The connected control method (CCM) is a vibration control strategy that uses damping devices between adjacent dynamic systems to impart dissipative forces upon one another for mitigating their fundamental resonant vibrations. CCM was originally conceived for civil applications to mitigate the resonant vibrations of adjacent high-rise buildings from seismic and wind excitations. This paper examines CCM as a potential vibration control strategy for mechanical applications, particularly for the case of adjacent base isolation systems. These systems typically have lightly damped fundamental resonant frequencies to provide effective isolation at the higher frequencies. The conventional approach to reduce the vibrations of these fundamental resonances is to add damping to the isolators, but at the expense of degraded isolation. For cases when the two or more base isolation systems are adjacent to each other, it is possible to apply CCM to mitigate their fundamental resonant vibrations by interconnecting them with damping devices. This paper first reviews the basic theory of CCM for adjacent one degree of freedom (DOF) mass-spring systems connected by a viscous damper, followed by analytical modeling and optimization of adjacent 6-DOF mass-spring systems connected by viscous dampers. In addition, experimental results using simplified base isolation systems connected by Taylor Devices viscous dampers are also presented to demonstrate the effectiveness of CCM. Results show that CCM can effectively reduce the resonant vibrations of adjacent base isolation systems without degrading the isolation effectiveness as long as their fundamental resonances are sufficiently separated.
Skip Nav Destination
ASME 2014 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference
August 17–20, 2014
Buffalo, New York, USA
Conference Sponsors:
- Design Engineering Division
- Computers and Information in Engineering Division
ISBN:
978-0-7918-4641-4
PROCEEDINGS PAPER
Reducing Resonant Vibrations of Adjacent Base Isolation Systems Using Connected Control Method
Rui M. Botelho,
Rui M. Botelho
General Dynamics Electric Boat, Groton, CT
Search for other works by this author on:
Richard E. Christenson
Richard E. Christenson
University of Connecticut, Storrs, CT
Search for other works by this author on:
Rui M. Botelho
General Dynamics Electric Boat, Groton, CT
Richard E. Christenson
University of Connecticut, Storrs, CT
Paper No:
DETC2014-35515, V008T11A098; 9 pages
Published Online:
January 13, 2015
Citation
Botelho, RM, & Christenson, RE. "Reducing Resonant Vibrations of Adjacent Base Isolation Systems Using Connected Control Method." Proceedings of the ASME 2014 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference. Volume 8: 26th Conference on Mechanical Vibration and Noise. Buffalo, New York, USA. August 17–20, 2014. V008T11A098. ASME. https://doi.org/10.1115/DETC2014-35515
Download citation file:
11
Views
0
Citations
Related Proceedings Papers
Related Articles
A Comparative Study and Analysis of Semi-Active Vibration-Control Systems
J. Vib. Acoust (October,2002)
Virtual Skyhook Vibration Isolation System
J. Vib. Acoust (January,2002)
Identification of a Dynamic System Using Ambient Vibration Measurements
J. Appl. Mech (December,1998)
Related Chapters
Smart Semi-Active Control of Floor-Isolated Structures
Intelligent Engineering Systems Through Artificial Neural Networks, Volume 17
An Adaptive Fuzzy Control for a Multi-Degree-of-Freedom System
Intelligent Engineering Systems Through Artificial Neural Networks, Volume 17
Research on Autobody Panels Developmental Technology Based on Reverse Engineering
Proceedings of the 2010 International Conference on Mechanical, Industrial, and Manufacturing Technologies (MIMT 2010)