In this paper, we present the design of a novel 3-RUS/RRR redundantly actuated parallel mechanism for ankle rehabilitation based on the principle from the conceptual design. The proposed mechanism can actualize the rotational movements of the ankle in three directions while at the same time the mechanism center of rotations can match the ankle axes of rotations compared with other multi-degree-of-freedom devices, owing to the structural characteristics of the special constraint limb and platform. A new actuator redundancy scheme is used, which not only still maintains all inherent advantages from actuator redundancy but also possesses the kinematic partially decouple feature that improves the flexibility of the robotic system. Kinematic performances, such as dexterity, singularity and stiffness, are analyzed based on the computed Jacobian. Then simulation is performed. All the results show that the redundant robot has no singularity, better dexterity and stiffness within the prescribed workspace in comparison with the corresponding 3-RUS/RRR nonredundant robot, and is suitable for rehabilitation exercise.

FIGURES IN THIS ARTICLE
<>
Copyright © 2013 by ASME
Your Session has timed out. Please sign back in to continue.

References

Sports Medicine, 2012, “Ankle Sprain Rehabilitation,” http://sportsmedicine.about.com/cs/ankle/a/aa051602a.htm
Díaz, I., Gil, J. J., and Sánchez, E., 2011, “Lower-Limb Robotic Rehabilitation: Literature Review and Challenges,” J. Rob. Syst., 2011, 1–11.
Roy, A., Krebs, H. I., Williams, D. J., Bever, C. T., Forrester, L. W., Macko, R. M., and Hogan, N., 2009, “Robot-Aided Neurorehabilitation: A Novel Robot for Ankle Rehabilitation,” IEEE Trans. Rob. Autom., 25(3), pp. 569–582. [CrossRef]
Bharadwaj, K., and Sugar, T. G., 2006, “Kinematics of a Robotic Gait Trainer for Stroke Rehabilitation,” Proceedings of the IEEE International Conference on Robotics and Automation, Orland, FL, pp. 3492–3497.
Blaya, J. A., and Herr, H., 2004, “Adaptive Control of a Variable-Impedance Ankle-Foot Orthoses to Assist Drop-Foot Gait,” IEEE Trans. Neural Syst. Rehabil. Eng., 12(1), pp. 24–31. [CrossRef] [PubMed]
Ding, Y., Sivak, M., Weinberg, B., Mavroidis, C., and Holden, M. K., 2010, “NUVABAT: Northeastern University Virtual Ankle and Balance Trainer,” Proceedings of the IEEE Haptics Symposium, Waltham, Mass, pp. 509–514.
Girone, M., Burdea, G., and Bouzit, M., 1999, “Rutgers Ankle Orthopedic Rehabilitation Interface,” Proc. ASME Dyn. Syst. Control Div., 67, pp. 305–312.
Dai, J. S., and Zhao, T., 2004, “Sprained Ankle Physiotherapy Based Mechanism Synthesis and Stiffness Analysis of a Robotic Rehabilitation Device,” Auton. Rob., 16(2), pp. 207–218. [CrossRef]
Liu, G., Gao, J., Yue, H., Zhang, X., and Lu, G., 2006, “Design and Kinematics Analysis of Parallel Robots for Ankle Rehabilitation,” Proceedings of the IEEE/RSJ International Conference on Intelligent Robots and Systems, Beijing, pp. 253–258.
Saglia, J. A., Tsagarakis, N. G., Dai, J. S., and Caldwell, D. G., 2009, “A High Performance Redundantly Actuated Parallel Mechanism for Ankle Rehabilitation,” Int. J. Robot. Res., 28(9), pp. 1216–1227. [CrossRef]
Tsoi, Y. H., and Xie, S. Q., 2010, “Design and Control of a Parallel Robot for Ankle Rehabilitation,” Int. J. Intell. Syst. Technol. Appl., 8(1), pp. 100–113.
Baldisserri, B., and Parenti-Castelli, V., 2012, “A New 3D Mechanism for Modeling the Passive Motion of the Tibia–Fibula–Ankle Complex,” ASME J. Mech. Rob., 4(2), p. 021004. [CrossRef]
Dettwyler, M., Stacoff, A., Quervain, I. A., and Stussi, E., 2004, “Modelling of Ankle Joint Complex. Reflections With Regards to Ankle Prostheses,” J. Foot Ankle Surg., 10(3), pp. 109–119. [CrossRef]
Sung, E., Slocum, A. H., Ma, R., Bean, J. F., and Culpepper, M. L., 2011, “Design of an Ankle Rehabilitation Device Using Compliant Mechanisms,” ASME J. Med. Devices, 5(1), p. 011001. [CrossRef]
Wu, G., et al. ., 2002, “Letter to Editor: ISB Recommendation on Definitions of Joint Coordinate System of Various Joints for the Reporting of Human Joint Motion—Part I: Ankle, Hip, and Spine,” J. Biomech., 35(4), pp. 543–548. [CrossRef] [PubMed]
Clavel, R., 1990, “Device for the Movement and Positioning of an Element in Space,” U.S. Patent No. 4976582.
Pierrot, F., and Company, O., 1999, “H4: A New Family of 4-DOF Parallel Robots,” Proceedings of the IEEE/ASME on Advanced Intelligent Mechatronics, Atlanta, pp. 508–513.
Wahl, J., 2000, “Articulated Tool Head,” WIPO, WO/2000/025976.
Neumann, K. E., 1988, “Robot,” U.S. Patent No. 4732525.
Gosselin, C., and Hamel, J., 1994, “The Agile Eye: A High–Performance Three-Degree-of-Freedom Camera-Orienting Device,” Proceedings of the IEEE International Conference on Robotics and Automation, San Diego, pp. 781–786.
Gallardo-Alvarado, J., Ramirez-Agundis, A., Rojas-Garduno, H., and Arroyo-Ramirez, B., 2010, “Kinematics of an Asymmetrical Three-Legged Parallel Manipulator by Means of the Screw Theory,” Mech. Mach. Theory, 45(7), pp. 1013–1023. [CrossRef]
Mohamed, M. G., and Duffy, J., 1985, “A Direct Determination of the Instantaneous Kinematics of Fully Parallel Robot Manipulators,” ASME J. Mech. Des., 107(2), pp. 226–229. [CrossRef]
Merlet, J. P., 2006, “Jacobian, Manipulability, Condition Number, and Accuracy of Parallel Robot,” ASME J. Mech. Des., 128(1), pp. 199–206. [CrossRef]
Saglia, J. A., Dai, J. S., and Caldwell, D. G., 2008, “Geometry and Kinematic Analysis of a Redundantly Actuated Parallel Mechanism that Eliminates Singularities and Improves Dexterity,” ASME J. Mech. Des., 130(12), p. 124501. [CrossRef]
Gosselin, C. M., and Angeles, J., 1990, “Singularity Analysis of Closed-Loop Kinematic Chains,” IEEE Trans. Rob. Autom., 6(3), pp. 281–290. [CrossRef]
Joshi, S., and Tsai, L. W., 2003, “A Comparison Study of Two 3-DOF Parallel Manipulators: One With Three and the Other With Four Supporting Limbs,” IEEE Trans. Rob. Autom., 19(2), pp. 200–209. [CrossRef]
Sadjadian, H., and Taghirad, H. D., 2006, “Kinematic, Singularity and Stiffness Analysis of the Hydraulic Shoulder: A 3 DOF Redundant Parallel Manipulator,” Adv. Rob., 20(7), pp. 763–781. [CrossRef]
Li, Y., and Xu, Q., 2008, “Stiffness Analysis for a 3-PUU Parallel Kinematic Machine,” Mech. Mach. Theory, 43(2), pp. 186–200. [CrossRef]

Figures

Grahic Jump Location
Fig. 1

Ankle joint complex [13]

Grahic Jump Location
Fig. 2

JCS for the ankle complex [17]

Grahic Jump Location
Fig. 3

Design process of the new mechanism: a single spherical joint (a); a serial spherical mechanism with arbitrary axes (b), orthogonal axes (c), orthogonal axes with symmetrical structure (d)

Grahic Jump Location
Fig. 4

3D model of the redundant rehabilitation robot: (a) 3D view and (b) front view

Grahic Jump Location
Fig. 5

Geometrical model of the mechanism

Grahic Jump Location
Fig. 6

The available workspace of the redundant manipulator

Grahic Jump Location
Fig. 7

The distribution of dexterity for the nonredundant (a) and redundant (b) in the plane of γ = 0 deg; the nonredundant (c) and redundant (d) within the whole prescribed workspace

Grahic Jump Location
Fig. 8

Regions close to singularity with condition number >1000 for the nonredundant manipulator

Grahic Jump Location
Fig. 9

The distribution of the maximum eigenvalues for the nonredundant (a) and redundant (b) in the plane of γ = 0 deg; the distribution of the minimum eigenvalues for the nonredundant (c) and redundant (d) in the plane of γ = 0 deg

Grahic Jump Location
Fig. 10

Platform orientation (a) and torque (b) curves; one actuator torque for the redundant manipulator (c) and the nonredundant manipulator (d)

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In