A membrane-based humidifier that uses cooling water of a fuel cell system to humidify the inlet air is modeled and analyzed in this paper. This four-state lumped model is simple and yet captures the humidification behavior accurately. A peculiar characteristic of this system is the fact that it exhibits nonminimum-phase (NMP) behavior. The reason the NMP behavior exists and the effect of system parameters on the location of the NMP zero are analyzed. A proportional control algorithm is proposed to reject the effect of system disturbances, and a feed-forward algorithm is developed to ensure proper humidifier operation under air flow rate changes. Because the NMP zero exists in the disturbance-to-output loop, the proposed algorithm was found to successfully eliminate the undershoot phenomena associated with the NMP zero. However, the disturbance-to-output loop is coupled with input-to-output loop, and the NMP zero could affect the feedback control design.
Skip Nav Destination
e-mail: hpeng@umich.edu
Article navigation
July 2008
Technical Briefs
Nonminimum-Phase Phenomenon of PEM Fuel Cell Membrane Humidifiers
Dongmei Chen,
Dongmei Chen
Department of Mechanical Engineering,
University of Michigan
, Ann Arbor, MI 48109-2125
Search for other works by this author on:
Huei Peng
Huei Peng
Professor
Department of Mechanical Engineering,
e-mail: hpeng@umich.edu
University of Michigan
, Ann Arbor, MI 48109-2125
Search for other works by this author on:
Dongmei Chen
Department of Mechanical Engineering,
University of Michigan
, Ann Arbor, MI 48109-2125
Huei Peng
Professor
Department of Mechanical Engineering,
University of Michigan
, Ann Arbor, MI 48109-2125e-mail: hpeng@umich.edu
J. Dyn. Sys., Meas., Control. Jul 2008, 130(4): 044501 (9 pages)
Published Online: June 4, 2008
Article history
Received:
March 4, 2005
Revised:
February 3, 2008
Published:
June 4, 2008
Citation
Chen, D., and Peng, H. (June 4, 2008). "Nonminimum-Phase Phenomenon of PEM Fuel Cell Membrane Humidifiers." ASME. J. Dyn. Sys., Meas., Control. July 2008; 130(4): 044501. https://doi.org/10.1115/1.2936381
Download citation file:
Get Email Alerts
Cited By
Fault detection of automotive engine system based on Canonical Variate Analysis combined with Bhattacharyya Distance
J. Dyn. Sys., Meas., Control
Multi Combustor Turbine Engine Acceleration Process Control Law Design
J. Dyn. Sys., Meas., Control (July 2025)
Related Articles
A Thermodynamic Model of Membrane Humidifiers for PEM Fuel Cell Humidification Control
J. Dyn. Sys., Meas., Control (September,2005)
A Controllable Membrane-Type Humidifier for Fuel Cell Applications—Part I: Operation, Modeling and Experimental Validation
J. Fuel Cell Sci. Technol (October,2010)
The Effects of Membrane Properties and Structural Parameters on the Non-Minimum Phase Behavior of the PEM Fuel Cell Humidification System
J. Fuel Cell Sci. Technol (February,2012)
Use of Optimal Controls to Mitigate Competing Performance Objectives in a Polymer Electrolyte Membrane Fuel Cell System
J. Fuel Cell Sci. Technol (August,2009)
Related Proceedings Papers
Related Chapters
Scope of Section I, Organization, and Service Limits
Power Boilers: A Guide to the Section I of the ASME Boiler and Pressure Vessel Code, Second Edition
Computation of Gradient and Hessian in Feed-Forward Neural Networks: A Variational Approach
Intelligent Engineering Systems Through Artificial Neural Networks, Volume 17
Comparison of Feed-Forward Schemes for Anti-Sway Control of Rotary Crane
International Conference on Advanced Computer Theory and Engineering (ICACTE 2009)