The accuracy of piezoelectric test system has a direct influence on the accuracy of the vector force detection. Piezoelectric sensor parameters are obtained by calibration system calibrated through orthogonal calibration method. Accuracy of the application of field test lacks the corresponding theoretical basis, resulting in test system test accuracy is questioned. In this paper, piezoelectric force test system is used as the research object. In order to verify accuracy of piezoelectric test system through calibration of orthogonal calibration method, a variable angle deflection loading device was designed. An incremental calibration method for thrust test is put forward by applying vector force at different angles. Based on vector force coordinate transformation matrix, a deflection load test and analysis model are established. The vector force coordinates transformation matrix is used to calculate the experimental data obtained from the deviation angle test system, and the deviation of the vector force value is obtained. Finally, the accuracy, effectiveness and rationality of piezoelectric test system through the orthogonal calibration method are verified.

References

1.
Cedraro
,
A.
,
Cappello
,
A.
, and
Chiari
,
L.
,
2008
, “
A Portable System for in-Situ Re-Calibration of Force Platforms: Theoretical Validation
,”
Gait Posture
,
29
(
3
), pp.
449
453
.
2.
Wu
,
B.
, and
Cai
,
P.
,
2013
, “
Decoupling Analysis of a Sliding Structure Six-Axis Force/Torque Sensor
,”
Meas. Sci. Rev.
,
13
(
4
), pp.
187
193
.
3.
Sun
,
Y.
,
Liu
,
Y.
,
Zou
,
T.
,
Jin
,
M.
, and
Liu
,
H.
,.
2015
, “
Design and Optimization of a Novel Six-Axis Force/Torque Sensor for Space Robot
,”
Measurement
,
65
, pp.
135
148
.
4.
Xing
,
Q.
,
Jun
,
Z.
,
Min
,
Q.
,
Zhenyuan
,
J.
, and
Baoyuan
,
S.
,
2011
, “
Design, Calibration and Error Analysis of a Piezoelectric Thrust Dynamometer for Small Thrust Liquid Pulsed Rocket Engines
,”
Measurement
,
44
(
2
), pp.
338
340
.
5.
Wright
,
A. M.
,
Wright
,
A. B.
,
Born
,
T.
, and
Strickland
,
R.
,
2013
, “
A Six Degree-of-Freedom Thrust Sensor for a Labscale Hybrid Rocket
,”
Meas. Sci. Technol.
,
24
(
24
), p.
5104
.
6.
Milos
,
P.
,
Davidovic
,
N.
,
Jojic
,
B.
,
Milos
,
M.
, and
Todic
,
I.
,
2015
, “
A Novel 6 DOF Thrust Vector Control Test Stand
,”
Tehnicki vjesnik—Tech. Gazette
,
22
(
5
), pp.
1247
1254
.
7.
Pramanik
,
C.
,
Islam
,
T.
, and
Saha
,
H.
,
2006
, “
Temperature Compensation of Piezoresistive Micro-Machined Porous Silicon Pressure Sensor by Ann
,”
Microelectron. Reliab.
,
46
(
2–4
), pp.
343
351
.
8.
Shilin
,
X.
,
Shenglai
,
C.
,
Xinong
,
Z.
, and
Changchun
,
Z.
,
2010
, “
Neural Network Hybrid Modeling Method for Transducer Calibration
,”
J. Mech. Eng.
,
46
(
22
), pp.
6
15
.
9.
Min
,
Y.
,
2013
, “
The Calibration Method of a Large Six-Axis Force Sensors
,”
Adv. Mater. Res.
,
4
, pp.
753
755
.
10.
Faber
,
G. S.
,
Chang
,
C.-C.
,
Kingma
,
I.
,
Martin Schepers
,
H.
,
Herber
,
S.
,
Veltink
,
P. H.
, and
Dennerlein
,
J. T.
,
2012
, “
A Force Plate Based Method for the Calibration of Force/Torque Sensors
,”
J. Biomech.
,
45
(
7
), pp.
1332
1338
.
11.
Roozbahani
,
H.
,
Alireza
,
F.
,
Heikki
,
H.
, and
Heikki
,
H.
,
2013
, “
Novel Online Re-Calibration Method for Multi-Axis Force/Torque Sensor of ITER Welding/Machining Robot
,”
IEEE Sens. J.
,
13
(
11
), pp.
4432
4443
.
12.
Liu
,
W.
,
Li
,
Y.-J.
,
Jia
,
Z.-Y.
,
Jun
,
Z.
, and
Min
,
Q.
,
2011
, “
Research on Parallel Load Sharing Principle of Piezoelectric Six-Dimensional Heavy Force/Torque Sensor
,”
Mech. Syst. Signal Process.
,
25
(
1
), pp.
331
343
.
13.
Fang
,
Q.
,
Zhang
,
J.
,
Li
,
Y.
, and
Jia
,
Z.
,
2011
, “
Study of Load-Distribution of Piezoelectric Six-Axis Heavy Force Dynamometer on Shaft
,”
Chin. J. Sci. Instrum.
,
32
(
2
), pp.
439
444
.
14.
Li
,
Y. J.
,
Wang
,
G. C.
,
Yang
,
X.
,
Zhang
,
H.
,
Han
,
B. B.
, and
Zhang
,
Y. L.
,
2018
, “
Research on Static Decoupling Algorithm for Piezoelectric Six Axis Force/Torque Sensor Based on LSSVR Fusion Algorithm
,”
Mech. Syst. Signal Process.
,
110
, pp.
509
520
.
15.
Tian
,
Y.
,
Zhang
,
J.
,
Ren
,
Z.
,
Liu
,
W.
,
Jia
,
Z.
, and
Chang
,
Q.
,
2018
, “
A Novel Calibration Method Based on Kirchhoff Theory for Piezoelectric Dynamometer
,”
Sensor Rev.
,
38
(
2
), pp.
137
145
.
You do not currently have access to this content.