A 35-kW rooftop photovoltaic (PV) system has been installed at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland. The system, located on the flat roof that connects NIST’s Administration Building to its adjoining conference and cafeteria facilities, produced NIST’s first site-generated renewable energy on September 14, 2001. In addition to providing electrical energy and reducing monthly peak electrical loads, the rear surface of each module is laminated to 51 mm of extruded polystyrene enhancing the thermal performance of the roof. A unique ballast system secures the photovoltaic system, eliminating the need for roof penetrations. An instrumentation and data acquisition package was installed to record the ambient temperature, wind speed, solar radiation, and the electrical energy delivered to the grid. Additional solar radiation instruments were installed after determining that the original solar radiation sensor was influenced by reflections from the south-facing wall of the Administration Building’s tower. NIST’s electric utility billing schedule includes energy and peak demand charges. The generation charges vary significantly depending upon the time interval—off-peak, intermediate, and on-peak—during which the energy is consumed. The schedule is divided into summer billing months (June–October) and winter billing months (November–May). During the winter billing months, the distribution, transmission, and generation peak demand charges are based on the greatest power demand imposed by the site on the grid. During the summer billing months, an additional demand charge is imposed to capture electrical demand during the on-peak time interval. This paper summarizes the monthly and annual measured performance of the photovoltaic system. The monthly energy produced by the system is tabulated. The system has provided 35676 kWh of electrical energy during its first year of operation. Conversion efficiencies—computed using solar radiation measurements from a single photovoltaic cell radiation sensor, four thermopile-based radiation sensors located around the perimeter of the photovoltaic array, and a remotely located thermopile-based radiation sensor—are presented. Annual conversion efficiencies of 10.8%, 8.8%, and 7.4% were achieved using cell, module, and foot print areas, respectively. Using the electric utility’s rate schedule, the monetary savings credited to the photovoltaic system is determined by combining the cost of the displaced energy with the reduction in peak demand charges attributable to the photovoltaic system. During its first year of operation, the system has saved $2678 with savings in demand charges, essentially equivalent to savings as a result of displaced energy. Finally, using utility provided data and the Environmental Protection Agency’s (EPA) Environmental Benefits Calculator, estimates are made of the avoided emissions of the photovoltaic system over its projected life span.
Skip Nav Destination
e-mail: hunter@nist.gov
e-mail: eweise@nist.gov
e-mail: khenders@nist.gov
Article navigation
August 2003
Technical Papers
Measured Impact of a Rooftop Photovoltaic System
A. Hunter Fanney,
e-mail: hunter@nist.gov
A. Hunter Fanney
National Institute of Standards and Technology, 100 Bureau Drive, MS 8632, Gaithersburg, MD 20899-8632
Search for other works by this author on:
Eric R. Weise,
e-mail: eweise@nist.gov
Eric R. Weise
National Institute of Standards and Technology, 100 Bureau Drive, MS 8632, Gaithersburg, MD 20899-8632
Search for other works by this author on:
Kenneth R. Henderson
e-mail: khenders@nist.gov
Kenneth R. Henderson
National Institute of Standards and Technology, 100 Bureau Drive, MS 8632, Gaithersburg, MD 20899-8632
Search for other works by this author on:
A. Hunter Fanney
National Institute of Standards and Technology, 100 Bureau Drive, MS 8632, Gaithersburg, MD 20899-8632
e-mail: hunter@nist.gov
Eric R. Weise
National Institute of Standards and Technology, 100 Bureau Drive, MS 8632, Gaithersburg, MD 20899-8632
e-mail: eweise@nist.gov
Kenneth R. Henderson
National Institute of Standards and Technology, 100 Bureau Drive, MS 8632, Gaithersburg, MD 20899-8632
e-mail: khenders@nist.gov
Contributed by the Solar Energy Division of THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS for publication in the ASME JOURNAL OF SOLAR ENERGY ENGINEERING. Manuscript received by the ASME Solar Energy Division, December 2002; final revision, March 2003. Associate Editor: A. Reddy.
J. Sol. Energy Eng. Aug 2003, 125(3): 245-250 (6 pages)
Published Online: August 4, 2003
Article history
Received:
December 1, 2002
Revised:
March 1, 2003
Online:
August 4, 2003
Citation
Fanney, A. H., Weise, E. R., and Henderson, K. R. (August 4, 2003). "Measured Impact of a Rooftop Photovoltaic System ." ASME. J. Sol. Energy Eng. August 2003; 125(3): 245–250. https://doi.org/10.1115/1.1591799
Download citation file:
Get Email Alerts
Cited By
Mass Flow Control Strategy for Maximum Energy Extraction in Thermal Energy Storage Tanks
J. Sol. Energy Eng (December 2025)
Exergy Optimization of a Hybrid Multi-Evaporative Desalination Plant Powered by Solar and Geothermal Energy
J. Sol. Energy Eng (June 2025)
Correlation for Maximum Heat Transfer Between Fluidized Bed and Its Wall and Application to Solar Power Plants
J. Sol. Energy Eng (June 2025)
Related Articles
Simulation and Model Validation of the Surface Cooling System for Improving the Power of a Photovoltaic Module
J. Sol. Energy Eng (November,2011)
A Study on Simulations of the Power Output and Practical Models for Building Integrated Photovoltaic Systems
J. Sol. Energy Eng (August,2004)
Experiences With Using Solar Photovoltaics to Heat Domestic Water
J. Sol. Energy Eng (May,2003)
High-Speed Monitoring of Multiple Grid-Connected Photovoltaic Array Configurations and Supplementary Weather Station
J. Sol. Energy Eng (June,2017)
Related Proceedings Papers
Related Chapters
Cooling of the Solar Cells for a Compound Parabolic Concentrating Photovoltaic Systems
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)
Final Report: Does the Underlayment Matter?
Roofing Research and Standards Development: 10th Volume
Genetic Approach for Predicting the Missing Value of the Pixel
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3