Article Type: Technical Briefs
J. Med. Devices. March 2019, 13(1): 014505.
Paper No: MED-18-1190
Published Online: December 6, 2018
... and Rehabilitation Device for the Home ,” IEEE/RSJ International Conference on Intelligent Robots and Systems , San Diego, CA , Oct. 29–Nov. 2 , pp. 3348 – 3353 . 10.1109/IROS.2007.4398980 [6] Mukai , T. , Hirano , S. , Nakashima , H. , Sakaida , Y. , and Guo , S. , 2011...
Journal Articles
Article Type: Research-Article
J. Med. Devices. September 2018, 12(3): 031009.
Paper No: MED-17-1278
Published Online: July 30, 2018
.... Manuscript received August 4, 2017; final manuscript received June 26, 2018; published online July 30, 2018. Assoc. Editor: Elizabeth Hsiao-Wecksler. 04 08 2017 26 06 2018 Medical robotics Neurological devices Rehabilitation devices Sensors and actuators The international...
Journal Articles
Article Type: Research-Article
J. Med. Devices. September 2018, 12(3): 031007.
Paper No: MED-17-1283
Published Online: July 24, 2018
.... Patterson. 10 08 2017 27 05 2018 Medical devices Medical devices Medical instrumentation Minimally invasive devices Rehabilitation devices Tissue engineered devices Design processes Equipment Every year around 16 × 10 9 of injections are administrated worldwide...
Journal Articles
Article Type: Expert View
J. Med. Devices. September 2018, 12(3): 034701.
Paper No: MED-18-1024
Published Online: July 13, 2018
.... Manuscript received February 6, 2018; final manuscript received May 23, 2018; published online July 13, 2018. Assoc. Editor: Michael Eggen. 06 02 2018 23 05 2018 Cardiovascular devices Medical devices Medical devices Neurological devices Orthopedic devices Rehabilitation devices...
Journal Articles
Article Type: Research-Article
J. Med. Devices. September 2018, 12(3): 031001.
Paper No: MED-17-1011
Published Online: July 13, 2018
... Rehabilitation devices Many individuals with lower limb amputation have difficulty maintaining balance while walking, especially in real-world situations that require quick responses to changes in terrain. One quarter of outdoor falls, where a wide variety of uneven terrains exists, occur in the coronal...
Journal Articles
Article Type: Research-Article
J. Med. Devices. March 2018, 12(1): 011010.
Paper No: MED-17-1312
Published Online: January 30, 2018
...Evandro Ficanha; Guilherme Ribeiro; Lauren Knop; Mo Rastgaar An understanding of the time-varying mechanical impedance of the ankle during walking is fundamental in the design of active ankle-foot prostheses and lower extremity rehabilitation devices. This paper describes the estimation of the time...
Journal Articles
Article Type: Design Innovation Paper
J. Med. Devices. December 2017, 11(4): 045002.
Paper No: MED-16-1356
Published Online: October 4, 2017
...; published online October 4, 2017. Assoc. Editor: Michael Eggen. 07 11 2016 07 08 2017 Human performance Force assessment Medical devices Medical robotics Rehabilitation devices Equipment Movement disorders impair a person's ability to produce and control bodily movements...
Journal Articles
Article Type: Research-Article
J. Med. Devices. September 2017, 11(3): 031012.
Paper No: MED-16-1355
Published Online: July 18, 2017
... received November 6, 2016; final manuscript received April 28, 2017; published online July 18, 2017. Assoc. Editor: Rita M. Patterson. 06 11 2016 28 04 2017 Medical instrumentation Rehabilitation devices Sensors and actuators Sports Instrumentation and Devices...
Journal Articles
Article Type: Research-Article
J. Med. Devices. September 2017, 11(3): 031010.
Paper No: MED-16-1345
Published Online: June 27, 2017
... environment. 1 Corresponding author. Manuscript received October 22, 2016; final manuscript received April 7, 2017; published online June 27, 2017. Assoc. Editor: Matthew R. Myers. 22 10 2016 07 04 2017 Bio-Heat transfer devices Medical devices Rehabilitation devices...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. March 2017, 11(1): 014503.
Paper No: MED-16-1216
Published Online: December 21, 2016
... the past years. However, many robot-assisted rehabilitation devices have limitations; one of which is being bulky and complex to handle. Large and expensive devices that require special training to operate are less attractive to clinics and therapists, and ultimately less likely to be available to patients...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. December 2016, 10(4): 044509.
Paper No: MED-16-1201
Published Online: September 12, 2016
...: Venketesh Dubey. 29 03 2016 06 07 2016 Human factors Human performance and force assessment Medical devices Medical robotics Orthopedic devices Rehabilitation devices Design processes Duchenne muscular dystrophy (DMD) is the most common form of muscular dystrophy...
Journal Articles
Article Type: Research-Article
J. Med. Devices. December 2016, 10(4): 041005.
Paper No: MED-15-1207
Published Online: August 24, 2016
.... , and Kerrigan , D. C. , 2007 , “ A Kinematic and Kinetic Comparison of Overground and Treadmill Walking in Healthy Subjects ,” Gait Posture , 26 ( 1 ), pp. 17 – 24 . 10.1016/j.gaitpost.2006.07.003 Medical devices Rehabilitation devices Sensors and actuators Sports Instrumentation and Devices...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. December 2016, 10(4): 044504.
Paper No: MED-15-1253
Published Online: August 11, 2016
... 22 02 2016 Medical robotics Rehabilitation devices Sensors and actuators In this work, the glove was controlled by pressure. The desired air pressure ( P ref ) has to be obtained empirically from different participants. It would be ideal to be able to conduct closed-loop position...
Journal Articles
Article Type: Design Innovation Paper
J. Med. Devices. December 2016, 10(4): 045001.
Paper No: MED-15-1258
Published Online: August 11, 2016
... received September 10, 2015; final manuscript received February 25, 2016; published online August 11, 2016. Assoc. Editor: Rita M. Patterson. 10 09 2015 25 02 2016 Medical devices Rehabilitation devices Sensors and actuators Equipment KAFOs are long leg orthoses that span...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. December 2016, 10(4): 044503.
Paper No: MED-15-1271
Published Online: August 5, 2016
...% suffer from cognitive deficits [ 1 , 2 ]. Medical robotics Rehabilitation devices Sensors and actuators Copyright © 2016 by ASME 2016 1932-6181/2016/10(4)/044503/4/ $25.00 ...
Journal Articles
Article Type: Research-Article
J. Med. Devices. December 2016, 10(4): 041002.
Paper No: MED-15-1208
Published Online: August 5, 2016
... devices Rehabilitation devices Sensors and actuators Equipment While the purpose of this study was to create and understand a technology platform that takes advantage of the force and power density of hydraulics, it is useful to speculate on how well that technology might match particular...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. December 2016, 10(4): 044501.
Paper No: MED-15-1252
Published Online: August 5, 2016
... show snapshots of the walking linkage over the completed trajectory and the foot bracket, respectively. This foot bracket also has slotted holes for straps to fix the foot. 04 09 2015 09 03 2016 Medical devices Medical robotics Rehabilitation devices Equipment Robotic...
Journal Articles
Article Type: Technical Briefs
J. Med. Devices. March 2016, 10(1): 014503.
Paper No: MED-15-1225
Published Online: February 15, 2016
... 12 2015 Medical devices Rehabilitation devices Equipment DVT and pulmonary embolism are medical conditions that are often grouped together and referred to as “venous thromboembolism.” In the U.S., it is estimated that 350,000 individuals are affected each year by these conditions...
Journal Articles
Article Type: Design Innovation Paper
J. Med. Devices. September 2015, 9(3): 035001.
Paper No: MED-14-1199
Published Online: September 1, 2015
... as much natural motion as possible for amputees. Rehabilitation devices A lower limb prosthesis is able to restore mobility to patients who have lost a limb; however, no current replacement is as moveable and adaptable as the limb that was lost. Therefore, all amputees suffer from...
Journal Articles
Article Type: Design Innovation Paper
J. Med. Devices. December 2015, 9(4): 045002.
Paper No: MED-15-1023
Published Online: August 12, 2015