Micropump, an actuation source to transfer the fluid from reservoir to the target place with accuracy and reliability, plays an important role in microfluidic devices. A broad range of micropump applications in biomedical fields are found in the fluid fine regulation and precise control systems for implantable drug delivery, chemical and biological detection, as well as blood transport in cardiology system. A polydimethylsiloxane (PDMS) magnetic composite membrane based on microfabrication with dimensions of 6 mm and 65 in diameter and thickness respectively, is employed to actuate a proposed micropump. In micro pumping operation, the fluid flow effects on the actuation and dynamic response of an oscillating membrane are curial to the design of the micropump. Therefore, the resonant frequency of this micro device is estimated considering the added mass and fluid damping to understand the behaviors of the valveless micropump. In this study, the membrane actuation is implemented by a miniaturized electromagnet, which provides an external time-varying magnetic field. The magnetic force on the membrane is proportional to the gradient of the magnetic field and the magnetization of the micro particles embedded in the membrane. The alternating attractive and repulsive magnetic forces on this composite membrane are computed by Finite Element Analysis (FEA). The basic design issues of the electromagnetic actuator involving air gaps, input current signals, and distribution of magnetic flux in the magnetic circuit are presented. Moreover, the magnetic-structure coupling analysis is conducted to determine the maximum deformation and stresses on the membrane, which result from the action of these magnetic forces. Finally, frequency-dependent flow rate of a dual-chamber configuration micropump has been studied. The pumping rate increases almost linearly with the excitation frequency at low ranges and there exists resonant frequencies at which the flow rate will reach a maximum value. After the flow rate peaks, the pumping rate decreases sharply along with the actuating frequencies. The maximum flow rate for the dual-chamber remains at under 0.4 A input current with an excitation frequency of 3 Hz. For comparison, a single-chamber micropump reaches a maximum flow rate of with a resonant frequency of 4.36 Hz under the same condition.
Design Of Medical Devices Conference Abstracts
Design and Characterization of a Magnetically Driven Valveless Micropump for Drug Delivery
Y. Zhou,
Y. Zhou
Biomechanics Research Laboratory, Department of Mechanical and Industrial Engineering,
University of Illinois
, Chicago, IL 60607, USA
Search for other works by this author on:
F. Amirouche,
F. Amirouche
Biomechanics Research Laboratory, Department of Mechanical and Industrial Engineering,
University of Illinois
, Chicago, IL 60607, USA
Search for other works by this author on:
L. Chen
L. Chen
Biomechanics Research Laboratory, Department of Mechanical and Industrial Engineering,
University of Illinois
, Chicago, IL 60607, USA
Search for other works by this author on:
Y. Zhou
Biomechanics Research Laboratory, Department of Mechanical and Industrial Engineering,
University of Illinois
, Chicago, IL 60607, USA
F. Amirouche
Biomechanics Research Laboratory, Department of Mechanical and Industrial Engineering,
University of Illinois
, Chicago, IL 60607, USA
L. Chen
Biomechanics Research Laboratory, Department of Mechanical and Industrial Engineering,
University of Illinois
, Chicago, IL 60607, USAJ. Med. Devices. Jun 2009, 3(2): 027553 (1 pages)
Published Online: July 24, 2009
Article history
Published:
July 24, 2009
Citation
Zhou, Y., Amirouche, F., and Chen, L. (July 24, 2009). "Design and Characterization of a Magnetically Driven Valveless Micropump for Drug Delivery." ASME. J. Med. Devices. June 2009; 3(2): 027553. https://doi.org/10.1115/1.3147558
Download citation file: