Background. Computational fluid dynamics (CFD) simulations are used to analyze the wall shear stress distribution and flow streamlines near the throat of a stented basilar side-wall aneurysm. Previous studies of stented aneurysm flows used low mesh resolution, did not include mesh convergence analyses, and depended upon conformal meshing techniques that apply only to very artificial stent geometries. Method of Approach. We utilize general-purpose computer assisted design and unstructured mesh generation tools that apply in principle to stents and vasculature of arbitrary complexity. A mesh convergence analysis for stented steady flow is performed, varying node spacing near the stent. Physiologically realistic pulsatile simulations are then performed using the converged mesh. Results. Artifact-free resolution of the wall shear stress field on stent wires requires a node spacing of approximately 1/3 wire radius. Large-scale flow features tied to the velocity field are, however, captured at coarser resolution (nodes spaced by about one wire radius or more). Conclusions. Results are consistent with previous work, but our methods yield more detailed insights into the complex flow dynamics. However, routine applications of CFD to anatomically realistic cases still depend upon further development of dedicated algorithms, most crucially to handle geometry definition and mesh generation for complicated stent deployments.
Skip Nav Destination
e-mail: steinman@imaging.robarts.ca
Article navigation
June 2004
Technical Briefs
Finite-Element Modeling of the Hemodynamics of Stented Aneurysms
Gordan R. Stuhne and,
Gordan R. Stuhne and
Imaging Research Labs, Robarts Research Institute, 100 Perth Dr., P.O. Box 5015, London, Ontario, Canada N6A 5K8
Department of Medical Biophysics, University of Western Ontario, Medical Sciences Building, London, Canada N6A 5C1, Phone: (519) 663-5777 ext. 34113, Fax: (519) 663-3078
Search for other works by this author on:
David A. Steinman
e-mail: steinman@imaging.robarts.ca
David A. Steinman
Imaging Research Labs, Robarts Research Institute, 100 Perth Dr., P.O. Box 5015, London, Ontario, Canada N6A 5K8
Department of Medical Biophysics, University of Western Ontario, Medical Sciences Building, London, Canada N6A 5C1, Phone: (519) 663-5777 ext. 34113, Fax: (519) 663-3078
Search for other works by this author on:
Gordan R. Stuhne and
Imaging Research Labs, Robarts Research Institute, 100 Perth Dr., P.O. Box 5015, London, Ontario, Canada N6A 5K8
Department of Medical Biophysics, University of Western Ontario, Medical Sciences Building, London, Canada N6A 5C1, Phone: (519) 663-5777 ext. 34113, Fax: (519) 663-3078
David A. Steinman
Imaging Research Labs, Robarts Research Institute, 100 Perth Dr., P.O. Box 5015, London, Ontario, Canada N6A 5K8
Department of Medical Biophysics, University of Western Ontario, Medical Sciences Building, London, Canada N6A 5C1, Phone: (519) 663-5777 ext. 34113, Fax: (519) 663-3078
e-mail: steinman@imaging.robarts.ca
Contributed by the Bioengineering Division for publication in the JOURNAL OF BIOMECHANICAL ENGINEERING. Manuscript received by the Bioengineering Division July 29, 2003; revision received October 10, 2003. Associate Editor: J. D. Humphrey.
J Biomech Eng. Jun 2004, 126(3): 382-387 (6 pages)
Published Online: June 24, 2004
Article history
Received:
July 29, 2003
Revised:
October 10, 2003
Online:
June 24, 2004
Citation
Stuhne and , G. R., and Steinman, D. A. (June 24, 2004). "Finite-Element Modeling of the Hemodynamics of Stented Aneurysms ." ASME. J Biomech Eng. June 2004; 126(3): 382–387. https://doi.org/10.1115/1.1762900
Download citation file:
Get Email Alerts
Simulating the Growth of TATA-Box Binding Protein-Associated Factor 15 Inclusions in Neuron Soma
J Biomech Eng (December 2024)
Evaluation of an Inverse Method for Quantifying Spatially Variable Mechanics
J Biomech Eng (December 2024)
Effect of Structure and Wearing Modes on the Protective Performance of Industrial Safety Helmet
J Biomech Eng (December 2024)
Sex-Based Differences and Asymmetry in Hip Kinematics During Unilateral Extension From Deep Hip Flexion
J Biomech Eng (December 2024)
Related Articles
Numerical Study of Shear-Induced Thrombus Formation Over Aterial Stent Struts
J. Med. Devices (June,2009)
Evaluating Design of Abdominal Aortic Aneurysm Endografts in a Patient-Specific Model Using Computational Fluid Dynamics
J. Med. Devices (June,2011)
Influence of the Anatomical Structure on the Hemodynamics of Iliac Vein Stenosis
J Biomech Eng (January,2023)
CFD and PTV Steady Flow Investigation in an Anatomically Accurate Abdominal Aortic Aneurysm
J Biomech Eng (January,2009)
Related Proceedings Papers
Related Chapters
CFD Simulations of a Mixed-flow Pump Using Various Turbulence Models
Mixed-flow Pumps: Modeling, Simulation, and Measurements
Mesh Generation
Introduction to Finite Element, Boundary Element, and Meshless Methods: With Applications to Heat Transfer and Fluid Flow
Subsection NB—Class 1 Components
Companion Guide to the ASME Boiler & Pressure Vessel Code, Volume 1, Second Edition