Radial loads and direction of a centrifugal gas compressor containing a high specific speed mixed flow impeller and a single tongue volute were determined both experimentally and computationally at both design and off-design conditions. The experimental methodology was developed in conjunction with a traditional ASME PTC-10 closed-loop test to determine radial load and direction. The experimental study is detailed in Part 1 of this paper (Moore and Flathers, 1998). The computational method employs a commercially available, fully three-dimensional viscous code to analyze the impeller and the volute interaction. An uncoupled scheme was initially used where the impeller and volute were analyzed as separate models using a common vaneless diffuser geometry. The two calculations were then repeated until the boundary conditions at a chosen location in the common vaneless diffuser were nearly the same. Subsequently, a coupled scheme was used where the entire stage geometry was analyzed in one calculation, thus eliminating the need for manual iteration of the two independent calculations. In addition to radial load and direction information, this computational procedure also provided aerodynamic stage performance. The effect of impeller front face and rear face cavities was also quantified. The paper will discuss computational procedures, including grid generation and boundary conditions, as well as comparisons of the various computational schemes to experiment. The results of this study will show the limitations and benefits of Computational Fluid Dynamics (CFD) for determination of radial load, direction, and aerodynamic stage performance.
Skip Nav Destination
Article navigation
October 1999
Research Papers
Aerodynamically Induced Radial Forces in a Centrifugal Gas Compressor: Part 2—Computational Investigation
M. B. Flathers,
M. B. Flathers
Solar Turbines Inc., 9330 Skypark Court, San Diego, CA 92123
Search for other works by this author on:
G. E. Bache´
G. E. Bache´
Advanced Scientific Computing Corporation, EI Dorado Hills, CA
Search for other works by this author on:
M. B. Flathers
Solar Turbines Inc., 9330 Skypark Court, San Diego, CA 92123
G. E. Bache´
Advanced Scientific Computing Corporation, EI Dorado Hills, CA
J. Eng. Gas Turbines Power. Oct 1999, 121(4): 725-734 (10 pages)
Published Online: October 1, 1999
Article history
Received:
March 3, 1997
Online:
December 3, 2007
Connected Content
Citation
Flathers, M. B., and Bache´, G. E. (October 1, 1999). "Aerodynamically Induced Radial Forces in a Centrifugal Gas Compressor: Part 2—Computational Investigation." ASME. J. Eng. Gas Turbines Power. October 1999; 121(4): 725–734. https://doi.org/10.1115/1.2818533
Download citation file:
Get Email Alerts
An Experimental Study on the Effect of Intake Pressure on a Natural Gas-Diesel Dual-Fuel Engine
J. Eng. Gas Turbines Power
Related Articles
Numerical Optimization of a Vaned Shroud Design for Increased
Operability Margin in Modern Centrifugal Compressors
J. Turbomach (October,2006)
An Experimental and Computational Investigation of Flow in a Radial Inlet of an Industrial Pipeline Centrifugal Compressor
J. Turbomach (April,1996)
Effects of Impeller Squealer Tip on Centrifugal Compressor Performance
J. Eng. Gas Turbines Power (March,2017)
Related Proceedings Papers
Related Chapters
Introduction
Design of Mechanical Bearings in Cardiac Assist Devices
Dynamic Behavior of Pumping Systems
Pipeline Pumping and Compression Systems: A Practical Approach
Hydrodynamic Lubrication
Design of Mechanical Bearings in Cardiac Assist Devices