Mechanical properties of human trabecular bone play an important role in age-related bone fragility and implant stability. Microfinite element (μFE) analysis allows computing the apparent elastic properties of trabecular bone for use in homogenized FE (hFE) analysis, but the results depend unfortunately on the type of applied boundary conditions (BCs). In this study, 167 human femoral trabecular cubic regions with a side length of 5.3 mm were extracted from three proximal femora and analyzed using μFE analysis to compare systematically their stiffness with kinematic uniform BCs (KUBCs) and periodicity-compatible mixed uniform BCs (PMUBCs). The obtained elastic constants were then used in the volume fraction and fabric-based orthotropic Zysset–Curnier model to identify their respective model parameters. As expected, PMUBCs lead to more compliant apparent elastic properties than KUBCs, especially in shear. The differences in stiffness decreased with bone volume fraction and mean intercept length (MIL). Unlike KUBCs, PMUBCs were sensitive to heterogeneity of the biopsies. The Zysset–Curnier model fitted the apparent elastic constants successfully in both cases with adjusted coefficients of determination () of 0.986 for KUBCs and 0.975 for PMUBCs. The proper use of these BCs for hFE analysis of whole bones will need to be investigated in future work.
Skip Nav Destination
Article navigation
January 2015
Research-Article
Comparison of Mixed and Kinematic Uniform Boundary Conditions in Homogenized Elasticity of Femoral Trabecular Bone Using Microfinite Element Analyses
Jarunan Panyasantisuk,
Jarunan Panyasantisuk
Institute for Surgical Technology
and Biomechanics,
Bern CH-3014,
e-mail: jarunan.panyasantisuk@istb.unibe.ch
and Biomechanics,
University of Bern
,Stauffacherstr. 78
,Bern CH-3014,
Switzerland
e-mail: jarunan.panyasantisuk@istb.unibe.ch
Search for other works by this author on:
Dieter H. Pahr,
Dieter H. Pahr
Institute for Lightweight Design
and Structural Biomechanics,
Vienna A-1040,
e-mail: pahr@ilsb.tuwien.ac.at
and Structural Biomechanics,
Vienna University of Technology
,Gusshausstr. 27-29/317
,Vienna A-1040,
Austria
e-mail: pahr@ilsb.tuwien.ac.at
Search for other works by this author on:
Thomas Gross,
Thomas Gross
Institute for Lightweight Design
and Structural Biomechanics,
Vienna A-1040,
e-mail: tgross@ilsb.tuwien.ac.at
and Structural Biomechanics,
Vienna University of Technology
,Gusshausstr. 27-29/317
,Vienna A-1040,
Austria
e-mail: tgross@ilsb.tuwien.ac.at
Search for other works by this author on:
Philippe K. Zysset
Philippe K. Zysset
Institute for Surgical Technology
and Biomechanics,
e-mail: philippe.zysset@istb.unibe.ch
and Biomechanics,
University of Bern
, Stauffacherstr. 78,Bern CH-3014
, Switzerland
e-mail: philippe.zysset@istb.unibe.ch
Search for other works by this author on:
Jarunan Panyasantisuk
Institute for Surgical Technology
and Biomechanics,
Bern CH-3014,
e-mail: jarunan.panyasantisuk@istb.unibe.ch
and Biomechanics,
University of Bern
,Stauffacherstr. 78
,Bern CH-3014,
Switzerland
e-mail: jarunan.panyasantisuk@istb.unibe.ch
Dieter H. Pahr
Institute for Lightweight Design
and Structural Biomechanics,
Vienna A-1040,
e-mail: pahr@ilsb.tuwien.ac.at
and Structural Biomechanics,
Vienna University of Technology
,Gusshausstr. 27-29/317
,Vienna A-1040,
Austria
e-mail: pahr@ilsb.tuwien.ac.at
Thomas Gross
Institute for Lightweight Design
and Structural Biomechanics,
Vienna A-1040,
e-mail: tgross@ilsb.tuwien.ac.at
and Structural Biomechanics,
Vienna University of Technology
,Gusshausstr. 27-29/317
,Vienna A-1040,
Austria
e-mail: tgross@ilsb.tuwien.ac.at
Philippe K. Zysset
Institute for Surgical Technology
and Biomechanics,
e-mail: philippe.zysset@istb.unibe.ch
and Biomechanics,
University of Bern
, Stauffacherstr. 78,Bern CH-3014
, Switzerland
e-mail: philippe.zysset@istb.unibe.ch
Manuscript received May 30, 2014; final manuscript received October 23, 2014; accepted manuscript posted November 3, 2014; published online December 10, 2014. Assoc. Editor: Blaine Christiansen.
J Biomech Eng. Jan 2015, 137(1): 011002
Published Online: January 1, 2015
Article history
Received:
May 30, 2014
Revision Received:
October 23, 2014
Accepted:
November 3, 2014
Online:
December 10, 2014
Citation
Panyasantisuk, J., Pahr, D. H., Gross, T., and Zysset, P. K. (January 1, 2015). "Comparison of Mixed and Kinematic Uniform Boundary Conditions in Homogenized Elasticity of Femoral Trabecular Bone Using Microfinite Element Analyses." ASME. J Biomech Eng. January 2015; 137(1): 011002. https://doi.org/10.1115/1.4028968
Download citation file:
Get Email Alerts
Effect of Internal Mechanical Environment of Porous Scaffolds on Mechano-driven Bone Ingrowth: A Numerical Study
J Biomech Eng (September 2023)
In Silico Mechanical Effort Analysis of the All-On-4 Design Performed With Platform-Switching Distal Short Dental Implants
J Biomech Eng (September 2023)
Related Articles
Elastic Anisotropy of Human Cortical Bone Secondary Osteons Measured by Nanoindentation
J Biomech Eng (February,2009)
Elastic Anisotropy of Trabecular Bone in the Elderly Human Vertebra
J Biomech Eng (November,2015)
Biophysical Analysis of Dystrophic and Osteogenic Models of Valvular Calcification
J Biomech Eng (February,2015)
Related Proceedings Papers
Related Chapters
Novel and Efficient Mathematical and Computational Methods for the Analysis and Architecting of Ultralight Cellular Materials and their Macrostructural Responses
Advances in Computers and Information in Engineering Research, Volume 2
Accuracy of an Axis
Mechanics of Accuracy in Engineering Design of Machines and Robots Volume I: Nominal Functioning and Geometric Accuracy
Infinitesimal Mechanics of the PKMs
Mechanics of Accuracy in Engineering Design of Machines and Robots Volume I: Nominal Functioning and Geometric Accuracy