Abstract
In this work, we compare the pulse-shape discrimination (PSD) properties of newly developed liquid scintillator LSB-200, EJ-299-33A, BC-501A, stilbene, p-terphenyl, and Hidex Aqualight in neutron field generated by the LVR-15 reactor with silicon filter utilization. Pulses from the scintillators are processed by the Neutron-Gamma spectrometer. This spectrometric system with fast digitizer card contains two analog–digital converters with a resolution of 12 bits and sampling frequency 500 × 106 Hz. For photomultiplier linearity improvement, the active divider has been used. Measured data from scintillators have been processed using the integration method and compared. The results are presented.
Issue Section:
Technical Briefs
References
1.
Jančář
,
A.
,
Kopecký
,
Z.
,
Dressler
,
J.
,
Veškrna
,
M.
,
Matěj
,
Z.
,
Granja
,
C.
, and
Solar
,
M.
, 2015
, “
Pulse-Shape Discrimination of the New Plastic Scintillators in Neutron-Gamma Mixed Field Using Fast Digitizer Card
,” Radiat. Phys. Chem.
,
116
, pp. 60
–64
.10.1016/j.radphyschem.2015.05.0072.
Košťál
,
M.
,
Schulc
,
M.
,
Šoltés
,
J.
,
Losa
,
E.
,
Viererbl
,
L.
,
Matěj
,
Z.
,
Cvachovec
,
F.
, and
Rypar
,
V.
, 2018
, “
Measurements of Neutron Transport of Well Defined Silicon Filtered Beam in Lead
,” Appl. Radiat. Isotopes
,
142
, pp. 160
–166
.10.1016/j.apradiso.2018.08.0283.
Košťál
,
M.
,
Šoltés
,
J.
,
Viererbl
,
L.
,
Matěj
,
Z.
,
Cvachovec
,
F.
,
Rypar
,
V.
, and
Losa
,
E.
, 2017
, “
Measurement of Neutron Spectra in a Silicon Filtered Neutron Beam Using Stilbene Detectors at the LVR-15 Research Reactor
,” Appl. Radiat. Isotopes
,
128
, pp. 41
–48
.10.1016/j.apradiso.2017.06.0264.
VF Nuclear, “
Neutron Gamma Analyser
,” accessed Apr. 20, 2020, https://www.vfnuclear.com/en/neutron-gamma-analyser-nga-015.
HööK
,
M.
, 2006
, “
Study of the Pulse Shape as a Means to Identify Neutrons and Gammas in a NE213 Detector
,” Uppsala University, Neutron Physics Report.6.
Herman
,
O.
, 2016
, “
Fusion of Separation Methods
,” Master thesis,
Masaryk University
,
Brno, Czechia
.7.
Sardet
,
A.
,
Varignon
,
C.
,
Laurent
,
B.
,
Granier
,
T.
,
Oberstedt
,
A.
, and
Terphenyl
,
P.
, 2015
, “
An Alternative to Liquid Scintillators for Neutron Detection Nuclear Instruments and Methods in Physics Research
,” Phys. Res. Sect. A
,
792
, pp. 74
–80
.10.1016/j.nima.2015.04.0388.
Iwanowska
,
J.
,
Swiderski
,
L.
,
Moszynski
,
M.
,
Szczesniak
,
T.
,
Sibczynski
,
P.
,
Galunov
,
N. Z.
, and
Karavaeva
,
N. L.
, 2011
, “
Neutron/Gamma Discrimination Properties of Composite Scintillation Detectors
,” J. Instrum.
,
6
(07
), p. P07007
.10.1088/1748-0221/6/07/P07007Copyright © 2021 by ASME
You do not currently have access to this content.