This paper describes the design and use of a new irradiation facility for the LVR-15 nuclear research reactor. The CHOUCA MT irradiation rig was produced in France according to a design of the ÚJV Group (ÚJV Řež and Research Center Řež). There are six heating sections situated along the rig, each instrumented and controlled by its own thermocouple. The rig’s insulation layers ensure a balanced temperature in irradiated specimens along its entire length. The specimen holder is 55.9 mm in diameter and 320 mm long. The CHOUCA MT rig can be repetitively irradiated in different positions within the reactor core, depending on irradiation condition requirements. The CHOUCA MT rig expands the possibilities of radiation research in the ÚJV Group.
Issue Section:
Research Papers
References
1.
SOTEREM
, part of the NUEVESSEL Holding, 5 rue de la Technique, Castanet Tolosan Cedex, France
, www.soterem.fr/homepage_048.htm.2.
Marek
, M.
, Vins
, M.
, Lahodova
, Z.
, Viererbl
, L.
, and Koleska
, M.
, 2014
, “Extended Set of Activation Monitors for NCT Beam Characterization and Spectral Conditions of the Beam After Reactor Fuel Conversion
,” Appl. Radiat. Isot.
, 88
, pp. 157
–161
. 0969-804310.1016/j.apradiso.2013.11.0403.
Koleska
, M.
, Soltes
, J.
, Vins
, M.
, Viererbl
, L.
, Ernest
, J.
, and Lahodova
, Z.
, 2014
, “Commissioning of the New Irradiation Device for Neutron Transmutation Doping
,” IEEE Trans. Nucl. Sci.
, 61
(4
), pp. 2300
–2305
.10.1109/TNS.2014.23001004.
Rutte
, D.
, Pfander
, J. A.
, Koleska
, M.
, Jonckheere
, R.
, and Unterricker
, S.
, 2015
, “Radial Fast-Neutron Fluence Gradients During Rotating Ar-40/Ar-39 Sample Irradiation Recorded With Metallic Fluence Monitors and Geological Age Standards
,” Geochem. Geophys. Geosyst.
, 16
(1
), pp. 336
–345
.10.1002/2014GC0056115.
Koleska
, M.
, Viererbl
, L.
, Lahodova
, Z.
, Ernest
, J.
, Zmitkova
, J.
, and Marek
, M.
, 2014
, “Numerical and Experimental Determination of Neutron Characteristics in Irradiation Rigs Operated in LVR-15 Research Reactor
,” Radiat. Prot. Dosimetry
, 161
, pp. 316
–320
.10.1093/rpd/ncu1966.
Koleška
, M.
, Lahodova
, Z.
, Soltes
, J.
, Viererbl
, L.
, Ernest
, J.
, Vins
, M.
, and Stehno
, J.
, 2015
, “Capabilities of the LVR-15 Research Reactor for Production of Medical and Industrial Radioisotopes
,” J. Radioanal. Nucl. Chem.
, 305
(1
), pp. 51
–59
.10.1007/s10967-015-4025-5 0236-57317.
Vins
, M.
, Viererbl
, L.
, Lahodova
, Z.
, Marek
, M.
, Voljanskij
, A.
, Klupak
, V.
, and Koleska
, M.
, 2011
, “Comparison of the Neutron Energy Spectrum and Neutron Fluence Rate in the LVR-15 Research Reactor With Fuel With Different Enrichment
,” J. Radioanal. Nucl. Chem.
, 291
(2
), pp. 293
–298
. 0236-573110.1007/s10967-011-1277-68.
Oak Ridge National Laboratory, U.S.A.
, “Neutron Flux Spectra from Multiple Foil Activation Experiment
,” 1994
, NEA
, CCC-01112/04.9.
Pellowitz
, D. B.
, 2011
, MCNP User’s Manual
, Version 2.7.0 LANL, Los Alamos National Laboratory
.10.
Koleska
, M.
, Viererbl
, L.
, Lahodova
, Z.
, Ernest
, J.
, Zmitkova
, J.
, and Marek
, M.
, 2014
, “Numerical and experimental determination of neutron characteristics in radiation rigs operated in 15 research reactor
,” Radiat Prot Dosimetry, pp. 1
–5
.10.1093/rpd/ncu19611.
12.
GAMBIT 2.3 Modeling Guide
, 2006
, Vols. 1, 2
, Fluent Inc
, Central Resource Park, Lebanon, NH
, www.fluent.com.13.
Norgett
, M. J.
, Robinson
, M. T.
, and Torrens
, I. M.
, 1975
, “A Proposed Method of Calculating Displacement Dose Rates
,” Nucl. Eng. Des.
, 33
, pp. 50
–54
. 0029-549310.1016/0029-5493(75)90035-7Copyright © 2017 by ASME
You do not currently have access to this content.