This work presents a novel miniature contact-aided compliant joint mechanism that can be integrated into millimeter-sized manual or robotic surgical instruments. The design aims to address the trade-off between notched-tube compliant joints' range of motion and stiffness, while also ensuring a compact form factor. The mechanism is constructed from a nitinol tube with asymmetric cutouts and is actuated in bending by a cable. The innovative feature of this design is the incorporation of a contact aid into the notched-tube topology, which acts to both increase the stiffness of the joint and change the shape that it undertakes during bending. Using finite element modeling (FEM) techniques, we present a sensitivity analysis investigating how the performance of this contact-aided compliant mechanism (CCM) is affected by its geometry, and derive a kinematics and statics model for the joint. The FEM simulations and the kinematic and static models are compared to experimental results. The design and modeling presented in this study can be used to develop new miniature dexterous instruments, with a particular emphasis on applications in minimally invasive neurosurgery.

References

1.
York
,
P. A.
,
Swaney
,
P. J.
,
Gilbert
,
H. B.
, and
Webster
,
R. J.
, III
,
2015
, “
A Wrist for Needle-Sized Surgical Robots
,”
IEEE International Conference on Robotics and Automation
(
ICRA
), Seattle, WA, May 26–30, pp.
1776
1781
.
2.
Swaney
,
P. J.
,
York
,
P. A.
,
Gilbert
,
H. B.
,
Burgner-Kahrs
,
J.
, and
Webster
,
R. J.
, III
,
2016
, “
Design, Fabrication, and Testing of a Needle-Sized Wrist for Surgical Instruments
,”
ASME J. Med. Devices
,
11
(
1
), p.
014501
.
3.
Eastwood
,
K. W.
,
Azimian
,
H.
,
Carrillo
,
B.
,
Looi
,
T.
,
Naguib
,
H. E.
, and
Drake
,
J. M.
,
2016
, “
Kinetostatic Design of Asymmetric Notch Joints for Surgical Tools
,”
IEEE/RSJ International Conference on Intelligent Robots and Systems
(
IROS
), Daejeon, South Korea, Oct. 9–14, pp.
667
672
.
4.
Kato
,
T.
,
Okumura
,
I.
,
Kose
,
H.
,
Takagi
,
K.
, and
Hata
,
N.
,
2014
, “
Extended Kinematic Mapping of Tendon-Driven Continuum Robot for Neuroendoscopy
,”
IEEE/RSJ International Conference on Intelligent Robots and Systems
(
IROS
), Chicago, IL, Sept. 14–18, pp.
1997
2002
.
5.
Dewaele
,
F.
,
Kalmar
,
A. F.
,
De Ryck
,
F.
,
Lumen
,
N.
,
Williams
,
L.
,
Baert
,
E.
,
Vereecke
,
H.
,
Okito
,
J. P. K.
,
Mabilde
,
C.
,
Blanckaert
,
B.
,
Keereman
,
V.
,
Leybaert
,
L.
,
Van Nieuwenhove
,
Y.
,
Caemaert
,
J.
, and
Van Roost
,
D.
,
2014
, “
A Novel Design for Steerable Instruments Based on Laser-Cut Nitinol
,”
J. Surg. Innovation
,
21
(
3
), pp.
303
311
.
6.
Kanada
,
Y.
,
Yoneyama
,
T.
,
Watanabe
,
T.
,
Kagawa
,
H.
,
Sugiyama
,
N.
,
Tanaka
,
K.
, and
Hanyu
,
T.
,
2013
, “
Force Feedback Manipulating System for Neurosurgery
,”
Proc. First CIRP Conf. Biomanuf.
,
5
(
1
), pp.
133
136
.
7.
Yoneyama
,
T.
,
Watanabe
,
T.
,
Kagawa
,
H.
,
Hamada
,
J.
,
Hayashi
,
Y.
, and
Nakada
,
M.
,
2011
, “
Force Detecting Gripper and Flexible Micro Manipulator for Neurosurgery
,”
Annual International Conference of the IEEE Engineering in Medicine and Biology Society
(
IEMBS
), Boston, MA, Aug. 3–Sept. 3, pp.
6695
6699
.
8.
Bell
,
J. A.
,
Saikus
,
C. E.
,
Ratnayaka
,
K.
,
Wu
,
V.
,
Sonmez
,
M.
,
Faranesh
,
A. Z.
,
Colyer
,
J. H.
,
Lederman
,
R. J.
, and
Kocaturk
,
O.
,
2012
, “
A Deflectable Guiding Catheter for Real-Time MRI-Guided Interventions
,”
J. Magn. Reson. Imaging
,
35
(
4
), pp.
908
915
.
9.
Fischer
,
H.
,
Vogel
,
B.
,
Pfleging
,
W.
, and
Besser
,
H.
,
1999
, “
Flexible Distal Tip Made of Nitinol (NiTi) for a Steerable Endoscopic Camera System
,”
J. Mater. Sci. Eng.: A
,
273–275
, pp.
780
783
.
10.
Haga
,
Y.
,
Muyari
,
Y.
,
Goto
,
S.
,
Matsunaga
,
T.
, and
Esashi
,
M.
,
2011
, “
Development of Minimally Invasive Medical Tools Using Laser Processing on Cylindrical Substrates
,”
Electr. Eng. Jpn.
,
176
(
1
), pp.
65
74
.
11.
Peirs
,
J.
,
Van Brussel
,
H.
,
Reynaerts
,
D.
, and
De Gersem
,
G.
,
2002
, “
A Flexible Distal Tip With Two Degrees of Freedom for Enhanced Dexterity in Endoscopic Robot Surgery
,”
13th Micromechanics Europe Workshop
(
MME
), Sinaia, Romania, Oct. 6–8, pp.
271
274
.http://citeseerx.ist.psu.edu/viewdoc/download?doi=10.1.1.557.1729&rep=rep1&type=pdf
12.
Ryu
,
S. C.
,
Renaud
,
P.
,
Black
,
R. J.
,
Daniel
,
B. L.
, and
Cutkosky
,
M. R.
,
2011
, “
Feasibility Study of an Optically Actuated MR-Compatible Active Needle
,”
IEEE/RSJ International Conference on Intelligent Robots and Systems
(
IROS
), San Francisco, CA, Sept. 25–30, pp.
2564
2569
.
13.
Gao
,
A.
,
Murphy
,
R.
,
Liu
,
H.
,
Iordachita
,
I.
, and
Armand
,
M.
,
2017
, “
Mechanical Model of Dexterous Continuum Manipulators With Compliant Joints and Tendon/External Force Interactions
,”
IEEE/ASME Trans. Mechatronics
,
22
(
1
), pp.
465
475
.
14.
Kutzer
,
M. D. M.
,
Segreti
,
S. M.
,
Brown
,
C. Y.
,
Taylor
,
R. H.
,
Mears
,
S. C.
, and
Armand
,
M.
,
2011
, “
Design of a New Cable-Driven Manipulator With a Large Open Lumen: Preliminary Applications in the Minimally-Invasive Removal of Osteolysis
,”
IEEE International Conference on Robotics and Automation
(
ICRA
), Shanghai, China, May 9–13, pp.
2913
2920
.
15.
Liu
,
J.
,
Hall
,
B.
,
Frecker
,
M.
, and
Reutzel
,
E. W.
,
2013
, “
Compliant Articulation Structure Using Superelastic Nitinol
,”
Smart Mater. Struct.
,
22
(
9
), p.
094018
.
16.
Wei
,
D.
,
Wenlong
,
Y.
,
Dawei
,
H.
, and
Zhijiang
,
D.
,
2012
, “
Modeling of Flexible Arm With Triangular Notches for Applications in Single Port Access Abdominal Surgery
,”
IEEE International Conference on Robotics and Biomimetics
(
ROBIO
), Guangzhou, China, Dec. 11–14, pp.
588
593
.
17.
Eastwood
,
K. W.
,
Bodani
,
V. P.
, and
Drake
,
J. M.
,
2016
, “
Three-Dimensional Simulation of Collision Free Paths for Combined Endoscopic Third Ventriculostomy and Pineal Region Tumor Biopsy: Implications for the Design Specifications of Future Flexible Endoscopic Instruments
,”
J. Oper. Neurosurg.
,
12
(
3
), pp.
231
238
.
18.
Lobontiu
,
N.
,
Cullin
,
M.
,
Petersen
,
T.
,
Alcazar
,
J. A.
, and
Member
,
S.
,
2014
, “
Planar Compliances of Symmetric Notch Flexure Hinges: The Right Circularly Corner-Filleted Parabolic Design
,”
IEEE Trans. Autom. Sci. Eng.
,
11
(
1
), pp.
169
176
.
19.
Cannon
,
J. R.
, and
Howell
,
L. L.
,
2005
, “
A Compliant Contact-Aided Revolute Joint
,”
Mech. Mach. Theory
,
40
(
11
), pp.
1273
1293
.
20.
Halverson
,
P. A.
, Howell, L. L., and
Bowden
,
A. E.
,
2008
, “A Flexure-Based Bi-Axial Contact-Aided Compliant Mechanism for Spinal Arthroplasty,”
ASME
Paper No. DETC2008-50121.
21.
Tummala
,
Y.
,
Wissa
,
A.
,
Frecker
,
M.
, and
Hubbard
,
J. E.
,
2014
, “
Design and Optimization of a Contact-Aided Compliant Mechanism for Passive Bending
,”
ASME J. Mech. Rob.
,
6
(
2
), p.
031013
.
22.
Mehta, V.,
Frecker
,
M.
, and
Lesieutre
,
G. A.
,
2009
, “Topology Optimization of Contact-Aided Compliant Cellular Mechanisms,”
ASME
Paper No. SMASIS2009-1367.
23.
Marcus
,
H. J.
,
Zareinia
,
K.
,
Gan
,
L. S.
,
Yang
,
F. W.
,
Lama
,
S.
,
Yang
,
G.-Z.
, and
Sutherland
,
G. R.
,
2014
, “
Forces Exerted During Microneurosurgery: A Cadaver Study
,”
Int. J. Med. Rob. Comput. Assisted Surg.
,
10
(
2
), pp.
251
256
.
24.
Bekeny
,
J. R.
,
Swaney
,
P. J.
,
Webster
,
R. J.
,
Russell
,
P. T.
, and
Weaver
,
K. D.
,
2013
, “
Forces Applied at the Skull Base During Transnasal Endoscopic Transsphenoidal Pituitary Tumor Excision
,”
J. Neurol. Surg., Part B
,
74
(
6
), pp.
337
341
.
You do not currently have access to this content.