Steady-state heat transfer and pressure drop data for single-phase viscous fluid flows (2 ≤ Re ≤ 400) in a single-pass U-type counterflow plate heat exchanger (PHE) with chevron plates are presented. With vegetable oil as test fluid (130 < Pr < 290), three different plate arrangements are employed: two symmetric (β = 30 deg/30 deg and 60 deg/60 deg) and one mixed (β = 30 deg/60 deg). The effects of chevron angle β, corrugation aspect ratio γ, and flow conditions (Re, Pr, μ/μw on Nu and f characteristics of the PHE are delineated. The results show a rather complex influence of plate surface corrugations on the enhanced thermal-hydraulic behavior. Relative to the performance of equivalent flat-plate packs, chevron plates sustain up to 2.9 times higher heat transfer rates on a fixed geometry and constant pumping power basis, and require up to 48 percent less surface area for the fixed heat load and pressure drop constraint.
Skip Nav Destination
e-mail: Raj.Manglik@uc.edu
Article navigation
Research Papers
Enhanced Heat Transfer Characteristics of Viscous Liquid Flows in a Chevron Plate Heat Exchanger
A. Muley,
A. Muley
Department of Mechanical, Industrial and Nuclear Engineering, University of Cincinnati, Cincinnati, OH 45221-0072
Search for other works by this author on:
R. M. Manglik,
R. M. Manglik
Department of Mechanical, Industrial and Nuclear Engineering, University of Cincinnati, Cincinnati, OH 45221-0072
e-mail: Raj.Manglik@uc.edu
Search for other works by this author on:
H. M. Metwally
H. M. Metwally
Department of Mechanical, Industrial and Nuclear Engineering, University of Cincinnati, Cincinnati, OH 45221-0072
Search for other works by this author on:
A. Muley
Department of Mechanical, Industrial and Nuclear Engineering, University of Cincinnati, Cincinnati, OH 45221-0072
R. M. Manglik
Department of Mechanical, Industrial and Nuclear Engineering, University of Cincinnati, Cincinnati, OH 45221-0072
e-mail: Raj.Manglik@uc.edu
H. M. Metwally
Department of Mechanical, Industrial and Nuclear Engineering, University of Cincinnati, Cincinnati, OH 45221-0072
J. Heat Transfer. Nov 1999, 121(4): 1011-1017 (7 pages)
Published Online: November 1, 1999
Article history
Received:
December 9, 1998
Revised:
June 25, 1999
Online:
December 5, 2007
Citation
Muley, A., Manglik, R. M., and Metwally, H. M. (November 1, 1999). "Enhanced Heat Transfer Characteristics of Viscous Liquid Flows in a Chevron Plate Heat Exchanger." ASME. J. Heat Transfer. November 1999; 121(4): 1011–1017. https://doi.org/10.1115/1.2826051
Download citation file:
Get Email Alerts
Cited By
Related Articles
Experimental Study of Turbulent Flow Heat Transfer and Pressure Drop in a Plate Heat Exchanger With Chevron Plates
J. Heat Transfer (February,1999)
Heat Transfer and Pressure Drop Characteristics of an Assembly of Partially Segmented Plates
J. Heat Transfer (February,1989)
Finite Analytic Solution of Convective Heat Transfer for Tube Arrays in Crossflow: Part I—Flow Field Analysis
J. Heat Transfer (August,1989)
Finite Analytic Solution of Convective Heat Transfer for Tube Arrays in Crossflow: Part II—Heat Transfer Analysis
J. Heat Transfer (August,1989)
Related Proceedings Papers
Related Chapters
Hydrodynamic Mass, Natural Frequencies and Mode Shapes
Flow-Induced Vibration Handbook for Nuclear and Process Equipment
Heat Transfer in a Heat Exchanger
Everyday Heat Transfer Problems: Sensitivities to Governing Variables
Heat Transfer and Pressure Drop Correlations for Compact Heat Exchangers with Multi-Region Louver Fins
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)