This study aims at the design, implementation, and verification of a near infrared (NIR) diffuse optical tomography (DOT) electro-optical imaging system based on a measuring instrument with scanning mechanism of synchronous multi-point detection and an image reconstruction scheme implemented on an off-line PC. The developed measurement instrument possesses a high degree of angular resolution and can be operated in a continuous-intensity or intensity modulation scheme to acquire output NIR radiance signals. Experimental trials are conducted using both homogeneous and heterogeneous phantoms made of high-scattering Intralipid. Promising results have been obtained with a superior spatial resolution, especially for absorption image, compared with the system with fixed number of detection channels.
Skip Nav Destination
ASME 2008 3rd Frontiers in Biomedical Devices Conference
June 18–20, 2008
Irvine, California, USA
Conference Sponsors:
- Nanotechnology Institute
ISBN:
0-7918-4833-7
PROCEEDINGS PAPER
Rotational Scanning Mechanism of Multi-Point Synchronous Detection for Near Infrared Diffuse Optical Tomography
Min-Chun Pan,
Min-Chun Pan
National Central University, Jhongli, Taiwan
Search for other works by this author on:
Chien-Hung Chen,
Chien-Hung Chen
National Central University, Jhongli, Taiwan
Search for other works by this author on:
Lian-Yu Chen,
Lian-Yu Chen
National Central University, Jhongli, Taiwan
Search for other works by this author on:
Min-Cheng Pan
Min-Cheng Pan
Tungnan University, Taipei, Taiwan
Search for other works by this author on:
Min-Chun Pan
National Central University, Jhongli, Taiwan
Chien-Hung Chen
National Central University, Jhongli, Taiwan
Lian-Yu Chen
National Central University, Jhongli, Taiwan
Min-Cheng Pan
Tungnan University, Taipei, Taiwan
Paper No:
BioMed2008-38073, pp. 107-108; 2 pages
Published Online:
June 5, 2009
Citation
Pan, M, Chen, C, Chen, L, & Pan, M. "Rotational Scanning Mechanism of Multi-Point Synchronous Detection for Near Infrared Diffuse Optical Tomography." Proceedings of the ASME 2008 3rd Frontiers in Biomedical Devices Conference. ASME 2008 3rd Frontiers in Biomedical Devices Conference. Irvine, California, USA. June 18–20, 2008. pp. 107-108. ASME. https://doi.org/10.1115/BioMed2008-38073
Download citation file:
1
Views
0
Citations
Related Proceedings Papers
Related Articles
Breast Tumor Detection Instrument Through Mammography Based NIR DOT
J. Med. Devices (June,2010)
Measurement of Solar Radiance Profiles With the Sun and Aureole Measurement System
J. Sol. Energy Eng (November,2013)
Applicability Tests for the Phase Doppler Anemometer for Cavitation Nuclei Measurements
J. Fluids Eng (September,1992)
Related Chapters
The MCRT Method for Participating Media
The Monte Carlo Ray-Trace Method in Radiation Heat Transfer and Applied Optics
Scattering of Out-Plane Line Source Load by a Shallow-Embedded Circular Lining Structure and the Ground Motion
Geological Engineering: Proceedings of the 1 st International Conference (ICGE 2007)
Study on Load Position Switching of Radial Scattering Dispenser
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)