Transcranial Direct Current Stimulation (tDCS) is a non-invasive procedure where a weak electrical current (260 to 2 mA) is applied across the scalp to modulate brain function. tDCS has been applied for therapeutic purposes (e.g. addiction, depression, mood and sleep disorders) as well as cognitive performance enhancement (e.g. memory consolidation, motor learning and language recall). Despite safety and cost advantages, the developments of tDCS therapies have been restricted by spatial targeting concerns using existing two-channel systems. We have developed novel technology for High-Density tDCS (HD-tDCS) that improves spatial focality. Integral to the system are specialized HD-tDCS electrodes ( mm diameter) which allow safe and comfortable passage of current across the scalp. Here we evaluate a range of HD-tDCS electrode designs for comfort as well as test electrode over-potential, pH, and temperature. Passing 2 mA current for 22 minutes, both anodal and cathodal stimulations were evaluated independently. Subjective sensation during forearm stimulation was evaluated in 8 subjects. The benefits of skin electrical or chemical pre-conditioning were tested. Conductive Rubber, Ag, AgCl, pellet electrodes and AgCl ring electrodes were evaluated in combination with salty gels (Signa and CCNY4) and nominally electrolyte free gel (Lectron). The use of AgCl ring electrodes in combination with CCNY4 gel resulted in no significant pH, temperature, or over-potential changes under either polarity stimulation and was well tolerated by subjects. HD-tDCS may thus be applied with 2 mA per electrode for up to 22 minutes without skin irritation. Moreover, skin pre-conditioning can eliminate sensation such that HD-tDCS can be applied in a blinded fashion and under a broad range of therapeutic and performance enhancement applications. Our HD-tDCS system allows non-invasive, safe, and targeted modulation of selected cortical structures for electrotherapies that are individualized as well as optimized for a range of therapeutic applications.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
High-Density Transcranial Direct Current Stimulation (HD-tDCS): Skin Safety and Comfort
M. Bikson
M. Bikson
The City College of New York
, USA
Search for other works by this author on:
J. Patel
The City College of New York
, USA
V. Bansal
The City College of New York
, USA
P. Minha
The City College of New York
, USA
J. Ho
The City College of New York
, USA
A. Datta
The City College of New York
, USA
M. Bikson
The City College of New York
, USAJ. Med. Devices. Jun 2009, 3(2): 027554 (1 pages)
Published Online: July 24, 2009
Article history
Published:
July 24, 2009
Citation
Patel, J., Bansal, V., Minha, P., Ho, J., Datta, A., and Bikson, M. (July 24, 2009). "High-Density Transcranial Direct Current Stimulation (HD-tDCS): Skin Safety and Comfort." ASME. J. Med. Devices. June 2009; 3(2): 027554. https://doi.org/10.1115/1.3155369
Download citation file:
Get Email Alerts
Cited By
A Better Way to Visualize the Cervix: A Low-Cost Cervical Cancer Screening Device for LMIC Settings
J. Med. Devices (April 2025)
Comparative Survey-Based Study of Noninvasive Saliva Collection Devices
J. Med. Devices (April 2025)
Related Articles
High-Density Transcranial Direct Current Stimulation (HD-tDCS): Skin Safety and Comfort
J. Med. Devices (June,2009)
High-Density Transcranial Direct Current Stimulation (HD-tDCS): Hardware Interface
J. Med. Devices (June,2009)
High-Density Transcranial DC Stimulation (HD-tDCS): Targeting Software
J. Med. Devices (June,2009)
Improving the Performance of Implantable Electrostimulation Devices Using Electrically Conducting Polymers
J. Med. Devices (June,2011)
Related Proceedings Papers
Related Chapters
Experimental Research on Flexural Tensile Properties of Layer Steel Fiber Reinforced Rubber Concrete
Proceedings of the 2010 International Conference on Mechanical, Industrial, and Manufacturing Technologies (MIMT 2010)
Performance Analysis of Rear Rubber Bushing Stiffness of Lower Control Arm on McPherson Suspension
Proceedings of the 2010 International Conference on Mechanical, Industrial, and Manufacturing Technologies (MIMT 2010)
A Study on Long-Term Seal Durability and Fracture Mode of Rubber O-Ring by High-Pressure Hydrogen Gas Cycles
International Hydrogen Conference (IHC 2012): Hydrogen-Materials Interactions