An experimental study was conducted to investigate the effect of electronic flow control on the performance of a variable-speed heat pump. A heat pump with two different expansion devices (capillary tube and electronic expansion valve) was tested in a psychrometric calorimeter over a range of outdoor temperatures from −15 to 7°C. Heat pump performance was first optimized with respect to charge for each expansion device through cycle-matching tests. Parametric tests also were conducted by changing compressor speed and opening angle for the electronic expansion valve at each outdoor temperature. The refrigeration cycle characteristics of the electronic valve were illustrated using pressure-enthalpy diagrams. Performance enhancement was also analyzed in terms of superheat, heating capacity, and energy efficiency ratio (EER). Comparison of the capillary tube and electronic valve indicated that the superheat significantly improved when using the electronic valve. Also, unit showed larger heating capacity and EER with the electronic valve than with the capillary tube except when the compressor speed was above 95 Hz. Enhancement of heating performance became larger as outdoor temperature decreased.

1.
Stoecker
,
W. F.
,
Smith
,
D. L.
, and
Emde
,
B. N.
,
1981
, “
Influence of Expansion Device on the Seasonal Energy Requirements of a Residential Air Conditioner
,”
ASHRAE Trans.
,
87
, pp.
349
360
.
2.
Krakow
,
K. I.
,
Lin
,
S.
, and
Matsuki
,
K.
,
1987
, “
A Study of Primary Effects of Various Means of Refrigerant Flow Control and Capacity Control on the Seasonal Performance of a Heat Pump
,”
ASHRAE Trans.
,
93
, pp.
511
524
.
3.
Stoecker, W. F., and Jones, J. W., 1982, Refrigerant and Air Conditioning, McGraw–Hill, New York.
4.
Rice, C. K., and Fisher, S. K., 1985, “A Comparative Analysis of Single and Continuously Variable-Capacity Heat Pump Concepts,” CONF-841231.
5.
Kuehl
,
S. J.
, and
Goldschmidt
,
V. W.
,
1991
, “
Modeling of Steady Flow of R-22 Through Capillary Tubes: Test Data
,”
ASHRAE Trans.
,
97
, pp.
139
148
.
6.
Farzad
,
M.
, and
O’Neal
,
D. L.
,
1993
, “
Influence of the Expansion Device on Air-Conditioner System Performance Characteristics Under a Range of Charging Conditions
,”
ASHRAE Trans.
,
99
, pp.
3
13
.
7.
Choi
,
J. M.
,
Kim
,
Y. C.
,
Kim
,
J. Y.
, and
Bae
,
Y. D.
,
1997
, “
An Experimental Study on the Performance of an Inverter Heat Pump With Variation of Fre-quency and Capillary Size
,”
Korean J. Air Conditioning and Refrigeration Engineering
,
9
, pp.
64
72
.
8.
Park
,
Y. C.
,
Ha
,
D. Y.
, and
Min
,
M. K.
,
1998
, “
The Effect of Seasonal Performance of an Inverter Compressor With Higher and Lower Operating Ranges
,”
Korean J. of Air-Conditioning and Refrigeration Eng.
,
10
, pp.
173
179
.
9.
ASHRAE, 1983, Methods of testing for seasonal efficiency of unitary air-conditioners and heat pumps. ASHRAE Standard ANSI/ASHRAE 116–1983.
10.
Japanese Industrial Standard. Testing methods for unitary air conditioners, JIS B 8615-1884.
11.
ARI, 1989, Unitary air conditioning and air-source heat pump equipment, ARI Standard 210/240.
12.
ASHRAE, 1981, ASHRAE Handbook of Fundamentals, ASHRAE, New York.
13.
Robinson, J. H., 1996, “The Impact of Charge on Performance of an Air-to-Air Heat Pump for R22 and Three Binary Blends of Refrigerants 32 and 134a,” Master thesis, Texas A&M University.
14.
McQuiston, F. C., and Parker, J. D., 1988, Heating, Ventilating, and Air Conditioning: Analysis and Design, Wiley, New York.
15.
Incropera, F. P., and DeWitt, D. P., 2002, Fundamentals of Heat and Mass Transfer, John Wiley & Sons, New York.
You do not currently have access to this content.