We measured the Fahraeus effect of blood flowing in a sheet flow model formed with two glass slides. The number of red blood cells in the sheet flow was counted to determine a sheet hematocrit Hs and the discharge hemotocrit Hd was measured from blood collection. For a Hd in the range of 3 to 30 percent, we find that Hs/Hd is about .83 for a gap of 4.1 μm. When the discharge hematocrit is 30 percent, the ratio decreases to .66 as the gap approaches 7 μm and then increases as the gap becomes thicker. The results indicate that the hematocrit ratio for a gap thicker than 4.1 μm is an increasing function of the discharge hematocrit. The value of Hs/Hd found for the sheet flow models and its dependence on Hd are comparable to those of circular tubes when their diameter equals the gap thickness.
Skip Nav Destination
Article navigation
February 1989
Research Papers
The Fahraeus Effect in Sheet Flows With a Gap Thickness of 4 to 36 μm
L. H. Deng,
L. H. Deng
Biomechanics Institute, Chongqing University, Chongqing, Sichuan, China
Search for other works by this author on:
Y. P. Wu,
Y. P. Wu
Biomechanics Institute, Chongqing University, Chongqing, Sichuan, China
Search for other works by this author on:
G. R. Wang,
G. R. Wang
Biomechanics Institute, Chongqing University, Chongqing, Sichuan, China
Search for other works by this author on:
R. F. Yang,
R. F. Yang
Biomechanics Institute, Chongqing University, Chongqing, Sichuan, China
Search for other works by this author on:
J. S. Lee
J. S. Lee
Department of Biomedical Engineering, University of Virginia, Charlottesville, Va. 22908
Search for other works by this author on:
L. H. Deng
Biomechanics Institute, Chongqing University, Chongqing, Sichuan, China
Y. P. Wu
Biomechanics Institute, Chongqing University, Chongqing, Sichuan, China
G. R. Wang
Biomechanics Institute, Chongqing University, Chongqing, Sichuan, China
R. F. Yang
Biomechanics Institute, Chongqing University, Chongqing, Sichuan, China
J. S. Lee
Department of Biomedical Engineering, University of Virginia, Charlottesville, Va. 22908
J Biomech Eng. Feb 1989, 111(1): 32-36 (5 pages)
Published Online: February 1, 1989
Article history
Received:
October 24, 1987
Revised:
October 20, 1988
Online:
June 12, 2009
Citation
Deng, L. H., Wu, Y. P., Wang, G. R., Yang, R. F., and Lee, J. S. (February 1, 1989). "The Fahraeus Effect in Sheet Flows With a Gap Thickness of 4 to 36 μm." ASME. J Biomech Eng. February 1989; 111(1): 32–36. https://doi.org/10.1115/1.3168336
Download citation file:
Get Email Alerts
Cited By
Related Articles
Frictional Characteristics of Erythrocytes on Coated Glass Plates Subject to Inclined Centrifugal Forces
J Biomech Eng (October,2008)
Blood Freezing to Nearly Absolute Zero Temperature: −272.29°C
J Biomech Eng (February,1981)
Mixing Efficiency of Red Blood Cells With Magnetic Microspheres for a Hybrid Separation System
J. Med. Devices (September,2008)
Measuring the Mechanical Properties of Individual Human Blood Cells
J Biomech Eng (November,1993)
Related Proceedings Papers
Related Chapters
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices
Two-Dimension Simulation of a Red Blood Cell Partitioning in Microvascular Bifurcation
International Conference on Software Technology and Engineering (ICSTE 2012)
Two Advanced Methods
Applications of Mathematical Heat Transfer and Fluid Flow Models in Engineering and Medicine