Background. Computational fluid dynamics (CFD) simulations are used to analyze the wall shear stress distribution and flow streamlines near the throat of a stented basilar side-wall aneurysm. Previous studies of stented aneurysm flows used low mesh resolution, did not include mesh convergence analyses, and depended upon conformal meshing techniques that apply only to very artificial stent geometries. Method of Approach. We utilize general-purpose computer assisted design and unstructured mesh generation tools that apply in principle to stents and vasculature of arbitrary complexity. A mesh convergence analysis for stented steady flow is performed, varying node spacing near the stent. Physiologically realistic pulsatile simulations are then performed using the converged mesh. Results. Artifact-free resolution of the wall shear stress field on stent wires requires a node spacing of approximately 1/3 wire radius. Large-scale flow features tied to the velocity field are, however, captured at coarser resolution (nodes spaced by about one wire radius or more). Conclusions. Results are consistent with previous work, but our methods yield more detailed insights into the complex flow dynamics. However, routine applications of CFD to anatomically realistic cases still depend upon further development of dedicated algorithms, most crucially to handle geometry definition and mesh generation for complicated stent deployments.

1.
Wardlaw
,
J. M.
, and
White
,
P. M.
,
2000
, “
The detection and management of unruptured intracranial aneurysms
,”
Brain
,
123
, pp.
205
221
.
2.
Aenis
,
M.
,
Stancampiano
,
A. P.
,
Wakhloo
,
A. K.
, and
Lieber
,
B. B.
,
1997
, “
Modeling of flow in a straight stented and nonstented side wall aneurysm model
,”
J. Biomech. Eng.
,
119
, pp.
206
212
.
3.
Lieber
,
B. B.
,
Stancampiano
,
A. P.
, and
Wakhloo
,
A. K.
,
1997
, “
Alteration of hemodynamics in aneurysm models by stenting: influence of stent porosity
,”
Ann. Biomed. Eng.
,
25
, pp.
460
469
.
4.
Imbesi
,
S. G.
, and
Kerber
,
C. W.
,
2001
, “
Analysis of slipstream flow in a wide-necked basilar artery aneurysm: evaluation of potential treatment regimens
,”
AJNR Am. J. Neuroradiol.
,
22
, pp.
721
724
.
5.
Lieber
,
B. B.
, and
Gounis
,
M. J.
,
2002
, “
The physics of endoluminal stenting in the treatment of cerebrovascular aneurysms
,”
Neurol. Res.
,
24
, Suppl 1, pp.
33
42
.
6.
LaDisa
, Jr.,
J. F.
,
Guler
,
I.
,
Olson
,
L. E.
,
Hettrick
,
D. A.
,
Kersten
,
J. R.
,
Warltier
,
D. C.
, and
Pagel
,
P. S.
,
2003
, “
Three-dimensional computational fluid dynamics modeling of alterations in coronary wall shear stress produced by stent implantation
,”
Ann. Biomed. Eng.
,
31
, pp.
972
980
.
7.
Groden
,
C.
,
Laudan
,
J.
,
Gatchell
,
S.
, and
Zeumer
,
H.
,
2001
, “
Three-dimensional pulsatile flow simulation before and after endovascular coil embolization of a terminal cerebral aneurysm
,”
J. Cereb. Blood Flow Metab.
,
21
, pp.
1464
71
.
8.
C. R. Ethier, D. A. Steinman, and M. Ojha, “Comparisons between computational hemodynamics, photochromic dye flow visualization and magnetic resonance velocimetry,” in The haemodynamics of arterial organs—comparison of computational predictions with in vivo and in vitro data, M. W. Collins, Ed. Southampton: WIT Press, 1999, pp. 131–183.
9.
Ethier
,
C. R.
,
Prakash
,
S.
,
Steinman
,
D. A.
,
Leask
,
R. L.
,
Couch
,
G. G.
, and
Ojha
,
M.
,
2000
, “
Steady flow separation patterns in a 45° junction
,”
J. Fluid Mech.
,
411
, pp.
1
38
.
10.
Maday
,
Y.
,
Patera
,
A. T.
, and
Ronquist
,
E. M.
,
1990
, “
An operator-integration-factor splitting method for time-dependent problems: Application to incompressible fluid flow
,”
J. Sci. Comput.
5
, pp.
263
292
.
11.
Prakash
,
S.
, and
Ethier
,
C. R.
,
2001
, “
Requirements for mesh resolution in 3D computational hemodynamics
,”
ASME J. Biomech. Eng.
,
123
, pp.
134
144
.
12.
Stuhne, G., and Steinman, D. A., “Mesh resolution requirements for the numerical simulation of flow through stented aneurysms,” Proc. ASME Bioengineering Conference, Key Biscayne FL, 2003.
13.
Ma
,
D.
,
Lin
,
F.
, and
Chua
,
C. K.
,
2001
, “
Rapid prototyping applications in medicine. Part 1: NURBS-based volume modeling
,”
Int. J. Adv. Manuf. Technol.
,
18
, pp.
103
117
.