An increase in anterior laxity following reconstruction of the anterior cruciate ligament (ACL) can result from lengthening of the graft construct either at the sites of fixation and/or between the sites of fixation (i.e., graft substance). Roentgen stereophotogrammetric analysis (RSA), which requires that radio-opaque markers be attached to the graft, has been shown to be a useful technique in determining lengthening in these regions. Previous methods have been used for attaching radio-opaque markers to the graft, but they all have limitations particularly for single-loop grafts. Therefore, the objective of this study was to evaluate injecting markers directly into the substance of a tendon as a viable method for measuring lengthening of single-loop graft constructs by determining the maximum amount of migration after cyclic loading. Tantalum spheres of 0.8 mm diameter were used as tendon markers. Ten single-loop tendon grafts were passed through tibial tunnels drilled in calf tibias and fixed with a tibial fixation device. Two tendon markers were inserted in one tendon bundle of each graft and the grafts were cyclically loaded for 225,000 cycles from 20 N to 170 N. At specified intervals, simultaneous radiographs were obtained of the tendon markers. Marker migration was computed as the change in distance between the two tendon markers parallel to the axis of the tibial tunnel. Marker migration had a root mean square (RMS) value of less than 0.1 mm. Because the RMS value indicates the error introduced into measurements of lengthening and because this error is negligible, the method described for attaching markers to single-loop ACL grafts has the potential to be useful for determining lengthening of single-loop ACL graft constructs in in vivo studies in humans.
Skip Nav Destination
e-mail: mlhull@ucdavis.edu
Article navigation
October 2005
Technical Briefs
Migration of Radio-Opaque Markers Injected Into Tendon Grafts: A Study Using Roentgen Stereophotogrammetric Analysis (RSA)
Conrad Kay Smith,
Conrad Kay Smith
Biomedical Engineering Program,
University of California
, Davis, CA 95616
Search for other works by this author on:
M. L. Hull,
M. L. Hull
530-752-6220
530-752-4158
Biomedical Engineering Program and Department of Mechanical Engineering,
e-mail: mlhull@ucdavis.edu
University of California
, Davis, CA 95616
Search for other works by this author on:
S. M. Howell
S. M. Howell
Department of Mechanical Engineering,
University of California
, Davis, CA 95616
Search for other works by this author on:
Conrad Kay Smith
Biomedical Engineering Program,
University of California
, Davis, CA 95616
M. L. Hull
530-752-6220
530-752-4158
Biomedical Engineering Program and Department of Mechanical Engineering,
University of California
, Davis, CA 95616e-mail: mlhull@ucdavis.edu
S. M. Howell
Department of Mechanical Engineering,
University of California
, Davis, CA 95616J Biomech Eng. Oct 2005, 127(5): 887-890 (4 pages)
Published Online: May 17, 2005
Article history
Received:
September 28, 2004
Revised:
May 17, 2005
Citation
Smith, C. K., Hull, M. L., and Howell, S. M. (May 17, 2005). "Migration of Radio-Opaque Markers Injected Into Tendon Grafts: A Study Using Roentgen Stereophotogrammetric Analysis (RSA)." ASME. J Biomech Eng. October 2005; 127(5): 887–890. https://doi.org/10.1115/1.1992533
Download citation file:
Get Email Alerts
Simulating the Growth of TATA-Box Binding Protein-Associated Factor 15 Inclusions in Neuron Soma
J Biomech Eng (December 2024)
Related Articles
How Cyclic Loading Affects the Migration of Radio-Opaque Markers Attached to Tendon Grafts Using a New Method: A Study Using Roentgen Stereophotogrammetric Analysis (RSA)
J Biomech Eng (February,2004)
Lengthening of a Single-Loop Tibialis Tendon Graft Construct After Cyclic Loading: A Study Using Roentgen Stereophotogrammetric Analysis
J Biomech Eng (June,2006)
Related Proceedings Papers
Related Chapters
Properties of Tantalum for Applications in the Chemical Process Industry
Refractory Metals and Their Industrial Applications
Correlation of Hardening and Microstructure of Tantalum Irradiated with Heavy Ions
Effects of Radiation on Materials: 19th International Symposium
Tantalum and Niobium in Some Electronic Applications
Refractory Metals and Their Industrial Applications