The leakage performance of a brush seal with gaseous working fluids at static and low rotor speed conditions was investigated. This report includes the leakage results for air, helium, and carbon dioxide at several bristle/rotor interferences. In addition, the effects of packing a lubricant into the bristles and also of reversing the pressure drop across the seal were investigated. Results were compared to that of an annular seal at similar operating conditions. In order to generalize the results, they were correlated using corresponding state theory. The brush seal tested had a bore diameter of 3.792 cm (1.4930 in.), a fence height of 0.0635 cm (0.025 in.), and 1800 bristles/cm-circumference (4500 bristles/in.-circumference). Various bristle/rotor radial interferences were achieved by using a tapered rotor. The brush seal reduced the leakage in comparison with the annular seal, up to 9.5 times. Reversing the pressure drop across the brush seal produced leakage rates approximately the same as that of the annular seal. Addition of a lubricant reduced the leakage by 2.5 times when compared to a nonlubricated brush seal. The air and carbon dioxide data were successfully correlated using the corresponding state theory. However, the helium data followed a different curve from the air and carbon dioxide data.
Skip Nav Destination
Article navigation
April 1993
Research Papers
Brush Seal Leakage Performance With Gaseous Working Fluids at Static and Low Rotor Speed Conditions
J. A. Carlile,
J. A. Carlile
NASA Lewis Research Center, Cleveland, OH 44135
Search for other works by this author on:
R. C. Hendricks,
R. C. Hendricks
NASA Lewis Research Center, Cleveland, OH 44135
Search for other works by this author on:
D. A. Yoder
D. A. Yoder
NASA Lewis Research Center, Cleveland, OH 44135
Search for other works by this author on:
J. A. Carlile
NASA Lewis Research Center, Cleveland, OH 44135
R. C. Hendricks
NASA Lewis Research Center, Cleveland, OH 44135
D. A. Yoder
NASA Lewis Research Center, Cleveland, OH 44135
J. Eng. Gas Turbines Power. Apr 1993, 115(2): 397-403 (7 pages)
Published Online: April 1, 1993
Article history
Received:
February 24, 1992
Online:
April 24, 2008
Citation
Carlile, J. A., Hendricks, R. C., and Yoder, D. A. (April 1, 1993). "Brush Seal Leakage Performance With Gaseous Working Fluids at Static and Low Rotor Speed Conditions." ASME. J. Eng. Gas Turbines Power. April 1993; 115(2): 397–403. https://doi.org/10.1115/1.2906722
Download citation file:
Get Email Alerts
Burner and Flame Transfer Matrices of Jet Stabilized Flames: Influence of Jet Velocity and Fuel Properties
J. Eng. Gas Turbines Power
Towards Low NOx Emissions Performance of A 65KW Recuperated Gas Turbine Operated on 100% Hydrogen
J. Eng. Gas Turbines Power
A Large Eddy Simulation Study on Hydrogen Microjets in Hot Vitiated Crossflow
J. Eng. Gas Turbines Power
Related Articles
Lubricant-Derived Ash Properties and Their Effects on Diesel Particulate Filter Pressure-Drop Performance
J. Eng. Gas Turbines Power (March,2011)
Performance of a Modified Packed-Gland Seal
J. of Lubrication Tech (April,1968)
On the Modeling of Gas and Liquid Leaks Through Packed Glands
J. Pressure Vessel Technol (October,2022)
Leakage Estimate in Nonuniformly Compressed Packing Rings
ASME J of Nuclear Rad Sci (April,2020)
Related Chapters
Thermodynamic Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
The Thermo —Mechanical Analysis of Mechanical Packing (SEAL), Using Finite Element Method (FEM) — Results and Conclusions
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)
Natural Gas Transmission
Pipeline Design & Construction: A Practical Approach, Third Edition