J. Eng. Gas Turbines Power. April 2005, 127(2): 437–444.
Published Online: April 15, 2005
... effect on the bearing’s static force capacity. One C-core required approximately 340 W of power to generate 190 lb (845 N) of magnetic force at 538°C, however the magnetic air gap was much larger than at room temperature. The data presented are after bearing operation for eleven total hours at 538°C...