This paper deals with multilevel control and optimization of a chiller system. The system consists of multiple chillers, feed pumps, and cooling towers. A multilevel control structure is presented. The first level contains control loops for chilled water temperature, vane position, and condenser water temperature. Second level controls provide supervisory adjustments of set points of first level controls. Third level is optimum load allocation of chillers and pumps. A fourth level supervisory deals with the coordination of conflicting goals of subsystems to provide a load strategy. Performance analysis (monitoring, trouble shooting) are also presented. A digital and distributed control system is utilized for implementation. The distributed system has a flexible architecture compatible for each level of control sophistication. It offers simple function blocks for digital control of first-level loops, as well as, the higher levels without any need of computer programming.
Skip Nav Destination
Article navigation
December 1985
Research Papers
Energy Management of Chillers by Multilevel Control and Optimization
A. Kaya
The University of Akron, Akron, Ohio 44325
A. Sommer
Bailey Controls Company, Wickliffe, Ohio
J. Dyn. Sys., Meas., Control. Dec 1985, 107(4): 270-277 (8 pages)
Published Online: December 1, 1985
Article history
Received:
June 1, 1984
Online:
July 21, 2009
Citation
Kaya, A., and Sommer, A. (December 1, 1985). "Energy Management of Chillers by Multilevel Control and Optimization." ASME. J. Dyn. Sys., Meas., Control. December 1985; 107(4): 270–277. https://doi.org/10.1115/1.3140735
Download citation file:
Get Email Alerts
Cited By
Control of Autonomous Vehicles via Multi-Stage Linear Feedback Design
J. Dyn. Sys., Meas., Control
Co-Optimization of Design and Control of Energy Efficient Hybrid Electric Vehicles Using Coordination Schemes
J. Dyn. Sys., Meas., Control
Computationally Efficient Hierarchical Mpc via Koopman Operator
J. Dyn. Sys., Meas., Control
Balancing a Stick with Eyes Shut: Inverted Pendulum On a Cart Without Angle Measurement
J. Dyn. Sys., Meas., Control
Related Articles
A Multivariable Newton-Based Extremum Seeking Control for Condenser Water Loop Optimization of Chilled-Water Plant
J. Dyn. Sys., Meas., Control (November,2015)
The Performances of Internal Helical-Rib Roughness Tubes Under Fouling Conditions: Practical Cooling Tower Water Fouling and Accelerated Particulate Fouling
J. Heat Transfer (August,2003)
Analysis of Bolted Joints with Nonlinear Gasket Behavior
J. Pressure Vessel Technol (August,1980)
Experimental Testing of Gerotor and Scroll Expanders Used in, and Energetic and Exergetic Modeling of, an Organic Rankine Cycle
J. Energy Resour. Technol (March,2009)
Related Chapters
Condensers and Cooling Towers
Handbook for Cogeneration and Combined Cycle Power Plants, Second Edition
Basics of Hydraulic Loops
Hydraulics, Pipe Flow, Industrial HVAC & Utility Systems: Mister Mech Mentor, Vol. 1
Optimization of Supply and Return Water Temperature of Single-Pipe Cross-Over Heating System for Energy Saving Reconstructed Building
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3