A robust unknown input observer for a nonlinear system whose nonlinear function satisfies the Lipschitz condition is designed based on linear matrix inequality approach. Both noise and uncertainties are taken into account in deriving the observer. A component fault detection and isolation scheme based on these observers is proposed. The effectiveness of the observer and the fault diagnosis scheme is shown by applying them for component fault diagnosis of an electrohydraulic actuator.

1.
Rajamani
,
R.
, and
Ganguli
,
A.
, 2004, “
Sensor Fault Diagnosis for a Class of Non-Linear Systems Using Linear Matrix Inequalities
,”
Int. J. Control
0020-7179,
77
(
10
), pp.
920
930
.
2.
Wang
,
H. B.
,
Wang
,
J. L.
, and
Lam
,
J.
, 2007, “
Robust Fault Detection Observer Design: Iterative LMI Approaches
,”
ASME J. Dyn. Syst., Meas., Control
0022-0434,
129
, pp.
77
82
.
3.
Chen
,
W.
, and
Saif
,
M.
, 2006, “
Unknown Input Observer Design for a Class of Nonlinear Systems: an LMI Approach
,”
Proceedings of the American Control Conference
,
Minneapolis, MN
, pp.
834
838
.
4.
Darouach
,
M.
,
Zasadzinski
,
M.
, and
Xu
,
S. J.
, 1994, “
Full Order Observers for Linear Systems With Unknown Inputs
,”
IEEE Trans. Autom. Control
0018-9286,
39
(
2
), pp.
606
609
.
5.
Koenig
,
D.
, and
Mammar
,
S.
, 2001, “
Design of a class of Reduced Order Unknown Inputs Nonlinear Observer for Fault Diagnosis
,”
Proceedings of the American Control Conference
,
Arlington, VA
, pp.
2143
2147
.
6.
Pertew
,
A. M.
,
Marquez
,
H. J.
, and
Zhao
,
Q.
, 2005, “
H∞ Synthesis of Unknown Input Observers for Non-Linear Lipschitz Systems
,”
Int. J. Control
0020-7179,
78
(
15
), pp.
1155
1165
.
7.
Seliger
,
R.
, and
Frank
,
P. M.
, 1991, “
Robust Component Fault Detection and Isolation in Nonlinear Dynamic Systems Using Nonlinear Unknown Input Observer
,”
Proceedings of the IFAC/IMACS Symposium SAFEPROCESS’91
,
Baden-Baden, Germany
, pp.
313
318
.
8.
Mondal
,
S.
,
Chakraborty
,
G.
, and
Bhattacharyya
,
K.
, 2007, “
A Full Order Luenberger-Like Observer for Nonlinear Systems With Unknown Inputs
,”
Proceedings of ACODS’2007
,
Bangalore, India
, pp.
117
120
.
9.
Zhong
,
M.
,
Ding
,
S. X.
,
Bingyong
,
T.
,
Jeinsch
,
T.
, and
Sader
,
M.
, 2002, “
An LMI Approach to Design Robust Fault Detection Observers
,”
Proceedings of the Forth World Congress on Intelligent Control and Automation
,
Shanghai, P.R.C.
, pp.
2705
2709
.
10.
Zhong
,
M.
,
Ding
,
S. X.
,
Lam
,
J.
, and
Wang
,
H.
, 2003, “
An LMI Approach to Design Robust Fault Detection Filter for Uncertain LTI Systems
,”
Automatica
0005-1098,
39
(
3
), pp.
543
550
.
11.
Koenig
,
D.
, 2006, “
Observer Design for Unknown Input Nonlinear Descriptor Systems Via Convex Optimization
,”
IEEE Trans. Autom. Control
0018-9286,
51
(
6
), pp.
1047
1052
.
12.
Frank
,
P. M.
, 1994, “
On-Line Fault Detection in Uncertain Nonlinear Systems Using Diagnosis Observers: A Survey
,”
Int. J. Syst. Sci.
0020-7721,
25
(
12
), pp.
2155
2166
.
13.
Bloch
,
G.
,
Ouladsine
,
M.
, and
Thomas
,
P.
, 1995, “
On-Line Fault Diagnosis of Dynamic Systems Via Robust Parameter Estimation
,”
Control Eng. Pract.
0967-0661,
3
(
12
), pp.
1709
1717
.
14.
Boyd
,
S.
,
El Ghaoui
,
L.
,
Feron
,
E.
, and
Balakrishnan
,
V.
, 1994,
Linear Matrix Inequalities in Systems and Control Theory
,
SIAM
,
Philadelphia, PA
.
15.
Liu
,
R.
, and
Alleyne
,
A.
, 2000, “
Nonlinear Force/Pressure Tracking of an Electro-Hydraulic Actuator
,”
ASME J. Dyn. Syst., Meas., Control
0022-0434,
122
, pp.
232
237
.