Thermo-mechanical equations were developed from machining theory to predict heat generation due to drilling and were coupled with a heat transfer FEM simulation to predict the temperature rise and thermal injury in bone during a drilling operation. The rotational speed, feed rate, drill geometry and bone material properties were varied in a parametric analysis to determine the importance of each on temperature rise and therefore on thermal damage. It was found that drill speed, feed rate and drill diameter had the most significant thermal impact while changes in drill helix angle, point angle and bone thermal properties had relatively little effect.

1.
Eriksson
,
A. R.
, and
Albrektsson
,
T.
,
1983
, “
Temperature Threshold Levels for Heat-Induced Bone Tissue Injury: A Vital-Microscopic Study in the Rabbit
,”
J. Prosthet. Dent.
,
50
(
1
), pp.
101
107
.
2.
Lundskog, J., 1972, “Heat and Bone Tissue,” Scand. J. Plast. Reconstr Surg., Supplementum 9, pp. 1–80.
3.
Boyne
,
P. J.
,
1966
, “
Histologic Response of Bone to Sectioning by High-Speed Rotary Instruments
,”
J. Dent. Res.
,
45
(
2
), pp.
270
276
.
4.
Costich
,
E. R.
,
Youngblood
,
P. J.
, and
Walden
,
J. M.
,
1964
, “
A Study of the Effects of High-Speed Rotary Instruments on Bone Repair in Dogs
,”
Oral Surg., Oral Med., Oral Pathol.
,
17
(
5
), pp.
563
571
.
5.
Moss
,
R. W.
,
1964
, “
Histopathologic Reaction of Bone to Surgical Cutting
,”
Oral Surg., Oral Med., Oral Pathol.
,
17
(
3
), pp.
405
414
.
6.
Kramer
,
I. R. H.
,
1960
, “
Changes in Dentine During Cavity Preparation Using Turbine Handpieces
,”
Br. Dent. J.
,
109
, pp.
59
64
.
7.
Spatz
,
S.
,
1965
, “
Early Reaction in Bone Following the Use of Burs Rotating at Conventional and Ultra Speeds
,”
Oral Surg., Oral Med., Oral Pathol.
,
19
(
6
), pp.
808
816
.
8.
Thompson
,
H. C.
,
1958
, “
Effect of Drilling into Bone
,”
J. Oral Surgery
,
16
, pp.
22
30
.
9.
Pallan
,
F. G.
,
1960
, “
Histological Changes in Bone after Insertion of Skeletal Fixation Pins
,”
J. Oral Surg., Anesth. Hosp. Dent. Serv.
,
18
, pp.
400
408
.
10.
Matthews
,
L. S.
, and
Hirsch
,
C.
,
1972
, “
Temperatures Measured in Human Cortical Bone when Drilling
,”
J. Bone Jt. Surg.
,
54-A
(
2
), pp.
297
308
.
11.
Vaughn
,
R. C.
, and
Peyton
,
F. A.
,
1951
, “
The Influence of Rotational Speed on Temperature Rise During Cavity Preparation
,”
J. Dent. Res.
,
30
(
5
), pp.
737
744
.
12.
Sorenson
,
F. M.
,
Cantwell
,
K. R.
, and
Aplin
,
A. W.
,
1964
, “
Thermogenics in Cavity Preparation Using Air Turbine Handpieces: The Relationship of Heat Transferred to Rate of Tooth Structure Removal
,”
J. Prosthet. Dent.
,
14
(
3
), pp.
524
532
.
13.
Abouzgia
,
M. B.
, and
James
,
D. F.
,
1997
, “
Temperature Rise During Drilling through Bone
,”
Int. J. Oral Maxillofac Implants
,
12
(
3
), pp.
342
353
.
14.
Tay
,
A. O.
,
Stevenson
,
M. G.
,
Davis
,
G. d. V.
, and
Oxley
,
P. L. B.
,
1976
, “
A Numerical Method for Calculating Temperature Distributions in Machining, from Force and Shear Angle Measurements
,”
Int. J. Mach. Tool Des. Res.
,
16
, pp.
335
349
.
15.
Jacobs
,
C. H.
,
Berry
,
J. T.
,
Pope
,
M. H.
, and
Hoaglund
,
F. T.
,
1976
, “
A Study of the Bone Machining Process—Drilling
,”
J. Biomech.
,
9
, pp.
343
349
.
16.
Wiggins
,
K. L.
, and
Malkin
,
S.
,
1976
, “
Drilling of Bone
,”
J. Biomech.
,
9
, pp.
553
559
.
17.
Jacobs
,
C. H.
,
Pope
,
M. H.
,
Berry
,
J. T.
, and
Hoaglund
,
F.
,
1974
, “
A Study of the Bone Machining Process—Orthogonal Cutting
,”
J. Biomech.
,
7
, pp.
131
136
.
18.
Krause
,
W. R.
,
1987
, “
Orthogonal Bone Cutting: Saw Design and Operating Characteristics
,”
J. Biomech. Eng.
,
109
, pp.
263
271
.
19.
Merchant
,
M. E.
,
1945
, “
Mechanics of the Metal Cutting Process
,”
J. Appl. Phys.
,
16
, pp.
267
324
.
20.
Boothroyd
,
G.
,
1963
, “
Temperatures in Orthogonal Metal Cutting
,”
Proceedings of the Institution of Mechanical Engineers
,
177
(
29
), pp.
789
802
.
21.
Bhattacharyya, A., and Ham, I., Design of Cutting Tools-Use of Metal Cutting Theory. 1969, ASTME Publication.
22.
Sedlin, E. D., 1965, “A Rheologic Model for Cortical Bone,” Acta Orthop. Scand., Supplementum 83, pp. 1–77.
23.
Carter
,
D. R.
, and
Hayes
,
W. C.
,
1976
, “
Bone Compressive Strength: The Influence of Density and Strain Rate
,”
Science
,
194
, pp.
1174
1175
.
24.
Carter
,
D. R.
, and
Caler
,
W. E.
,
1983
, “
Cycle Dependent and Time Dependent Bone Fracture with Repeated Loading
,”
J. Biomech. Eng.
,
105
, pp.
166
170
.
25.
Saha
,
S.
,
1977
, “
Longitudinal Shear Properties of Human Compact Bone and its Constituents, and the Associated Failure Mechanisms
,”
J. Mater. Sci.
,
12
, pp.
1798
1806
.
26.
Saha
,
S.
,
Pal
,
S.
, and
Albright
,
J. A.
,
1982
, “
Surgical Drilling: Design and Performance of an Improved Drill
,”
J. Biomech. Eng.
,
104
, pp.
245
252
.
27.
Abouzgia, M. B., 1995, “Bone Temperature Rise During Drilling,” Ph.D. Thesis, University of Toronto, Toronto, Canada.
28.
Davidson
,
S. R. H.
, and
James
,
D. F.
,
2000
, “
Measurement of Thermal Conductivity of Bovine Cortical Bone
,”
Med. Eng. Phys.
,
22
, pp.
741
747
.
29.
Henriques
,
F. C.
,
1947
, “
Studies of Thermal Injury V. The Predictability and the Significance of Thermally Induced Rate Processes Leading to Irreversible Epidermal Injury
,”
Arch. Pathol.
,
43
, pp.
489
502
.
30.
Moritz
,
A. R.
, and
Henriques
,
F. C.
,
1947
, “
Studies of Thermal Injury II. The Relative Importance of Time and Surface Temperature in the Causation of Cutaneous Burns
,”
Am. J. Pathol.
,
23
, pp.
695
720
.
31.
Rafel
,
S. S.
,
1962
, “
Temperature Changes During High-Speed Drilling on Bone
,”
J. Oral Surg., Anesth. Hosp. Dent. Serv.
,
20
, pp.
475
477
.
32.
Abouzgia
,
M. B.
, and
James
,
D. F.
,
1995
, “
Measurements of Shaft Speed While Drilling through Bone
,”
J. Oral Maxillofac. Surg.
,
53
, pp.
1308
1315
.
33.
Farnworth, G. H., and Burton, J. A., 1974, “Optimization of Drill Geometry for Orthopaedic Surgery,” in Proceedings of the 14th International Machine Tool Design and Research Conference, pp. 227–233.
34.
Huiskes, R., 1980, “Some Fundamental Aspects of Human Joint Replacement,” Acta Orthop. Scand., Supplementum 185, pp. 44–108.
35.
Krause
,
W. R.
,
Bradbury
,
D. W.
,
Kelly
,
J. E.
, and
Lunceford
,
E. M.
,
1982
, “
Temperature Elevations in Orthopaedic Cutting Operations
,”
J. Biomech.
,
15
(
4
), pp.
267
275
.
36.
Pope
,
M. H.
, and
Outwater
,
J. O.
,
1972
, “
The Fracture Characteristics of Bone Substance
,”
J. Biomech.
,
5
, pp.
457
465
.
37.
Piekarski
,
K.
,
1970
, “
Fracture of Bone
,”
J. Appl. Phys.
,
41
(
1
), pp.
215
223
.
You do not currently have access to this content.