A thermal method has been developed to quantify continuous perfusion changes with self-calibration. A dynamic, one-dimensional bio-heat transfer model of the thermal probe and tissue describes the system response to either continuous or transient heating. A nonlinear least-squares fit of the model to experimental data yields estimates of the baseline perfusion and other model parameters. With a partial analytical solution of the model, the optimal estimation procedure is two orders of magnitude more efficient than with a total numerical solution of the model system. Experimental data is used to estimate the operating relations between perfusion and the temperature measurement. A new procedure has also been presented to obtain the dynamic response of the system for continuous measurement of perfusion.
Skip Nav Destination
Article navigation
February 1995
Technical Papers
Estimation of Cerebral Blood Flow From Thermal Measurement
Datong Wei,
Datong Wei
Department of Neurosciences, The Cleveland Clinic Foundation, Cleveland, OH 44195-5283 and Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH
Search for other works by this author on:
G. M. Saidel,
G. M. Saidel
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH
Search for other works by this author on:
S. C. Jones
S. C. Jones
Cerebrovascular Research Laboratory, The Cleveland Clinic Research Institute, 9500 Euclid Ave., Cleveland, OH 44195-5283
Search for other works by this author on:
Datong Wei
Department of Neurosciences, The Cleveland Clinic Foundation, Cleveland, OH 44195-5283 and Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH
G. M. Saidel
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH
S. C. Jones
Cerebrovascular Research Laboratory, The Cleveland Clinic Research Institute, 9500 Euclid Ave., Cleveland, OH 44195-5283
J Biomech Eng. Feb 1995, 117(1): 74-85 (12 pages)
Published Online: February 1, 1995
Article history
Received:
January 24, 1993
Revised:
February 15, 1994
Online:
October 30, 2007
Citation
Wei, D., Saidel, G. M., and Jones, S. C. (February 1, 1995). "Estimation of Cerebral Blood Flow From Thermal Measurement." ASME. J Biomech Eng. February 1995; 117(1): 74–85. https://doi.org/10.1115/1.2792273
Download citation file:
Get Email Alerts
Cited By
Related Articles
Calibration Tools for Scanning Thermal Microscopy Probes Used in Temperature Measurement Mode
J. Heat Transfer (July,2019)
Lagging Behavior in Biological Systems
J. Heat Transfer (May,2012)
Theory on Thermal Probe Arrays for the Distinction Between the Convective and the Perfusive Modalities of Heat Transfer in Living Tissues
J Biomech Eng (November,1987)
Cryosurgery of Normal and Tumor Tissue in the Dorsal Skin Flap Chamber: Part I—Thermal Response
J Biomech Eng (August,2001)
Related Proceedings Papers
Related Chapters
EVALUATION OF THERMAL PROBE COOLING EFFECT BASED ON PIPELINE PARALLEL OPTICAL CABLE
Pipeline Integrity Management Under Geohazard Conditions (PIMG)
Introduction and Scope
High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging
Principles
Ultrasonic Methods for Measurement of Small Motion and Deformation of Biological Tissues for Assessment of Viscoelasticity