Readsorption occurs inside a sorbent-bed heat exchanger during the pressurization and depressurization processes, causing the adsorbate to be relocated from one end of the sorption bed heat exchanger to the other. In this paper, the readsorption processes are quantitatively determined for both the pressurization and depressurization processes in a sorbent-bed heat exchanger with a uniform initial temperature, loading, and pressure. Also, the readsorption that occurs during a typical operation of a two-bed sorption heat pump is quantified. The results show that the readsorption can cause as much as 30 percent of the ammonia in a sorbent-bed heat exchanger to be reallocated.

1.
Carslaw, H. S., and Jaeger, J. C, 1986, Conduction of Heat in Solid, Oxford Science Publications.
2.
Hajji
A.
,
Worek
W. M.
, and
Lavan
Z.
,
1989
, “
Numerical Simulation of a Regenerative Closed-Cycle Adsorption Cooling/Heating System
,”
ASME Journal of Solar Engineering
, Vol.
111
, pp.
339
346
.
3.
Hajji
A.
, and
Worek
W. M.
,
1990
, “
Simulation of a Regenerative Closed-Cycle Adsorption Cooling/Heating System
,”
Energy
, Vol.
16
, pp.
643
654
.
4.
Meunier
F.
,
1986
, “
Theoretical Performances of Solid Adsorbent Cascading Cycles Using the Zeolite-Water and Active Carbon-Methanol Pairs: Four Case Studies
,”
Heat Recovery Systems
, Vol.
6
, No.
6
, pp.
491
498
.
5.
Miles, D., and Shelton, S. V., 1991, “Coupled Heat Transfer and Thermodynamic Adsorption Heat Pump Analysis,” Heat Pump Design, Analysis, and Application, ASME AES-Vol. 26, pp. 33–38.
6.
Miller, E. B., 1929, “The Development of Silica Gel Refrigeration,” Journal of the American Society of Refrigerating Engineers, Vol. 17, No. 4.
7.
Sanborn, D. M., Miles, D. J., Nowakowski, G. A., and Shelton, S. V., 1992, “Gas-Fired Solid-Vapor Heat Pump Development,” Proceedings of the 1992 International Gas Research Conference, Vol. II, pp. 1362–1371.
8.
Shelton
S. V.
,
Wepfer
W. J.
, and
Miles
D. J.
,
1989
, “
Square Wave Analysis of the Solid/Vapor Heat Pump
,”
Heat Recovery Systems & CHP
, Vol.
9
, pp.
233
247
.
9.
Shelton
S. V.
,
Wepfer
W. J.
, and
Miles
D. J.
,
1990
, “
Ramp Wave Analysis of the Solid/Vapor Heat Pump
,”
ASME Journal of Energy Resources Technology
, Vol.
71
, pp.
69
78
.
10.
Turner, L., 1992, “Improvement of Activated Charcoal Ammonia Adsorption Heat Pumping/Refrigeration Cycles—Investigation of Porosity and Heat/Mass Transfer Characteristics,” Ph.D. Thesis, University of Warwick, Coventry, United Kingdom.
11.
Wave-Air, Inc., 1994, personal communication, 290 Fourteenth St., N. W., Atlanta, GA 30318.
12.
Zheng, W., 1993, “Heat and Mass Transfer Analysis of Closed-Cycle Solid Sorption Heat Pump,” Ph.D. Thesis, The University of Illinois at Chicago, Chicago, IL.
This content is only available via PDF.
You do not currently have access to this content.