. Sci. Eng (February,2000)
Detailed Performance Analysis of a 10 kW Dish∕Stirling System
J. Sol. Energy Eng (February,2008)
Measuring Tool-Chip Interface Temperatures
J. Eng. Ind (May,1986)
Experimental and Numerical Determination of Thermal Radiative Properties of ZnO Particulate Media
J. Heat Transfer (January,2010)
Related Proceedings Papers
Related Chapters
4-Bit Pipeline ADC for Monolithic Active Pixel Sensors
International Conference on Advanced Computer Theory and Engineering (ICACTE 2009)
Recognition of Emotions from Human Speech
Intelligent Engineering Systems through Artificial Neural Networks, Volume 20
Development of Nuclear Boiler and Pressure Vessels in Taiwan
Global Applications of the ASME Boiler & Pressure Vessel Code