Prior studies have linked microbial contamination of intravenous (IV) ports and stopcocks with postoperative infections. Existing technologies to address contamination are not consistently utilized because of the time and effort they require. Herein, novel barrier devices were created that form a protective shell to passively prevent contact between injection sites and practitioner hands or environmental surfaces while still allowing rapid connection of a syringe for injection of medications via an opening in the shell. Prototypes were tested using a grossly contaminated environment and adenosine triphosphate (ATP)-bioluminescence assay. For eight pairs of unshielded versus shielded IV ports/stopcocks, average contamination was 4102 versus 35 RLU (p < 0.02), respectively, indicating that the devices could significantly reduce IV port/stopcock contamination.
Skip Nav Destination
Article navigation
September 2017
Technical Briefs
Design and Preliminary Testing of Novel Injection Port Contamination Barrier Devices
David B. Wax,
David B. Wax
Department of Anesthesiology,
Mount Sinai School of Medicine,
1 Gustave L. Levy Place,
New York, NY 10029
e-mail: david.wax@mssm.edu
Mount Sinai School of Medicine,
1 Gustave L. Levy Place,
New York, NY 10029
e-mail: david.wax@mssm.edu
Search for other works by this author on:
Bryan Hill
Bryan Hill
Department of Anesthesiology,
Mount Sinai School of Medicine,
New York, NY 10029
Mount Sinai School of Medicine,
New York, NY 10029
Search for other works by this author on:
David B. Wax
Department of Anesthesiology,
Mount Sinai School of Medicine,
1 Gustave L. Levy Place,
New York, NY 10029
e-mail: david.wax@mssm.edu
Mount Sinai School of Medicine,
1 Gustave L. Levy Place,
New York, NY 10029
e-mail: david.wax@mssm.edu
Bryan Hill
Department of Anesthesiology,
Mount Sinai School of Medicine,
New York, NY 10029
Mount Sinai School of Medicine,
New York, NY 10029
1Corresponding author.
Manuscript received August 11, 2016; final manuscript received December 26, 2016; published online June 27, 2017. Editor: William Durfee.
J. Med. Devices. Sep 2017, 11(3): 034503 (2 pages)
Published Online: June 27, 2017
Article history
Received:
August 11, 2016
Revised:
December 26, 2016
Citation
Wax, D. B., and Hill, B. (June 27, 2017). "Design and Preliminary Testing of Novel Injection Port Contamination Barrier Devices." ASME. J. Med. Devices. September 2017; 11(3): 034503. https://doi.org/10.1115/1.4036026
Download citation file:
Get Email Alerts
Cited By
Related Articles
Automated Real-Time Processing of Single Lead Electrocardiogram for Simultaneous Heart Rate and Respiratory Rate Monitoring
J. Med. Devices (June,2017)
The Role of Computational Modeling and Simulation in the Total Product Life Cycle of Peripheral Vascular Devices
J. Med. Devices (June,2017)
Magnetic Chest Tube Positioning System
J. Med. Devices (June,2018)
Data Communication Pathway for Sensing Guidewire at Proximal Side: A Review
J. Med. Devices (June,2017)
Related Proceedings Papers
Related Chapters
Artificial Indents as the Root Cause of Rolling Contact Fatigue Damage: Effect of Plastic Properties
Bearing and Transmission Steels Technology
Subsection NF—Supports
Companion Guide to the ASME Boiler & Pressure Vessel Codes, Volume 1 Sixth Edition
Section VIII: Division 2—Alternative Rules
Companion Guide to the ASME Boiler & Pressure Vessel Code, Volume 2, Second Edition: Criteria and Commentary on Select Aspects of the Boiler & Pressure Vessel and Piping Codes