Cold-flow spray researchers have an array of diagnostic tools to extract meaningful information on spray characteristics. The efficacy of many of these tools, however, depends heavily on calibration, alignment, human operation, and even the underlying operational theory. This can lead to large discrepancies in data values for seemingly identical setups between workers. The application of experimental data to numerical models is thereby hindered due to inconsistencies in results caused by experimental error. Previously, an attempt was made to produce a “reference spray” through the use of a research simplex atomizer (RSA). As manufacturing processes and diagnostic tools have improved, the RSA is being revisited. Here, a new RSA has been investigated. Fundamental datasets captured from detailed test conditions are presented to provide benchmark data with the intention of other workers testing the reproducibility of the results. Preliminary findings between laboratories show good agreement in droplet size measurements. Further, emphasis is placed on the sensitivity of laser diagnostics used and the effect their operation can incur. To satisfy the requirements of a measurement reference, it is paramount that all workers adhere to similar diagnostic configurations and detail their operating parameters.
Skip Nav Destination
Article navigation
December 2019
Research-Article
Preliminary Development of a Measurement Reference Using a Research Simplex Atomizer
Vincent G. McDonell,
Vincent G. McDonell
1Corresponding author.
Search for other works by this author on:
Scott Samuelsen
Scott Samuelsen
Search for other works by this author on:
Scott B. Leask
Alice K. Li
Vincent G. McDonell
Scott Samuelsen
1Corresponding author.
Contributed by the Fluids Engineering Division of ASME for publication in the JOURNAL OF FLUIDS ENGINEERING. Manuscript received February 10, 2019; final manuscript received June 10, 2019; published online July 12, 2019. Assoc. Editor: Meredith Metzer.
J. Fluids Eng. Dec 2019, 141(12): 121407 (11 pages)
Published Online: July 12, 2019
Article history
Received:
February 10, 2019
Revised:
June 10, 2019
Citation
Leask, S. B., Li, A. K., McDonell, V. G., and Samuelsen, S. (July 12, 2019). "Preliminary Development of a Measurement Reference Using a Research Simplex Atomizer." ASME. J. Fluids Eng. December 2019; 141(12): 121407. https://doi.org/10.1115/1.4044072
Download citation file:
Get Email Alerts
Cited By
Related Articles
Experimental and Analytical Characterization of Alternative Aviation Fuel Sprays Under Realistic Operating Conditions
J. Eng. Gas Turbines Power (June,2019)
Forced Low-Frequency Spray Characteristics of a Generic Airblast Swirl Diffusion Burner
J. Eng. Gas Turbines Power (April,2005)
Validation of an Infrared Extinction Method for Fuel Vapor Concentration Measurements Towards the Systematic Comparison Between Alternative and Conventional Fuels for Aviation
J. Eng. Gas Turbines Power (January,2012)
Drop Size Distribution and Air Velocity Measurements in Air Assist Swirl Atomizer Sprays
J. Fluids Eng (March,1987)
Related Proceedings Papers
Related Chapters
A New Boom Mechanism Design for Corn Sprayer
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)
Internal and Near Nozzle Flow Simulations of Gasoline Multi-Hole Injector (ECN Spray G) with Transient Needle Motion
Proceedings of the 10th International Symposium on Cavitation (CAV2018)
Numerical Simulation of Nucleate Spray Cooling: Effect of Droplet Impact on Bubble Growth and Heat Transfer in a Thin Liquid Film
Inaugural US-EU-China Thermophysics Conference-Renewable Energy 2009 (UECTC 2009 Proceedings)