Continuous flow offers notable advantages over batch processing for analytical applications like gene expression profiling of biological material, which demands very high processing. The technology of choice for future genetic analyzers will most likely use the polymerase chain reaction (PCR); therefore, high-throughput, high-speed PCR devices have raised enormous interest. Continuous-flow, biphasic PCR can meet these requirements but segmenting∕carrier fluids chemically compatible with the PCR are needed. The present paper compares several fluids in terms of compatibility with PCR and fluidic dynamics in a continuous, two-phase flow microfluidic device, and PCR efficiency was assessed quantitatively. The results represent the first step toward rational fluid design for biphasic continuous PCR.
Skip Nav Destination
e-mail: edmond.walsh@ul.ie
Article navigation
December 2007
Research Papers
Compatibility of Segmenting Fluids in Continuous-Flow Microfluidic PCR
E. J. Walsh,
E. J. Walsh
Stokes Research Institute,
e-mail: edmond.walsh@ul.ie
University of Limerick
, Castletroy, Limerick, Ireland
Search for other works by this author on:
C. King,
C. King
Stokes Research Institute,
University of Limerick
, Castletroy, Limerick, Ireland
Search for other works by this author on:
R. Grimes,
R. Grimes
Stokes Research Institute,
University of Limerick
, Castletroy, Limerick, Ireland
Search for other works by this author on:
A. Gonzalez,
A. Gonzalez
Stokes Research Institute,
University of Limerick
, Castletroy, Limerick, Ireland
Search for other works by this author on:
D. Ciobanu
D. Ciobanu
Stokes Research Institute,
University of Limerick
, Castletroy, Limerick, Ireland
Search for other works by this author on:
E. J. Walsh
Stokes Research Institute,
University of Limerick
, Castletroy, Limerick, Irelande-mail: edmond.walsh@ul.ie
C. King
Stokes Research Institute,
University of Limerick
, Castletroy, Limerick, Ireland
R. Grimes
Stokes Research Institute,
University of Limerick
, Castletroy, Limerick, Ireland
A. Gonzalez
Stokes Research Institute,
University of Limerick
, Castletroy, Limerick, Ireland
D. Ciobanu
Stokes Research Institute,
University of Limerick
, Castletroy, Limerick, IrelandJ. Med. Devices. Dec 2007, 1(4): 241-245 (5 pages)
Published Online: September 12, 2007
Article history
Received:
February 20, 2007
Revised:
September 12, 2007
Citation
Walsh, E. J., King, C., Grimes, R., Gonzalez, A., and Ciobanu, D. (September 12, 2007). "Compatibility of Segmenting Fluids in Continuous-Flow Microfluidic PCR." ASME. J. Med. Devices. December 2007; 1(4): 241–245. https://doi.org/10.1115/1.2812426
Download citation file:
Get Email Alerts
Cited By
Related Articles
Discussion “Pressure Drop During Refrigerant Condensation Inside Horizontal Smooth, Helical Microfin, and Herringbone Microfin Tubes” ( Olivier, J. A., Liebenberg, L., Kedzierski, M. A., and Meyer, J. P., 2004, J. Heat Transfer, 126(5), pp. 687–696 )
J. Heat Transfer (January,2008)
Comparison of Geometries for Diffusion-Based Extraction of Dimethyl Sulphoxide From a Cell Suspension
J. Med. Devices (June,2008)
Jet Flows Around Microbubbles in Subcooled Boiling
J. Heat Transfer (August,2005)
Heat Transfer Photogallery
J. Heat Transfer (August,2005)
Related Proceedings Papers
Related Chapters
Thermal Design Guide of Liquid Cooled Systems
Thermal Design of Liquid Cooled Microelectronic Equipment
Applications
Introduction to Finite Element, Boundary Element, and Meshless Methods: With Applications to Heat Transfer and Fluid Flow
LC-MS/MS on Microfluidic Device for Chloramphenicol Determination in Milk and Honey Samples Based on Molecular Imprinted Polymers
International Conference on Computer and Electrical Engineering 4th (ICCEE 2011)