The biomechanical properties of human ankle-subtalar joints have been determined in a quasi-static loading condition. The moving center of rotation was determined and approximated by a fixed point. The moment-angle characteristics of the ankle-subtalar joints about the fixed center of rotation have been measured under four basic movements: dorsiflexion, plantarflexion, inversion, and eversion. The method linearly increases rotation of the calcaneus until failure, and measures the moments, forces, and linear and rotational displacements. Failure was identified as the initial drop of moment on plot showing the moment representing gross injury or microfilament damage. In this study, 32 human ankle-subtalar joints have been tested to failure. The center of rotation of the ankle-subtalar joints was determined for a pure dorsiflexion (9 specimens), plantarflexion (7 specimens), inversion (8 specimens), and eversion (8 specimens), Failure in the joints occurred at an average moment of −33.1 ± 16.5 Nm in dorsiflexion, 40.1 ± 9.2 Nm in plantarflexion, −34.1 ± 14.5 Nm in inversion, and 48.1 ± 12.2 Nm in eversion. The failure angle was also determined in all four motions. Failure was best predicted by an angle of −44.0 ± 10.9 deg in dorsiflexion, 71.6 ± 5.7 deg in plantarflexion, −34.3 ± 7.5 deg in inversion, and 32.4 ± 7.3 deg in eversion. Injury was identified in every preparation tested in inversion and eversion, while it resulted in five of the nine preparations in dorsiflexion, and in three of the seven in plantarflexion. Injury occurred at −47.0 ± 5.3 deg and −36.2 ± 14.8 Nm in dorsiflexion, and at 68.7 ± 5.9 deg and 36.7 ± 2.5 Nm in plantarflexion. The results obtained in this study provide basic information of the ankle-subtalar joint kinematics, biomechanics, and injury. The data will be used to form a basis for corridors of the ankle-subtalar joint responses.
Skip Nav Destination
e-mail: chantal@ip.chalmers.se
Article navigation
February 1998
Research Papers
Biomechanical Properties of Human Cadaveric Ankle-Subtalar Joints in Quasi-Static Loading
C. S. Parenteau,
C. S. Parenteau
Department of Injury Prevention, Chalmers University of Technology, 412 96 Gothenberg, Sweden
e-mail: chantal@ip.chalmers.se
Search for other works by this author on:
D. C. Viano,
D. C. Viano
Department of Injury Prevention, Chalmers University of Technology, 412 96 Gothenberg, Sweden; Research & Development Center, General Motors Corporation, Warren, MI 48090-9055
Search for other works by this author on:
P. Y. Petit
P. Y. Petit
Ecole Nationale Supe´rieure d’Arts et Me´tiers, 151 Boulevard de I’Hoˆpital, 75013 Paris, France
Search for other works by this author on:
C. S. Parenteau
Department of Injury Prevention, Chalmers University of Technology, 412 96 Gothenberg, Sweden
e-mail: chantal@ip.chalmers.se
D. C. Viano
Department of Injury Prevention, Chalmers University of Technology, 412 96 Gothenberg, Sweden; Research & Development Center, General Motors Corporation, Warren, MI 48090-9055
P. Y. Petit
Ecole Nationale Supe´rieure d’Arts et Me´tiers, 151 Boulevard de I’Hoˆpital, 75013 Paris, France
J Biomech Eng. Feb 1998, 120(1): 105-111 (7 pages)
Published Online: February 1, 1998
Article history
Received:
March 26, 1996
Revised:
January 9, 1997
Online:
January 7, 2008
Citation
Parenteau, C. S., Viano, D. C., and Petit, P. Y. (February 1, 1998). "Biomechanical Properties of Human Cadaveric Ankle-Subtalar Joints in Quasi-Static Loading." ASME. J Biomech Eng. February 1998; 120(1): 105–111. https://doi.org/10.1115/1.2834289
Download citation file:
Get Email Alerts
A Numerical Study of Crack Penetration and Deflection at the Interface Between Peritubular and Intertubular Dentin
J Biomech Eng (December 2024)
Related Articles
Repeatability of a Dislocation Spinal Cord Injury Model in a Rat—A High-Speed Biomechanical Analysis
J Biomech Eng (October,2017)
A Technique for Quantifying Wrist Motion Using Four-Dimensional Computed Tomography: Approach and Validation
J Biomech Eng (July,2015)
Rotational Stiffness of American Football Shoes Affects Ankle Biomechanics and Injury Severity
J Biomech Eng (June,2015)
A Biomechanical Evaluation of Whiplash Using a Multi-Body Dynamic Model
J Biomech Eng (April,2003)
Related Proceedings Papers
Related Chapters
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices
Datum Targets
Geometric Dimensioning and Tolerancing Handbook: Applications, Analysis & Measurement
Datum Targets
Geometric Dimensioning and Tolerancing: Applications, Analysis, Gauging and Measurement [per ASME Y14.5-2018]