A new multi-physics finite element model (FEM) on the vibration of the radial artery on the wrist is built by this study to predict vibration of wrist artery vessel vibration and then diastolic and systolic blood pressures. The FEM includes the sensor of gel capsule and strain-sensing electrodes, skin, bones and muscles. The vibrations of skin surface and the sensor module are successfully simulated by the established FEM. The resulted vibratory deformation of the sensor electrodes are further transformed to resistance variations to mimic realistic electronics of the front-end readout circuit via establishing a cross-discipline sub-FEM model. The established FEM can is particularly customized to varied ages, weights, heights, genders, and special cardiovascular diseases of users. The customization can be performed in a fashion of one-time calibration by medical staff and/or medical staff. With the customized FEM in high accuracy level, the diastolic and systolic pressures can be accurately predicted by the simulated output resistance variation. Based on simulation FEMs, the design of the pulse sensor is successfully optimized via the processes of Taguchi and numerical methods. The measurements are also conducted to a dozen of subjects. It shows that the designed novel blood pressure sensor is capable of sensing the blood pressure to require accuracy level of the error less than 10% as compared to commercial counterparts with a cumbersome cuff.
Skip Nav Destination
ASME 2014 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference
August 17–20, 2014
Buffalo, New York, USA
Conference Sponsors:
- Design Engineering Division
- Computers and Information in Engineering Division
ISBN:
978-0-7918-4641-4
PROCEEDINGS PAPER
Optimal Design and Experimental Validation of a New No-Cuff Blood Pressure Sensor Based on a New Finite Element Model
Tse-Yi Tu,
Tse-Yi Tu
National Chiao Tung University, Hsinchu, Taiwan
Search for other works by this author on:
Paul C.-P. Chao,
Paul C.-P. Chao
National Chiao Tung University, Hsinchu, Taiwan
Search for other works by this author on:
Yung-Pin Lee,
Yung-Pin Lee
MedSense Inc., Hsinchu County, Taiwan
Search for other works by this author on:
Yung-Hua Kao
Yung-Hua Kao
National Chiao Tung University, Hsinchu, Taiwan
Search for other works by this author on:
Tse-Yi Tu
National Chiao Tung University, Hsinchu, Taiwan
Paul C.-P. Chao
National Chiao Tung University, Hsinchu, Taiwan
Yung-Pin Lee
MedSense Inc., Hsinchu County, Taiwan
Yung-Hua Kao
National Chiao Tung University, Hsinchu, Taiwan
Paper No:
DETC2014-35552, V008T11A014; 5 pages
Published Online:
January 13, 2015
Citation
Tu, T, Chao, PC, Lee, Y, & Kao, Y. "Optimal Design and Experimental Validation of a New No-Cuff Blood Pressure Sensor Based on a New Finite Element Model." Proceedings of the ASME 2014 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference. Volume 8: 26th Conference on Mechanical Vibration and Noise. Buffalo, New York, USA. August 17–20, 2014. V008T11A014. ASME. https://doi.org/10.1115/DETC2014-35552
Download citation file:
12
Views
0
Citations
Related Proceedings Papers
Related Articles
Distance Measuring Device Over Body Surface
J. Med. Devices (June,2009)
An Ultraminiature MEMS Pressure Sensor With High Sensitivity for Measurement of Intramuscular Pressure (IMP) in Patients With Neuromuscular Diseases
J. Med. Devices (September,2009)
Evolution of a Non-Invasive Method for Providing Assistance to the Heart
J. Med. Devices (June,2009)
Related Chapters
Health and Safety and Emergency Response
Pipeline Transportation of Carbon Dioxide Containing Impurities
Microstructure Evolution and Physics-Based Modeling
Ultrasonic Welding of Lithium-Ion Batteries
Subsection NB—Class 1 Components
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 1, Third Edition