Increased functionality of microelectronic packages for commercial applications leads to the necessity of identifying packaging solutions with high standards for thermal performance, during its functioning lifetime as well as during various test conditions. A detailed numerical analysis examines the thermal characteristics of a power amplifier module for time division multiple access (TDMA), using commercially available software. The increasing trend in power levels and densities leads to the need of design thermal optimization, either at module level or system level. Under specific test conditions, the thermal performance of the module degrades gradually; therefore, alternative test designs are investigated for thermal performance optimization. Initial study focuses on assessing the thermal performance of a baseline design. The peak temperature reaches 144°C, about 60°C temperature increase over the reference temperature. The peak temperature value is below the limit of 150°C. Further investigation focuses on several systems level designs, by incorporating individual test contactors between the DUT and load board or with conductive elastomers or pedestal solid ground slug for thermal performance enhancement. The peak temperatures are calculated in this case for the system being exposed to the ambient at 85°C. The results indicate that the test design with solid ground slug provides the best thermal performance, ∼ 5% better than the other designs. The small difference between the first two designs (with individual contactors and separate solid ground slug with conductive elastomer) resides in the fact that the elastomer has a small thickness (0.25mm), thus a low thermal resistance (based on thermal conductivity greater than 1W/mK), with minimal impact on the overall thermal performance of the TDMA under current test conditions. The temperature difference between the top section of the contactor designs with the CBC pin/copper block/pedestal is small; in spite of this, the high temperature reached by the individual CBC pins induces possible failures in the elastomer. The designs with pedestal and solid ground slugs have a notable advantage over the design with individual contactors, due to no moving parts within the elastomer, being more robust. The peak temperature reached by the module under the best/worst testing scenarios varies by ∼ 4–5%.
Skip Nav Destination
ASME 2003 International Electronic Packaging Technical Conference and Exhibition
July 6–11, 2003
Maui, Hawaii, USA
Conference Sponsors:
- Electronic and Photonic Packaging Division
ISBN:
0-7918-3690-8
PROCEEDINGS PAPER
System and Package Level Thermal Optimization of Power Amplifier Modules With Application in Wireless Communication
Victor Adrian Chiriac,
Victor Adrian Chiriac
Motorola, Inc., Tempe, AZ
Search for other works by this author on:
Tien-Yu Tom Lee,
Tien-Yu Tom Lee
Motorola, Inc., Tempe, AZ
Search for other works by this author on:
David Lutz
David Lutz
Motorola, Inc., Tempe, AZ
Search for other works by this author on:
Victor Adrian Chiriac
Motorola, Inc., Tempe, AZ
Tien-Yu Tom Lee
Motorola, Inc., Tempe, AZ
David Lutz
Motorola, Inc., Tempe, AZ
Paper No:
IPACK2003-35216, pp. 443-450; 8 pages
Published Online:
January 5, 2009
Citation
Chiriac, VA, Lee, TT, & Lutz, D. "System and Package Level Thermal Optimization of Power Amplifier Modules With Application in Wireless Communication." Proceedings of the ASME 2003 International Electronic Packaging Technical Conference and Exhibition. 2003 International Electronic Packaging Technical Conference and Exhibition, Volume 2. Maui, Hawaii, USA. July 6–11, 2003. pp. 443-450. ASME. https://doi.org/10.1115/IPACK2003-35216
Download citation file:
5
Views
0
Citations
Related Proceedings Papers
Related Articles
Thermal Interfacing Techniques for Electronic Equipment—A Perspective
J. Electron. Packag (June,2003)
Thermal Performance Optimization of Radio Frequency Packages for Wireless Communication
J. Electron. Packag (December,2004)
Nanothermal Interface Materials: Technology Review and Recent Results
J. Electron. Packag (December,2015)
Related Chapters
Section III: Subsections NC and ND — Class 2 and 3 Components
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 1, Fourth Edition
On the Exact Analysis of Non-Coherent Fault Trees: The ASTRA Package (PSAM-0285)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
A Bayesian Approach to Setting Equipment Performance Criteria (PSAM-0438)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)