Cervical spine injuries such as wedge, burst, and tear drop fractures are often associated with compressive axial loads delivered to the human head-neck complex. Understanding the injury mechanisms, the kinematics of the anatomic structure, and the tissue tolerances can improve clinical prognosis and facilitate a better design for anthropomorphic devices. The axial compressive response of human cadaveric preparations was compared with the 50th percentile anthropomorphic Hybrid III manikin under various loading rates. Ten fresh human cadavers were used in the study. Intact cadaver torsos, head-cervical spines, and ligamentous cervical columns were tested. The head-neck structure and the neck (without head) of the Hybrid III manikin were also tested. Responses of the human cadaveric preparations and manikin structures were nonlinear at all rates of loading. However, axial stiffness, a measure of the ability of the structure to withstand external force, was higher under all rates of loading for manikin preparations when compared with the human cadaveric tissues.
Skip Nav Destination
Article navigation
August 1989
Research Papers
Biomechanical Evaluation of the Axial Compressive Responses of the Human Cadaveric and Manikin Necks
N. Yoganandan,
N. Yoganandan
Department of Neurosurgery, The Medical College of Wisconsin, Veterans Administration Medical Center, Marquette University, Milwaukee, WI
Search for other works by this author on:
A. Sances, Jr.,
A. Sances, Jr.
Department of Neurosurgery, The Medical College of Wisconsin, Veterans Administration Medical Center, Marquette University, Milwaukee, WI
Search for other works by this author on:
F. Pintar
F. Pintar
Department of Neurosurgery, The Medical College of Wisconsin, Veterans Administration Medical Center, Marquette University, Milwaukee, WI
Search for other works by this author on:
N. Yoganandan
Department of Neurosurgery, The Medical College of Wisconsin, Veterans Administration Medical Center, Marquette University, Milwaukee, WI
A. Sances, Jr.
Department of Neurosurgery, The Medical College of Wisconsin, Veterans Administration Medical Center, Marquette University, Milwaukee, WI
F. Pintar
Department of Neurosurgery, The Medical College of Wisconsin, Veterans Administration Medical Center, Marquette University, Milwaukee, WI
J Biomech Eng. Aug 1989, 111(3): 250-255 (6 pages)
Published Online: August 1, 1989
Article history
Received:
February 10, 1988
Revised:
April 4, 1989
Online:
June 12, 2009
Citation
Yoganandan, N., Sances, A., Jr., and Pintar, F. (August 1, 1989). "Biomechanical Evaluation of the Axial Compressive Responses of the Human Cadaveric and Manikin Necks." ASME. J Biomech Eng. August 1989; 111(3): 250–255. https://doi.org/10.1115/1.3168374
Download citation file:
Get Email Alerts
Cited By
Effect of Collagen Fiber Tortuosity Distribution on the Mechanical Response of Arterial Tissues
J Biomech Eng (February 2025)
Related Articles
Biomechanical Behaviors in Three Types of Spinal Cord Injury Mechanisms
J Biomech Eng (August,2016)
Comparison of Hybrid-III and Postmortem Human Surrogate Response to Simulated Underbody Blast Loading
J Biomech Eng (May,2015)
A Biomechanical Evaluation of Whiplash Using a Multi-Body Dynamic Model
J Biomech Eng (April,2003)
Related Proceedings Papers
Related Chapters
Simple Structural Elements
Introduction to Plastics Engineering
Introduction and Definitions
Handbook on Stiffness & Damping in Mechanical Design
Radial Delayed Hydride Cracking in Irradiated Zircaloy-2 Cladding: Advanced Characterization Techniques
Zirconium in the Nuclear Industry: 20th International Symposium