This study has successfully demonstrated a novel tensile testing approach to mount a thin film test specimen onto a MEMS instrument using microfabrication processes. The MEMS instrument consists of a thermal actuator, differential capacitance sensor, and supporting spring. The thermal actuator applies a tensile load on the test specimen to characterize the Young’s modulus and the residual stress of the thin film. As compare with the existing approaches, the problems and difficulties resulting from the alignment and assembly of a thin film test specimen with the testing instrument can be prevented. Furthermore, the parylene passivation technique with the MEMS fabrication process allows the user to change the test materials easily. In application, the present approach has been employed to determine the Young’s modulus and the residual stress of Au and Al films.
Skip Nav Destination
ASME 2008 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference
August 3–6, 2008
Brooklyn, New York, USA
Conference Sponsors:
- Design Engineering Division and Computers in Engineering Division
ISBN:
978-0-7918-4328-4
PROCEEDINGS PAPER
A Novel Micro Tensile Testing Instrument With Replaceable Testing Specimen of Gold and Aluminum by Parylene Passivation Technique
Yung-Dong Lau,
Yung-Dong Lau
National Tsing Hua University, Hsinchu, Taiwan
Search for other works by this author on:
Hong Hocheng,
Hong Hocheng
National Tsing Hua University, Hsinchu, Taiwan
Search for other works by this author on:
Rongshun Chen,
Rongshun Chen
National Tsing Hua University, Hsinchu, Taiwan
Search for other works by this author on:
Weileun Fang
Weileun Fang
National Tsing Hua University, Hsinchu, Taiwan
Search for other works by this author on:
Yung-Dong Lau
National Tsing Hua University, Hsinchu, Taiwan
Hong Hocheng
National Tsing Hua University, Hsinchu, Taiwan
Rongshun Chen
National Tsing Hua University, Hsinchu, Taiwan
Weileun Fang
National Tsing Hua University, Hsinchu, Taiwan
Paper No:
DETC2008-49846, pp. 743-747; 5 pages
Published Online:
July 13, 2009
Citation
Lau, Y, Hocheng, H, Chen, R, & Fang, W. "A Novel Micro Tensile Testing Instrument With Replaceable Testing Specimen of Gold and Aluminum by Parylene Passivation Technique." Proceedings of the ASME 2008 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference. Volume 4: 20th International Conference on Design Theory and Methodology; Second International Conference on Micro- and Nanosystems. Brooklyn, New York, USA. August 3–6, 2008. pp. 743-747. ASME. https://doi.org/10.1115/DETC2008-49846
Download citation file:
4
Views
Related Proceedings Papers
Related Articles
An Ultraminiature MEMS Pressure Sensor With High Sensitivity for Measurement of Intramuscular Pressure (IMP) in Patients With Neuromuscular Diseases
J. Med. Devices (September,2009)
Statistical Characterization of Ultrasonic Additive Manufacturing Ti/Al Composites
J. Eng. Mater. Technol (October,2010)
Modeling-Simulation and Analysis of MEMS Capacitive Millibar Pressure Sensor
J. Nanotechnol. Eng. Med (November,2010)
Related Chapters
Surface Analysis and Tools
Tribology of Mechanical Systems: A Guide to Present and Future Technologies
The Nuclear and Related Industry
Decommissioning Handbook
Orthogonal Polynomial and Treatment Quantification for Missing Data
Taguchi Methods: Benefits, Impacts, Mathematics, Statistics and Applications