Heat transfer and pressure drop characteristics of water flow in horizontal tubes with/without longitudinal inserts used as a heat exchanger tubing was experimentally studied. Testing was performed on bare tubes and tubes with square and rectangular as well as crossed-strip inserts with aspect ratios AR=1 and 4 and varied ratios of inlet mixed mean temperature to wall temperature of 0.88 to 0.97. The Reynolds number ranged from approximately 250 to 1750 for flow visualization and from 1700 to 4000 for the pressure drop and heat transfer measurements. Flow visualization, using a dye injection method, revealed a highly complex flow pattern including a secondary flow formed in the cross section for crossed-strip inserts. The thermal entrance length was found and correlated in terms of Re for this type of inserted tubes. The enhancement of heat transfer as compared to a conventional bare tube at the same Reynolds number based on the hydraulic diameter was found to be about a factor of 16 at Re⩽4000, while the friction factor rise was only about a factor of 4.5 at Re⩽4000. [S0022-1481(00)01303-7]

1.
Solanki, S.-C., Saini, J.-S., and Gupta, C.-P., 1985, “An Experimental Investigation of Fully Developed Laminar Flow in a Non-Circular Annulus,” Eighth National Conference on Heat Mass Transfer, HMTA 34-85, Visakhapatram.
2.
Solanki
,
S.-C.
,
Prekash
,
S.
,
Saini
,
J.-S.
, and
Gupta
,
C.-P.
,
1987
, “
Forced Convection Heat Transfer in Doubly Connected Ducts
,”
Int. J. Heat Fluid Flow
,
8
, pp.
107
110
.
3.
Chen
,
J.-D.
, and
Hsieh
,
S.-S.
,
1991
, “
Assessment Study of Longitudinal Rectangular Plate Inserts as Tubeside Heat Transfer Augmentative Device
,”
Int. J. Heat Mass Transf.
,
34
, pp.
2545
2553
.
4.
Hsieh
,
S.-S.
, and
Wen
,
M.-Y.
,
1996
, “
Developing Three-Dimensional Laminar Mixed Convection in a Circular Tube Inserted with Longitudinal Strips
,”
Int. J. Heat Mass Transf.
,
19
, pp.
299
310
.
5.
Wu, F.-Y., 1996, “Turbulent Flow and Pressure Drop in a Horizontal Circular Tube With Strip-Type Inserts,” Masters thesis, Department of Mechanical Engineering, National Sun Yat-Sen University (in Chinese).
6.
Liu, M.-H., 1996, “Turbulent Heat Transfer in a Horizontal Circular Tube With Strip-Type Inserts,” MS thesis, Department of Mechanical Engineering, National Sun Yat-Sen University (in Chinese).
7.
Hoyt
,
J. W.
, and
Sellin
,
R. H. J.
,
1997
, “
Flow Over Tube Banks: A Visualization Study
,”
ASME J. Fluids Eng.
,
119
, pp.
480
483
.
8.
Chen
,
J.-D.
, and
Hsieh
,
S.-S.
,
1992
, “
Laminar Forced Convection in Circular Duct Inserted with a Longitudinal Rectangular Plate
,”
AIAA J. Thermophys. Heat Transf.
,
6
, pp.
177
179
.
9.
Moffat
,
R. J.
,
1988
, “
Describing the Uncertainties in Experimental Results
,”
Exp. Therm. Fluid Sci.
,
1
, pp.
3
17
.
10.
Moody
,
L. F.
,
1944
, “
Friction Factor for Pipe Flow
,”
Trans. ASME
,
66
, pp.
671
684
.
11.
McAdams, W. H., 1954, Heat Transmission, 3rd Ed., McGraw-Hill, New York.
12.
Petukhov, B. S., 1970, “Heat Transfer and Friction in Turbulent Pipe Flow With Variable Physical Properties,” Advances in Heat Transfer, J. P. Hartnett and T. F. Irvine, eds., Academic Press, San Diego, CA, pp. 504–564.
You do not currently have access to this content.