This study evaluated the biomechanical efficacy of single-tunnel double-bundle anterior cruciate ligament (ACL) reconstruction technique. The graft construct is achieved using a novel fixation device that splits an ACL (SPACL) graft into two bundles, recreating the anteromedial (AM) and posterolateral (PL) bundles for ACL reconstruction. A pullout strength test of the SPACL was performed using a 7-mm bovine digital extensor tendon graft. The capability in restoration of knee kinematics after SPACL reconstruction was investigated using cadaveric human knees on a robotic testing system under an anterior tibial load of 134 N and a simulated quadriceps load of 400 N. The data indicated that the SPACL graft has a pullout strength of 823.7±172.3 N. Under the 134 N anterior tibial load, the anteroposterior joint laxity had increased constraint using the SPACL reconstruction but not significantly (p > 0.05) at all selected flexion angles. Under the 400 N quadriceps load, no significant differences were observed between the anterior tibial translation of intact knee and SPACL conditions at all selected flexion angles, but the SPACL graft induced a significant increase in external tibial rotation compared to the intact knee condition at all selected flexion angles with a maximal external rotation of −3.20 deg ±3.6 deg at 90 deg flexion. These data showed that the SPACL technique is equivalent or superior to existing ACL reconstruction techniques in restoration of knee laxity and kinematics. The new SPACL reconstruction technique could provide a valuable alternation to contemporary ACL reconstruction surgery by more closely recreating native ACL kinematics.
Skip Nav Destination
Article navigation
March 2018
Research-Article
A Novel Graft Fixation Technique for Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon Grafts
Guoan Li,
Guoan Li
Orthopaedic Biomechanics Lab,
Department of Orthopaedic Surgery,
Newton-Wellesley Hospital/Harvard
Medical School,
Newton, MA 02462
e-mail: Gli1@partners.org
Department of Orthopaedic Surgery,
Newton-Wellesley Hospital/Harvard
Medical School,
Newton, MA 02462
e-mail: Gli1@partners.org
Search for other works by this author on:
Ali Hosseini,
Ali Hosseini
Orthopaedic Biomechanics Lab,
Department of Orthopaedic Surgery,
Newton-Wellesley Hospital/Harvard
Medical School,
Newton, MA 02462
Department of Orthopaedic Surgery,
Newton-Wellesley Hospital/Harvard
Medical School,
Newton, MA 02462
Search for other works by this author on:
Hemanth Gadikota,
Hemanth Gadikota
Orthopaedic Biomechanics Lab,
Department of Orthopaedic Surgery,
Newton-Wellesley Hospital/Harvard
Medical School,
Newton, MA 02462
Department of Orthopaedic Surgery,
Newton-Wellesley Hospital/Harvard
Medical School,
Newton, MA 02462
Search for other works by this author on:
Thomas Gill
Thomas Gill
Orthopaedic Biomechanics Lab,
Department of Orthopaedic Surgery,
Newton-Wellesley Hospital/Harvard
Medical School,
Newton, MA 02462
Department of Orthopaedic Surgery,
Newton-Wellesley Hospital/Harvard
Medical School,
Newton, MA 02462
Search for other works by this author on:
Guoan Li
Orthopaedic Biomechanics Lab,
Department of Orthopaedic Surgery,
Newton-Wellesley Hospital/Harvard
Medical School,
Newton, MA 02462
e-mail: Gli1@partners.org
Department of Orthopaedic Surgery,
Newton-Wellesley Hospital/Harvard
Medical School,
Newton, MA 02462
e-mail: Gli1@partners.org
Ali Hosseini
Orthopaedic Biomechanics Lab,
Department of Orthopaedic Surgery,
Newton-Wellesley Hospital/Harvard
Medical School,
Newton, MA 02462
Department of Orthopaedic Surgery,
Newton-Wellesley Hospital/Harvard
Medical School,
Newton, MA 02462
Hemanth Gadikota
Orthopaedic Biomechanics Lab,
Department of Orthopaedic Surgery,
Newton-Wellesley Hospital/Harvard
Medical School,
Newton, MA 02462
Department of Orthopaedic Surgery,
Newton-Wellesley Hospital/Harvard
Medical School,
Newton, MA 02462
Thomas Gill
Orthopaedic Biomechanics Lab,
Department of Orthopaedic Surgery,
Newton-Wellesley Hospital/Harvard
Medical School,
Newton, MA 02462
Department of Orthopaedic Surgery,
Newton-Wellesley Hospital/Harvard
Medical School,
Newton, MA 02462
1Corresponding author.
Manuscript received April 26, 2017; final manuscript received October 9, 2017; published online November 22, 2017. Assoc. Editor: Rita M. Patterson.
J. Med. Devices. Mar 2018, 12(1): 011004 (6 pages)
Published Online: November 22, 2017
Article history
Received:
April 26, 2017
Revised:
October 9, 2017
Citation
Li, G., Hosseini, A., Gadikota, H., and Gill, T. (November 22, 2017). "A Novel Graft Fixation Technique for Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon Grafts." ASME. J. Med. Devices. March 2018; 12(1): 011004. https://doi.org/10.1115/1.4038307
Download citation file:
687
Views
Get Email Alerts
Cited By
A Portable Aspiration-Assisted Device for End-Cut Prostate Biopsy of Large Tissue Sample
J. Med. Devices (June 2025)
Paper errata statement
J. Med. Devices
Related Articles
Patient-Specific Guides for Total Hip Arthroplasty: A Paired Acetabular and Femoral Implantation Approach
J. Med. Devices (March,2015)
Roentgen Stereophotogrammetric Analysis Methods for Determining Ten Causes of Lengthening of a Soft-Tissue Anterior Cruciate Ligament Graft Construct
J Biomech Eng (August,2008)
Finite Element Model of the Knee for Investigation of Injury Mechanisms: Development and Validation
J Biomech Eng (January,2014)
Introduction
J. Med. Devices (September,2016)
Related Proceedings Papers
Related Chapters
Cruciate Ligament Injuries in Female Alpine Ski Racers
Skiing Trauma and Safety: Seventh International Symposium
The Effect of Anterior Cruciate Ligament Injury on Tibiofemoral Joint Biomechanics: Under Draw Load
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)
Analysis of Carving and Conventional Ski Measured Pressured Distributions During Carving Turns
Skiing Trauma and Safety: Fourteenth Volume