Recent studies suggest that hip padding systems reduce the incidence of hip fractures during falls. However, no data exist on the force attenuating capacity of hip pads under realistic fall impact conditions, and thus it is difficult to compare the protective merit of various pad designs. Our goal is to design a comfortable hip padding system which reduces femoral impact force in a fall below the mean force required to fracture the elderly cadaveric femur. In pursuit of this objective, we designed and constructed a hip pad testing system consisting of an impact pendulum and surrogate human pelvis. We then developed a hip pad containing a shear-thickening material which allows for shunting of the impact energy away from the femur and into the surrounding soft tissue. Finally, we conducted experiments to assess whether the surrogate pelvis accurately represents the impact behavior of the human female pelvis in a fall, and to determine whether our energy-shunting pad attenuates femoral impact force in a fall more effectively than seven available padding systems. We found the surrogate pelvis accurately represented the human female pelvis in regional variation in soft tissue stiffness, total effective stiffness and damping, and impact force attenuation provided by trochanteric soft tissues. We also found that our padding system attenuated femoral impact force by 65 percent, thereby providing two times the force attenuation of the next best system. Moreover, the energy-shunting pad was the only system capable of lowering femoral impact force well below the mean force required to fracture the elderly femur in a fall loading configuration. These results suggest that the force attenuating potential of hip pads which focus on shunting energy away from the femur is superior to those which rely on absorbing energy in the pad material. While these in-vitro results are encouraging, carefully designed prospective clinical trials will be necessary to determine the efficacy of these approaches to hip fracture prevention.

1.
Barnes
H. A.
, “
Shear thickening (“dilatancy”) in suspensions of non-aggregating solid particles dispersed in Newtonian liquids
.”
J Rheology
,
33
:
329
366
,
1989
.
2.
Courtney
A. C.
,
Wachtel
E. F.
,
Myers
E. R.
, and
Hayes
W. C.
, “
Effects of loading rate on strength of the proximal femur
,”
Calcif Tissue Int
,
55
:
53
58
,
1994
.
3.
Ferber, R. C., “Protective Garment for the Hip Area,” United States Patent No. 4807301, 1989.
4.
Greenspan
S. L.
,
Myers
E. R.
,
Maitland
L. A.
,
Resnick
N. M.
, and
Hayes
W. C.
, “
Fall Severity and Bone Mineral Density as Risk Factors for Hip Fracture in Ambulatory Elderly
,”
JAMA
,
271
:
128
133
,
1994
.
5.
Hayes, W. C., Robinovitch, S. N., and McMahon, T. A., “Bone fracture prevention garment and method,” U.S. Patent Office, Serial No. 979154, 1992.
6.
Kelsey
J. L.
, and
Hoffman
S.
, “
Risk Factors for Hip Fracture
,”
N. Engl. J. Med.
,
316
:
404
406
,
1987
.
7.
Lauritzen
J. B.
, and
Lund
B.
, “
Impacts and padding of the hip in relation to hip fractures
,”
Trans 37th ORS
,
16
:
140
140
,
1991
.
8.
Lauritzen
J. B.
,
Petersen
M. M.
, and
Lund
B.
, “
Effect of external hip protectors on hip fractures.
Lancet
,
341
:
11
13
,
1993
.
9.
Lotz
J. C.
, and
Hayes
W. C.
, “
Estimates of hip fracture risk from falls using quantitative computed tomography
,”
J Bone Joint Surg [Am]
,
72
:
689
700
,
1990
.
10.
Melton, L. J. III, “Epidemiology of fractures,” Osteoporosis: Etiology, Diagnosis, and Management, Raven Press, New York, pp. 133–154, 1988.
11.
National Hospital Discharge Survey 1985 Summary, PHS 86-1250, National Center for Health Statistics, Hyattsville, MD, 1986.
12.
Robinovitch
S. N.
,
Hayes
W. C.
, and
McMahon
T. A.
, “
Prediction of femoral impact forces in falls on the hip
,”
ASME JOURNAL OF BIOMECHANICAL ENGINEERING
,
113
:
366
374
,
1991
.
13.
Sellberg
M. S.
,
Huston
J. C.
, and
Kruger
D. H.
, “
The development of a passive protective device for the elderly to prevent hip fractures from accidental falls
,”
Advances in Bioengineering
, ASME, BED
22
:
505
508
,
1992
.
14.
Strock, A. E., “Protective Appliance for the Hip Joint Area,” United States Patent No. 4926883, 1987.
15.
van den Kroonenberg
A.
,
Munih
P.
,
Weigent-Hayes
M.
,
McMahon
T. A.
, “
Hip impact velocities and body configurations for experimental falls from standing height
,”
Trans 39th ORS
,
18
:
24
24
,
1993
.
16.
Weber
T. G.
,
Yang
K. H.
,
Woo
R.
, and
Fitzgerald
R. H.
, “
Proximal femur strength: Correlations of the rate of loading and bone mineral density
,”
Advances in Bioengineering
, ASME, BED
22
:
111
114
,
1992
.
17.
Wortberg, W. E., Z Gerontol, 24:169–173, 1988 (in German).
This content is only available via PDF.