The distribution of water in the diffuser of a wet gas compressor is not well understood. Measurements of water film thickness across the diffuser surface would improve the understanding of two-phase flow phenomena in wet gas compressors. Electromagnetic probes were designed in order to measure water film thickness in the diffuser of a SwRI-designed wet gas compressor. The probes consisted of two electrode foils plated on a thin insulating substrate, allowing them to be bonded in place without drilling through the diffuser. An AC signal was passed between the electrodes, and the voltage across a resistor in series with the electrodes was recorded. As the water level covering the electrodes increased, the recorded voltage increased. A method of calibrating the probes was developed and used prior to installation in the diffuser. Testing showed the probes to be effective at detecting the presence of water in the diffuser and indicating the general water level. Improvements in probe design, calibration, and installation are needed to provide more precise water film thickness data.

References

1.
Bertoneri
,
M.
,
Duni
,
S.
,
Ransom
,
D.
,
Podesta
,
L.
,
Camatti
,
M.
,
Bigi
,
M.
, and
Wilcox
,
M.
,
2012
, “
Measured Performance of Two-Stage Centrifugal Compressor Under Wet Gas Conditions
,”
ASME
Paper No. GT2012-69819.
2.
Ransom
,
D.
,
Camatti
,
M.
,
Bertoneri
,
M.
,
Podesta
,
L.
,
Wilcox
,
M.
, and
Bigi
,
M.
,
2011
, “
Mechanical Performance of a Two Stage Centrifugal Compressor Under Wet Gas Conditions
,”
40th Turbomachinery Symposium
, Houston, TX, Sept. 12–15, pp.
121
128
.
3.
Hastings
,
E. C.
, and
Weinstein
,
L. M.
,
1984
, “
Preliminary Indications of Water Film Distribution and Thickness on an Airfoil in a Water Spray
,” NASA Langley Research Center, Hampton, VA, Technical Report No.
NASA-TM-85796
.https://ntrs.nasa.gov/search.jsp?R=19840019609
4.
Ozar
,
B.
,
Cetegen
,
B. M.
, and
Faghri
,
A.
,
2003
, “
Experiments on the Flow of a Thin Liquid Film Over a Horizontal Stationary and Rotating Disk Surface
,”
Exp. Fluids
,
34
(
5
), pp.
556
565
.
5.
Shedd
,
T. A.
, and
Newell
,
T. A.
,
1998
, “
An Automated Optical Liquid Film Thickness Measurement Method
,”
Rev. Sci. Instrum.
,
69
(
12
), pp.
4205
4213
.
6.
Krzeczkowski
,
S.
,
Kim
,
W.
,
Hammitt
,
F. G.
, and
Hwang
,
J. B.
,
1976
, “
Investigations of Secondary Liquid Phase Structure in Steam Wake
,” University of Michigan, Ann Arbor, MI, Report No.
UMICH 014571-1-T
.https://deepblue.lib.umich.edu/bitstream/handle/2027.42/6080/bac7432.0001.001.pdf?sequence=5
7.
Villeneuve
,
J. P.
, and
Ouellet
,
Y.
,
1978
, “
Laboratory Systems for Measuring Short-Term Changes in Water Levels
,”
Rev. Sci. Instrum.
,
49
(
10
), pp.
1425
1431
.
8.
Burns
,
J. R.
,
Ramshaw
,
C.
, and
Jachuck
,
R. J.
,
2003
, “
Measurement of Liquid Film Thickness and the Determination of Spin-Up Radius on a Rotating Disc Using an Electrical Resistance Technique
,”
Chem. Eng. Sci.
,
58
(
11
), pp.
2245
2253
.
9.
Brown
,
R. C.
,
Andreussi
,
P.
, and
Zanelli
,
S.
,
1978
, “
The Use of Wire Probes for the Measurement of Liquid Film Thickness in Annular Gas-Liquid Flows
,”
Can. J. Chem. Eng.
,
56
(
6
), pp.
754
757
.
You do not currently have access to this content.