This paper presents an offline fault diagnosis method for industrial gas turbines in a steady-state. Fault diagnosis plays an important role in the efforts for gas turbine owners to shift from preventive maintenance to predictive maintenance, and consequently to reduce the maintenance cost. Ever since its birth, numerous techniques have been researched in this field, yet none of them is completely better than the others and perfectly solves the problem. Fault diagnosis is a challenging problem because there are numerous fault situations that can possibly happen to a gas turbine, and multiple faults may occur in multiple components of the gas turbine simultaneously. An algorithm tailored to one fault situation may not perform well in other fault situations. A general algorithm that performs well in overall fault situations tends to compromise its accuracy in the individual fault situation. In addition to the issue of generality versus accuracy, another challenging aspect of fault diagnosis is that, data used in diagnosis contain errors. The data is comprised of measurements obtained from gas turbines. Measurements contain random errors and often systematic errors like sensor biases as well. In this paper, to maintain the generality and the accuracy together, multiple Bayesian models tailored to various fault situations are implemented in one hierarchical model. The fault situations include single faults occurring in a component, and multiple faults occurring in more than one component. In addition to faults occurring in the components of a gas turbine, sensor biases are explicitly included in the multiple models so that the magnitude of a bias, if any, can be estimated as well. Results from these multiple Bayesian models are averaged according to how much each model is supported by data. Gibbs sampling is used for the calculation of the Bayesian models. The presented method is applied to fault diagnosis of a gas turbine that is equipped with a faulty compressor and a biased fuel flow sensor. The presented method successfully diagnoses the magnitudes of the compressor fault and the fuel flow sensor bias with limited amount of data. It is also shown that averaging multiple models gives rise to more accurate and less uncertain results than using a single general model. By averaging multiple models, based on various fault situations, fault diagnosis can be general yet accurate.
Skip Nav Destination
e-mail: young.lee@aerospace.gatech.edu
e-mail: dmavris@ae.gatech.edu
e-mail: vvolovoi@ae.gatech.edu
e-mail: myuan@isye.gatech.edu
Article navigation
April 2010
Research Papers
A Fault Diagnosis Method for Industrial Gas Turbines Using Bayesian Data Analysis
Young K. Lee,
Young K. Lee
School of Aerospace Engineering,
e-mail: young.lee@aerospace.gatech.edu
Georgia Institute of Technology
, Atlanta, GA 30332-0150
Search for other works by this author on:
Dimitri N. Mavris,
Dimitri N. Mavris
School of Aerospace Engineering,
e-mail: dmavris@ae.gatech.edu
Georgia Institute of Technology
, Atlanta, GA 30332-0150
Search for other works by this author on:
Vitali V. Volovoi,
Vitali V. Volovoi
School of Aerospace Engineering,
e-mail: vvolovoi@ae.gatech.edu
Georgia Institute of Technology
, Atlanta, GA 30332-0150
Search for other works by this author on:
Ming Yuan,
Ming Yuan
School of Industrial and Systems Engineering,
e-mail: myuan@isye.gatech.edu
Georgia Institute of Technology
, Atlanta, GA 30332-0205
Search for other works by this author on:
Ted Fisher
Ted Fisher
Search for other works by this author on:
Young K. Lee
School of Aerospace Engineering,
Georgia Institute of Technology
, Atlanta, GA 30332-0150e-mail: young.lee@aerospace.gatech.edu
Dimitri N. Mavris
School of Aerospace Engineering,
Georgia Institute of Technology
, Atlanta, GA 30332-0150e-mail: dmavris@ae.gatech.edu
Vitali V. Volovoi
School of Aerospace Engineering,
Georgia Institute of Technology
, Atlanta, GA 30332-0150e-mail: vvolovoi@ae.gatech.edu
Ming Yuan
School of Industrial and Systems Engineering,
Georgia Institute of Technology
, Atlanta, GA 30332-0205e-mail: myuan@isye.gatech.edu
Ted Fisher
J. Eng. Gas Turbines Power. Apr 2010, 132(4): 041602 (6 pages)
Published Online: January 15, 2010
Article history
Received:
March 4, 2009
Revised:
June 2, 2009
Online:
January 15, 2010
Published:
January 15, 2010
Citation
Lee, Y. K., Mavris, D. N., Volovoi, V. V., Yuan, M., and Fisher, T. (January 15, 2010). "A Fault Diagnosis Method for Industrial Gas Turbines Using Bayesian Data Analysis." ASME. J. Eng. Gas Turbines Power. April 2010; 132(4): 041602. https://doi.org/10.1115/1.3204508
Download citation file:
Get Email Alerts
Temperature Dependence of Aerated Turbine Lubricating Oil Degradation from a Lab-Scale Test Rig
J. Eng. Gas Turbines Power
Multi-Disciplinary Surrogate-Based Optimization of a Compressor Rotor Blade Considering Ice Impact
J. Eng. Gas Turbines Power
Experimental Investigations on Carbon Segmented Seals With Smooth and Pocketed Pads
J. Eng. Gas Turbines Power
Related Articles
Nonlinear Fault Diagnosis of Jet Engines by Using a Multiple Model-Based Approach
J. Eng. Gas Turbines Power (January,2012)
Measurement Selections for Multicomponent Gas Path Diagnostics Using Analytical Approach and Measurement Subset Concept
J. Eng. Gas Turbines Power (November,2011)
A Demonstration of Artificial Neural-Networks-Based Data Mining for
Gas-Turbine-Driven Compressor Stations
J. Eng. Gas Turbines Power (April,2002)
Fault Detection and Identification in an IM270 Gas Turbine Using Measurements for Engine Control
J. Eng. Gas Turbines Power (October,2004)
Related Proceedings Papers
Related Chapters
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies
Performance Testing of Combined Cycle Power Plant
Handbook for Cogeneration and Combined Cycle Power Plants, Second Edition
The Special Characteristics of Closed-Cycle Gas Turbines
Closed-Cycle Gas Turbines: Operating Experience and Future Potential