Skip Nav Destination
Issues
November 1995
ISSN 0148-0731
EISSN 1528-8951
In this Issue
Technical Papers
A New Load Application System for In Vitro Study of Ligamentous Injuries to the Human Knee Joint
J Biomech Eng. November 1995, 117(4): 373–382.
doi: https://doi.org/10.1115/1.2794195
Topics:
Knee
,
Stress
,
Wounds
,
Degrees of freedom
,
Servomechanisms
,
Design
,
Valves
,
Computers
,
Control equipment
,
Displacement measurement
A Six-Degree-of-Freedom Test System for the Study of Joint Mechanics and Ligament Forces
J Biomech Eng. November 1995, 117(4): 383–389.
doi: https://doi.org/10.1115/1.2794196
Topics:
Degrees of freedom
,
Feedback
,
Joint mechanics
,
Linkages
,
Stress
,
Testing
Confined Compression of Canine Annulus Fibrosus Under Chemical and Mechanical Loading
J Biomech Eng. November 1995, 117(4): 390–396.
doi: https://doi.org/10.1115/1.2794197
Topics:
Annulus
,
Compression
,
Displacement
Physical Response of Collagen Gels to Tensile Strain
J Biomech Eng. November 1995, 117(4): 397–401.
doi: https://doi.org/10.1115/1.2794198
Topics:
Actuators
,
Density
,
Endothelial cells
,
Fibroblasts
,
Rheology
,
Servomechanisms
,
Steady state
,
Stiffness
,
Structural elements (Construction)
,
Tension
Mechanical Responses of the Rabbit Patello-Femoral Joint to Blunt Impact
J Biomech Eng. November 1995, 117(4): 402–408.
doi: https://doi.org/10.1115/1.2794199
Topics:
Biological tissues
,
Bone
,
Cartilage
,
Damage
,
Pressure
,
Pressure gradient
,
Probes
,
Surgery
Energy-Shunting Hip Padding System Attenuates Femoral Impact Force in a Simulated Fall
J Biomech Eng. November 1995, 117(4): 409–413.
doi: https://doi.org/10.1115/1.2794200
Topics:
Cushioning materials
,
Soft tissues
,
Fracture (Materials)
,
Fracture (Process)
,
Hip fractures
,
Stiffness
,
Damping
,
Design
,
Pendulums
,
Shear (Mechanics)
Hindered Transport of Macromolecules Through a Single Row of Cylinders: Application to Glomerular Filtration
J Biomech Eng. November 1995, 117(4): 414–422.
doi: https://doi.org/10.1115/1.2794202
Topics:
Cylinders
,
Filtration
,
Macromolecules
,
Diaphragms (Mechanical devices)
,
Diaphragms (Structural)
,
Fibers
,
Membranes
,
Dimensions
,
Kidney
,
Particulate matter
Hemodynamics of the Fontan Connection: An In-Vitro Study
Young H. Kim, P. G. Walker, A. A. Fontaine, S. Panchal, A. E. Ensley, J. Oshinski, S. Sharma, B. Ha, C. L. Lucas, A. P. Yoganathan
J Biomech Eng. November 1995, 117(4): 423–428.
doi: https://doi.org/10.1115/1.2794203
Topics:
Blood
,
Design
,
Flow (Dynamics)
,
Flow visualization
,
Geometry
,
Glass
,
Hemodynamics
,
Lung
,
Magnetic resonance
,
Pressure
Numerical Simulation of Airflow in the Human Nasal Cavity
J Biomech Eng. November 1995, 117(4): 429–441.
doi: https://doi.org/10.1115/1.2794204
Separation Surfaces for Laminar Flow in Branching Tubes—Effect of Reynolds Number and Geometry
J Biomech Eng. November 1995, 117(4): 442–447.
doi: https://doi.org/10.1115/1.2794205
Topics:
Geometry
,
Laminar flow
,
Reynolds number
,
Separation (Technology)
,
Shapes
,
Flow (Dynamics)
,
Bifurcation
,
Flow visualization
,
Junctions
Peristaltic Pumping in a Circular Tube in the Presence of an Eccentric Catheter
J Biomech Eng. November 1995, 117(4): 448–454.
doi: https://doi.org/10.1115/1.2794206
Topics:
Catheters
,
Pressure
,
Deformation
,
Reynolds number
,
Wavelength
,
Waves
Variations in Rupture Site and Surface Strains at Failure in the Maturing Rabbit Medial Collateral Ligament
J Biomech Eng. November 1995, 117(4): 455–461.
doi: https://doi.org/10.1115/1.2794207
Topics:
Failure
,
Rupture
,
Bone
,
Biological tissues
,
Dimensions
,
Strain measurement
,
Tension
,
Testing
Analysis of Thermal Injury Process Based on Enzyme Deactivation Mechanisms
J Biomech Eng. November 1995, 117(4): 462–465.
doi: https://doi.org/10.1115/1.2794208
Topics:
Enzymes
,
Wounds
,
Damage
,
Biological tissues
,
Proteins
,
Temperature
Energy Comparison Between Trot, Bound, and Gallop Using a Simple Model
J Biomech Eng. November 1995, 117(4): 466–473.
doi: https://doi.org/10.1115/1.2794209
Cervical Vertebral Strain Measurements Under Axial and Eccentric Loading
J Biomech Eng. November 1995, 117(4): 474–478.
doi: https://doi.org/10.1115/1.2794210
Topics:
Cervical spine
,
Compression
,
Deformation
,
Failure
,
Load bearing capacity
,
Rotation
,
Strain gages
,
Strain measurement
,
Wounds
Tennis Racket Shock Mitigation Experiments
J Biomech Eng. November 1995, 117(4): 479–484.
doi: https://doi.org/10.1115/1.2794211
Topics:
Shock (Mechanics)
,
Damping
,
String
,
Composite materials
,
Fast Fourier transforms
,
Free vibrations
,
Graphite
,
Metals
,
Wood products
An Analytical Model to Study Blunt Impact Response of the Rabbit P-F Joint
J Biomech Eng. November 1995, 117(4): 485–491.
doi: https://doi.org/10.1115/1.2794212
Topics:
Biological tissues
,
Bone
,
Cartilage
,
Damage
,
Elastic analysis
,
Elastic moduli
,
Materials properties
,
Plane strain
,
Poisson ratio
,
Shear stress
Technical Briefs
Reexamination of Steady Solutions of a Collapsible Channel Conveying Fluid
J Biomech Eng. November 1995, 117(4): 492–494.
doi: https://doi.org/10.1115/1.2794213
Topics:
Fluids
,
Tension
,
Equilibrium (Physics)
,
Fluid dynamics
,
Physiology
,
Shear (Mechanics)
,
Shear stress
,
Vessels
A Technique for Calibrating Measurements From Photographs of Sliced Specimens
J Biomech Eng. November 1995, 117(4): 495–497.
doi: https://doi.org/10.1115/1.2794214
Topics:
Calibration
,
Diffraction gratings
,
Engineering simulation
,
Geometry
,
Joint mechanics
,
Lenses (Optics)
,
Simulation
Email alerts
RSS Feeds
Evaluation of an Unloading Concept for Knee Osteoarthritis: A Pilot Study in a Small Patient Group
J Biomech Eng (January 2024)